Javascript must be enabled to continue!
Effective Utilization of Laboratory Information System to Triage Troponin Critical Value Notification to the Emergency Department
View through CrossRef
Abstract
Objectives
The laboratory received a request to report abnormal troponin (ab-TnI) as critical values (CVs) for ED patients. The laboratory information system (LIS) was programmed to identify only ED patients presenting with an ab-TnI. Only the first ab-TnI on presentation was critical. Unnecessary laboratory CV communications could impair overall turnaround time.
Methods
Mean troponin, ab-TnI test volumes, and ab-TnI from ED patients with suspected acute coronary syndrome were determined. The LIS team constructed a best practice alert in the Beaker module (EPIC, Verona, WI). The ab-TnI CV build filtered patients based on ab-TnI values and ED location. Based on pilot data, the build was adjusted to limit ab-TnI alerts to only the first ab-TnI result. The amended build logic was to trigger the alert if an ED location TnI was abnormal. At trigger, if the lowest TnI result in the last 24 hours is ≤0.040, the return “true.” If true, then no TnI >0.040 in the last 24 hours, call the ED because they currently have a result >0.040. If the answer is “false,” then do not call the ED. If the patient had no TnI in the last 24 hours, then the alert would be triggered as well. The system was piloted after education to the ED and laboratory teams.
Results
The mean TnI per day was 150; the mean ab-TnI was 63 (42%), of which 1.1 ab-TnI originated from the ED. After pilot go-live, the actual number of ab-TnI/day was 14.3. The alert logic was amended to limit the trigger to the first ab-TnI result, reducing the CV volume to 9.6/day.
Conclusion
The LIS can be leveraged to develop a clinically valuable and operationally manageable critical value alert system. Clinical and laboratory teams must be open to amending the process as needed to achieve success.
Oxford University Press (OUP)
Title: Effective Utilization of Laboratory Information System to Triage Troponin Critical Value Notification to the Emergency Department
Description:
Abstract
Objectives
The laboratory received a request to report abnormal troponin (ab-TnI) as critical values (CVs) for ED patients.
The laboratory information system (LIS) was programmed to identify only ED patients presenting with an ab-TnI.
Only the first ab-TnI on presentation was critical.
Unnecessary laboratory CV communications could impair overall turnaround time.
Methods
Mean troponin, ab-TnI test volumes, and ab-TnI from ED patients with suspected acute coronary syndrome were determined.
The LIS team constructed a best practice alert in the Beaker module (EPIC, Verona, WI).
The ab-TnI CV build filtered patients based on ab-TnI values and ED location.
Based on pilot data, the build was adjusted to limit ab-TnI alerts to only the first ab-TnI result.
The amended build logic was to trigger the alert if an ED location TnI was abnormal.
At trigger, if the lowest TnI result in the last 24 hours is ≤0.
040, the return “true.
” If true, then no TnI >0.
040 in the last 24 hours, call the ED because they currently have a result >0.
040.
If the answer is “false,” then do not call the ED.
If the patient had no TnI in the last 24 hours, then the alert would be triggered as well.
The system was piloted after education to the ED and laboratory teams.
Results
The mean TnI per day was 150; the mean ab-TnI was 63 (42%), of which 1.
1 ab-TnI originated from the ED.
After pilot go-live, the actual number of ab-TnI/day was 14.
3.
The alert logic was amended to limit the trigger to the first ab-TnI result, reducing the CV volume to 9.
6/day.
Conclusion
The LIS can be leveraged to develop a clinically valuable and operationally manageable critical value alert system.
Clinical and laboratory teams must be open to amending the process as needed to achieve success.
Related Results
Improving emergency department triage quality improvement project
Improving emergency department triage quality improvement project
Background: Healthcare presents challenges that require nursing professionals to continually evaluate their practice. Overcrowding in the emergency department (ED) has become a wor...
Additional PKA phosphorylation sites in human cardiac troponin I
Additional PKA phosphorylation sites in human cardiac troponin I
We used mass spectrometry to monitor cAMP‐dependent protein kinase catalysed phosphorylation of human cardiac troponin I in vitro. Phosphorylation of isolated troponin I by cAMP‐de...
Structural dynamics of the intrinsically disordered linker region of cardiac troponin T
Structural dynamics of the intrinsically disordered linker region of cardiac troponin T
ABSTRACT
The cardiac troponin complex, composed of troponins I, T, and C, plays a central role in regulating the calcium-dependent interactions between myosin and t...
Phosphorylation of troponin and the effects of interactions between the components of the complex
Phosphorylation of troponin and the effects of interactions between the components of the complex
1. The troponin complex from skeletal muscle contains approximately 1 mol of phosphate/80000g of complex, covalently bound to the troponin T component. 2. On prolonged incubation o...
Referral to geriatric rehabilitation
Referral to geriatric rehabilitation
Summary
Older hospital patients are vulnerable to adverse outcomes of hospital stay. In aging societies,
post-acute care (PAC) programs were developed to support functional
recov...
Factors Associated with Patient Triage Accuracy in the Emergency Department
Factors Associated with Patient Triage Accuracy in the Emergency Department
Triage in the Emergency Department (ED) aims to provide timely emergency interventions in accordance with the urgency of the patient's condition. Triage decisions may be related to...
Do prehospital providers and emergency nurses agree on triage assignment?: an efficacy study
Do prehospital providers and emergency nurses agree on triage assignment?: an efficacy study
ObjectivesThe aim of this study was to investigate the agreement on triage level between prehospital providers and emergency department (ED) nurses in clinical practice when using ...
Analysis of the causes of discrepancies in troponin I concentrations as measured by ARCHITECT High-Sensitive Troponin I ST and STACIA CLEIA cTnI
Analysis of the causes of discrepancies in troponin I concentrations as measured by ARCHITECT High-Sensitive Troponin I ST and STACIA CLEIA cTnI
Background
Recently developed reagents for the highly sensitive measurement of cardiac troponin I are useful for early diagnosis of acute coronary syndrome. How...

