Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Valvuloplasty Balloon Catheter Sizing Approach for Calcified Aortic Valve with Different Annulus Ratios

View through CrossRef
Transcatheter aortic valve implantation (TAVI) is re- garded as the option of preference minimally invasive intervention to treat high-risk patients with aortic steno- sis, which is a common heart valve disease charac- terized by the narrowing of the valve opening due to the thickening of the valve leaflets. During TAVI, a prosthetic aortic valve, replacing the diseased native valve with its function, is inserted and expanded by a balloon catheter if it is a balloon-expandable device. As a result, the correct size of the prosthetic device is vital due to its association with potential complications such as paravalvular regurgitation and aortic annulus rupture [1]. Pre-operative annulus size measurement based on imaging techniques is commonly applied be- fore TAVI procedure including transthoracic echocar- diography, transesophageal echocardiography and multi- detector computed tomography [2], [3]. However, these techniques face two major limitations: heavy dependence on the operator’s experience and the influence of the optimum instant in the cardiac cycle for evaluation. In addition, the potential changes in the annular geometry caused by balloon aortic valvuloplasty, which uses a balloon catheter to dilate the calcified aortic leaflets as a bridge treatment to TAVI, are not considered. There- fore, intraoperative assessments based on valvuloplasty balloon catheters were introduced, which measure the annulus size by the balloon when it is inflated for dilatation [4]. They do, however, only provide limited compatibility for a limited number of devices. This study proposes an intra-operative method for mea- suring the aortic annulus that account for compliance and elliptical geometries using balloon internal pressure and volume data. The valvuloplasty balloon catheter from a commercially available source was used to obtain the intra-balloon pressure-volume curves by an inflation device. A characterized analytical model and a numeri- cal model for balloon free-inflation were used to develop a sizing algorithm for estimating annulus dimensions.
Title: Valvuloplasty Balloon Catheter Sizing Approach for Calcified Aortic Valve with Different Annulus Ratios
Description:
Transcatheter aortic valve implantation (TAVI) is re- garded as the option of preference minimally invasive intervention to treat high-risk patients with aortic steno- sis, which is a common heart valve disease charac- terized by the narrowing of the valve opening due to the thickening of the valve leaflets.
During TAVI, a prosthetic aortic valve, replacing the diseased native valve with its function, is inserted and expanded by a balloon catheter if it is a balloon-expandable device.
As a result, the correct size of the prosthetic device is vital due to its association with potential complications such as paravalvular regurgitation and aortic annulus rupture [1].
Pre-operative annulus size measurement based on imaging techniques is commonly applied be- fore TAVI procedure including transthoracic echocar- diography, transesophageal echocardiography and multi- detector computed tomography [2], [3].
However, these techniques face two major limitations: heavy dependence on the operator’s experience and the influence of the optimum instant in the cardiac cycle for evaluation.
In addition, the potential changes in the annular geometry caused by balloon aortic valvuloplasty, which uses a balloon catheter to dilate the calcified aortic leaflets as a bridge treatment to TAVI, are not considered.
There- fore, intraoperative assessments based on valvuloplasty balloon catheters were introduced, which measure the annulus size by the balloon when it is inflated for dilatation [4].
They do, however, only provide limited compatibility for a limited number of devices.
This study proposes an intra-operative method for mea- suring the aortic annulus that account for compliance and elliptical geometries using balloon internal pressure and volume data.
The valvuloplasty balloon catheter from a commercially available source was used to obtain the intra-balloon pressure-volume curves by an inflation device.
A characterized analytical model and a numeri- cal model for balloon free-inflation were used to develop a sizing algorithm for estimating annulus dimensions.

Related Results

AORTIC ROOT ANEURYSM OR ECTASIA TREATED WITH AORTIC ROOT WRAPPED PROCEDURE
AORTIC ROOT ANEURYSM OR ECTASIA TREATED WITH AORTIC ROOT WRAPPED PROCEDURE
Objectives To develop a relatively simple and effective and less risk operation, aortic root wrapped procedure, to treat with aortic root aneurysm or ectasia. ...
Valve-Sparing Aortic Root Replacement by Congenital Heart Surgeons: A Single Center Experience.
Valve-Sparing Aortic Root Replacement by Congenital Heart Surgeons: A Single Center Experience.
Background Aortic root dilatation and aortic insufficiency can occur in patients with prior conotruncal defect surgery, the Ross procedure, and connective tissue disease (CTD). Val...
Selective aortic arch perfusion: a first-in-human observational cadaveric study
Selective aortic arch perfusion: a first-in-human observational cadaveric study
Abstract Background Selective aortic arch perfusion (SAAP) is a novel endovascular technique that combines thoracic aortic occlusion with extracorpo...
Selective Aortic Arch Perfusion: A First-in-Man Report of a Novel Endovascular Resuscitation Modality
Selective Aortic Arch Perfusion: A First-in-Man Report of a Novel Endovascular Resuscitation Modality
Abstract Background Selective aortic arch perfusion (SAAP) is a novel endovascular technique that combines thoracic aortic occlusion with extracorporeal perfusion of the b...
Prevalence of Patients With Severe Aortic Stenosis, Low Flow And Preserved Ejection Fraction: Results From a Cath-Lab Data Base.
Prevalence of Patients With Severe Aortic Stenosis, Low Flow And Preserved Ejection Fraction: Results From a Cath-Lab Data Base.
AbstractRecent echocardiographic studies described that almost 30% of patients with severe aortic valve stenosis on the basis of aortic valve area may paradoxically have a relative...
P1716 Aorto-left atrial fistula with left atrium dissection
P1716 Aorto-left atrial fistula with left atrium dissection
Abstract We report a 71 year-old female with a history of rheumatic valvulopathy, who underwent St. Jude 23 and St. Jude 21 in ...