Javascript must be enabled to continue!
THE DEFINITION OF AMPERE IS CONFUSING
View through CrossRef
: SI unit of ampere is defined by means of magnetic force between two parallel conductors through which current flows. However, no mention is made of electric force in the opposite direction, which also exists between conductors. For that reason the existing definition is confusing for students, because it leads them to assume that by means of it ampere is also practically realized in laboratory. An analysis of forces shows that under certain conditions the electric force is much smaller than the magnetic force, but that fact still changes the physical picture of the propounded definition. The electric force can be compensated, which should be stated in textbooks when it comes to the definition of ampere, or else mention that ampere is practically realized by the current balance.
International Council on Large Electric Systems - Cigre, Croatian National Committee
Title: THE DEFINITION OF AMPERE IS CONFUSING
Description:
: SI unit of ampere is defined by means of magnetic force between two parallel conductors through which current flows.
However, no mention is made of electric force in the opposite direction, which also exists between conductors.
For that reason the existing definition is confusing for students, because it leads them to assume that by means of it ampere is also practically realized in laboratory.
An analysis of forces shows that under certain conditions the electric force is much smaller than the magnetic force, but that fact still changes the physical picture of the propounded definition.
The electric force can be compensated, which should be stated in textbooks when it comes to the definition of ampere, or else mention that ampere is practically realized by the current balance.
Related Results
Sistem Tapping Fasa Keseimbangan Beban Berbasis Internet of Things
Sistem Tapping Fasa Keseimbangan Beban Berbasis Internet of Things
Load imbalance that occurs continuously will decrease in the reliability of a system, the maximum limit for load imbalance, according to IEEE Std 446-1995 is 20% in each phase. Th...
Monge–Ampère geometry and vortices
Monge–Ampère geometry and vortices
Abstract
We introduce a new approach to Monge–Ampère geometry based on techniques from higher symplectic geometry. Our work is motivated by the application of Monge–...
INFORMASI ARUS DAN SUHU TRAFO 150/20 KV PADA GARDU INDUK SEGOROMADU BERBASIS MIKROKONTROLER DAN SMS
INFORMASI ARUS DAN SUHU TRAFO 150/20 KV PADA GARDU INDUK SEGOROMADU BERBASIS MIKROKONTROLER DAN SMS
Pada operasi penyaluran tenaga listrik Perusahaan Listrik Negara (PLN) menjadi elemen vital yang mutlak dibutuhkan. Tranformator dapat dikatakan jantung tranmisi dan distribusi dal...
Analisis kerusakan motor agitator high shear menggunakan metode kuatitatif
Analisis kerusakan motor agitator high shear menggunakan metode kuatitatif
Motor agitator alat yang digunakan untuk mengkonversi suatu energi listrik menjadi energi mekanik. Alat ini dapat diatur dengan kontrol sistem yaitu inverter agar dapat mengaduk da...
ANALISIS SIFAT MEKANIK PENGELASAN BIMETAL PLAT BAJA KARBON RENDAH DAN STAINLESS STEEL DENGAN LAS GTAW
ANALISIS SIFAT MEKANIK PENGELASAN BIMETAL PLAT BAJA KARBON RENDAH DAN STAINLESS STEEL DENGAN LAS GTAW
Bahan baja tahan karat (stainless steel) banyak digunakan dalam industri rumah tangga maupun industri militer, dan juga dalam industri nuklir. Bahan baja dibag...
Finite type Monge–Ampère foliations
Finite type Monge–Ampère foliations
Abstract
For plurisubharmonic solutions of the complex homogeneous Monge–Ampère equation whose level sets are hypersurfaces of finite type, in dimension 2, it is sho...
Means vs ends: theorizing a definition of human resource development
Means vs ends: theorizing a definition of human resource development
Purpose
The purpose of this paper is to analyze the extant human resource development (HRD) definition research literature and theorizes a new definition of HRD.
Design/methodolo...
Rancang Bangun Tiga Mode Charger Otomatis
Rancang Bangun Tiga Mode Charger Otomatis
Dewasa ini pengguna listrik semakin meningkat, semakin meningkatnya penggunaan listrik maka akan semakin meningkatnya beban. Sumber listrik terbagi dua yaitu AC dan DC. Dalam pengi...