Load imbalance that occurs continuously will decrease in the reliability of a system, the maximum limit for load imbalance, according to IEEE Std 446-1995 is 20% in each phase. The design of a prototype for the management of 1-phase loading electrical energy using the Blynk platform as a user interfaces, monitor and controller. The phase shift method reduces the percentage value of the load imbalance in the electrical energy distribution system. An Energy Meter is used for measuring the electrical quantities and detecting unbalanced phases. Arduino Mega and ESP 8266-01 are used to communicate data as sending and receiving commands from Blynk, testing before balancing the measured load on the Energy Meter. The R phase has a current of 0.36 Ampere, The S phase is 0.71 Ampere, and 0.00 Ampere in the T phase. The percentage before load imbalance shows a value of 100%. After balancing the load, the measured current becomes 0.41 Ampere in the R phase, 0.44 Ampere in the S phase, and the 0.39 Ampere for T phase. The value of the load imbalance decreased to 17.7%.
Institut Teknologi Dirgantara Adisutjipto (IDTA)
Title: Sistem Tapping Fasa Keseimbangan Beban Berbasis Internet of Things
Description:
Load imbalance that occurs continuously will decrease in the reliability of a system, the maximum limit for load imbalance, according to IEEE Std 446-1995 is 20% in each phase.
The design of a prototype for the management of 1-phase loading electrical energy using the Blynk platform as a user interfaces, monitor and controller.
The phase shift method reduces the percentage value of the load imbalance in the electrical energy distribution system.
An Energy Meter is used for measuring the electrical quantities and detecting unbalanced phases.
Arduino Mega and ESP 8266-01 are used to communicate data as sending and receiving commands from Blynk, testing before balancing the measured load on the Energy Meter.
The R phase has a current of 0.
36 Ampere, The S phase is 0.
71 Ampere, and 0.
00 Ampere in the T phase.
The percentage before load imbalance shows a value of 100%.
After balancing the load, the measured current becomes 0.
41 Ampere in the R phase, 0.
44 Ampere in the S phase, and the 0.
39 Ampere for T phase.
The value of the load imbalance decreased to 17.
7%.
Related Results
Rancang Bangun Modul Pembelajaran Transformator 1 Fasa dan 3 Fasa dengan Daya 120/360 VA
Rancang Bangun Modul Pembelajaran Transformator 1 Fasa dan 3 Fasa dengan Daya 120/360 VA
Transformator adalah salah satu komponen penting dalam sistem tenaga listrik. Maka dengan begitu harus adanya pemahaman yang baik mengenai karakteristik transformator. Sehingga per...
PENGUJIAN PEMBANGKITAN TEGANGAN GENERATOR AXIAL-FLUX PERMANENT MAGNET (AFPM) TIGA-FASA GANDA
PENGUJIAN PEMBANGKITAN TEGANGAN GENERATOR AXIAL-FLUX PERMANENT MAGNET (AFPM) TIGA-FASA GANDA
Tulisan ini membahas tentang pembuatan generator axial-flux permanent magnet (AFPM) yang dapat menghasilkan dua buah tegangan tiga-fasa dengan pergesera...
Analisa Pengaruh Tegangan Harmonik Terhadap Regulasi Tegangan Eksitasi Generator Satu Fasa
Analisa Pengaruh Tegangan Harmonik Terhadap Regulasi Tegangan Eksitasi Generator Satu Fasa
Esensinya setiap generator listrik satu fasa maupun tiga fasa telah dilengkapi dengan sistem eksitasi. Sistem eksitasi generator ada tiga, yaitu sistem eksitasi statis, dinamis, da...
GAYA JEPIT UJUNG BALOK UNTUK BERBAGAI TIPE BEBAN DENGAN DEFORMASI GESER
GAYA JEPIT UJUNG BALOK UNTUK BERBAGAI TIPE BEBAN DENGAN DEFORMASI GESER
Momen jepit merupakan gaya yang harus diketahui untuk menghitung gaya-gaya pada suatu struktur. Dalam tulisan ini dibahas pengaruh deformasi geser pada balok terjepit pada kedua uj...
Optimisasi Penjadwalan Pembangkit pada Microgrid dengan Mempertimbangkan Respons Beban
Optimisasi Penjadwalan Pembangkit pada Microgrid dengan Mempertimbangkan Respons Beban
Abstract – In a smart grid, the adequacy of electricity supply is not only determined by generation, but the electrical demand can also be involved. Demand response is one way to m...
Analisis Karakteristik Arus Inrush pada Transformator 3 Fasa dengan Leg yang Berbeda Berbasis Eksperimen
Analisis Karakteristik Arus Inrush pada Transformator 3 Fasa dengan Leg yang Berbeda Berbasis Eksperimen
Fenomena arus inrush merupakan kondisi transformator pada saat pertama kali dihubungkan dengan sumber tegangan dan menghasilkan lonjakan arus yang tinggi. Arus inrush dapat menyeba...
Umjetničko djelo Brede Beban u kontekstu feminističke i postkolonijalne teorije
Umjetničko djelo Brede Beban u kontekstu feminističke i postkolonijalne teorije
I find the key reason in studying this artistic oeuvre in the fact that Breda Beban’s overall oeuvre is less known to the Croatian expert public, and that she has mostly been viewe...
PENGGUNAAN FASA FAILURE RELAY DALAM MENGATASI UNBALANCE VOLTAGE PADA INSTALASI MOTOR TIGA FASA
PENGGUNAAN FASA FAILURE RELAY DALAM MENGATASI UNBALANCE VOLTAGE PADA INSTALASI MOTOR TIGA FASA
Tujuan dari penggunaan fasa failure relay adalah sebagai salah satu modul pembelajaran mahasiswa di Laboratorium Pendidikan Teknik Elektro sebagai pendukung mata kuliah Panel Hubun...