Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Seasonal Particulate Matter (PM10) Concentration in Klang Valley, Malaysia

View through CrossRef
This paper presents a study on Seasonal Particulate Matter (PM10) concentration at selected region in Klang Valley for two years database (2002-2004). The study aimed to analyse on how the distribution of PM10 concentration has changed over monsoonal. Kriging method was employed for interpolating PM10 concentration over limited dataset from seven monitoring stations in Klang Valley. Results found that higher PM10 concentration was recorded during Southwest monsoon (65.92μg/m-3) followed by both inter-monsoon (62.17μg/m-3) and (59.13μg/m-3) respectively. Meanwhile, the lowest concentration (36.67μg/m-3) was recorded during northeast monsoon. From the distribution, Klang station has recorded the highest PM10 concentration throughout the season, followed by Kuala Selangor (59.33μg/m-3). Hulu Langat and Gombak stations have shown the lowest concentration of PM10, (40.92μg/m-3) and (36.67μg/m-3) respectively. The spatial distribution map indicated that the PM10concentration level is not only determining by seasonal but also depends on location of monitoring station itself. The concentration may increase if the station is closer to the proximity of urban and industrial pollution sources.  
Title: Seasonal Particulate Matter (PM10) Concentration in Klang Valley, Malaysia
Description:
This paper presents a study on Seasonal Particulate Matter (PM10) concentration at selected region in Klang Valley for two years database (2002-2004).
The study aimed to analyse on how the distribution of PM10 concentration has changed over monsoonal.
Kriging method was employed for interpolating PM10 concentration over limited dataset from seven monitoring stations in Klang Valley.
Results found that higher PM10 concentration was recorded during Southwest monsoon (65.
92μg/m-3) followed by both inter-monsoon (62.
17μg/m-3) and (59.
13μg/m-3) respectively.
Meanwhile, the lowest concentration (36.
67μg/m-3) was recorded during northeast monsoon.
From the distribution, Klang station has recorded the highest PM10 concentration throughout the season, followed by Kuala Selangor (59.
33μg/m-3).
Hulu Langat and Gombak stations have shown the lowest concentration of PM10, (40.
92μg/m-3) and (36.
67μg/m-3) respectively.
The spatial distribution map indicated that the PM10concentration level is not only determining by seasonal but also depends on location of monitoring station itself.
The concentration may increase if the station is closer to the proximity of urban and industrial pollution sources.
  .

Related Results

Temporal Variation of Ambient PM10 Concentration within an Urban-Industrial Environment
Temporal Variation of Ambient PM10 Concentration within an Urban-Industrial Environment
PM10 concentration in the ambient air has been reported to be the main pollutant affecting human health, particularly in the urban areas. This research is conducted to study the va...
Tobacco smoke-associated particulate matter emissions in a car cabin using the TAPaC platform
Tobacco smoke-associated particulate matter emissions in a car cabin using the TAPaC platform
Zigarettenrauch enthält bis zu 5000 Inhaltsstoffe, von denen mindestens 250 gesundheits-schädlich und 98 krebserregend sind. Der freigesetzte Feinstaub erreicht hohe Konzentrati-on...
A Suitable Model for Spatiotemporal Particulate Matter Concentration Prediction in Rural and Urban Landscapes, Thailand
A Suitable Model for Spatiotemporal Particulate Matter Concentration Prediction in Rural and Urban Landscapes, Thailand
Spatiotemporal particulate matter (PM) concentration prediction using MODIS AOD with significant PM factors in rural and urban landscapes in Thailand is necessary for public health...
Analisis penyebaran Particulate Matter 10 (PM10) pascaerupsi Gunung Kelud 13 Februari 2014
Analisis penyebaran Particulate Matter 10 (PM10) pascaerupsi Gunung Kelud 13 Februari 2014
ABSTRAKErupsi Gunung Kelud terjadi pada 13 Februari 2014 diawali oleh letusan freatomagmatik awal yang diikuti oleh erupsi magmatik yang menghasilkan aliran piroklastik dan jatuhan...
Prediction of PM10 Level During High Particulate Event in Malaysia Using Modified Model
Prediction of PM10 Level During High Particulate Event in Malaysia Using Modified Model
Particulate matter (PM10) is one of the key indicator of air quality index (API) during high particulate event (HPE). PM10 can cause adverse effect on human health and environment;...
Research on the Physicochemical Properties of Fine Particulate Matter in Changchun, Northeast China
Research on the Physicochemical Properties of Fine Particulate Matter in Changchun, Northeast China
Abstract Objective: Air particulate matter concentrations in Changchun City, Jilin Province, may change around the autumn heating day. The aim of this study was to p...
Pengaruh Kondisi Meteorologi Terhadap Kualitas Udara Di Kawasan Penambangan Batu Kapur
Pengaruh Kondisi Meteorologi Terhadap Kualitas Udara Di Kawasan Penambangan Batu Kapur
Particulate Matter 10 (PM10) adalah partikel kecil yang umumnya berdiameter kurang lebih 10 mikrometer. Kondisi meteorologi seperti arah angin, kecepatan angin, suhu dan kelembaban...
A comprehensive study on atmospheric pollution over Ploiesti, Romania
A comprehensive study on atmospheric pollution over Ploiesti, Romania
The accumulation of both particulate matter (PM10, PM2.5) and gaseous species (NO2, CO, SO2, O3) in the atmosphere in urban agglomerations can cause a significant degradation of ai...

Back to Top