Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Hydrology models DRAINMOD and SWIM applied to large soil lysimeters with artificial drainage

View through CrossRef
Two hydrological models, which used different methods to determine the soil water distribution in a soil profile, were evaluated against 4 years of data from large soil lysimeters. SWIM determines soil water distribution from a finite difference implementation of the Richards" equation. DRAINMOD uses a soil-specific relationship between the air volume in a profile and the watertable height to locate the depth to the saturated zone. An ‘equilibrium’ relationship between soil water tension and depth is then assumed to distribute the soil water in the unsaturated zone. Predicted values and measured values for drainage and watertable heights were compared for 3 drainage treatments. The drainage in the lysimeters was achieved by installing an outlet tube on the slowly permeable layer at 0·75 m from the soil surface. The conventional drainage treatment allowed gravity drainage to occur directly from this drainage outlet tube. The other 2 drainage treatments employed controlled drainage, where a step (or weir) is installed in the outlet tube. No drainage can occur from the lysimeters until the water table within the lysimeters reaches the step height. Two different step heights provided 2 controlled drainage treatments. Independently determined model parameters were used without additional calibration for the analysis. Both models performed well. DRAINMOD over-predicted the 4-year cumulative drainage for all treatments, with the largest error being 7%. SWIM conversely under-predicted cumulative drainage, with a maximum error of 16%. The standard error of estimation for the watertable height over the full 4-year data period was lower for SWIM, ranging from 0 ·06 to 0·12 m. DRAINMOD’s standard error over the same period for the watertable height ranged from 0·09 to 0·21 m. Generally, error values from this work were smaller than comparable values from other studies. The hydrology of the lysimeters where there was no lateral inflow, surface runoff, or deep seepage losses, coupled to an essentially 1-dimensional flow domain, probably contributed to the lower errors. Furthermore, limitation of the maximum watertable heights by the controlled drainage regime in the lysimeters also reduces the maximum possible magnitude of the standard error term.
Title: Hydrology models DRAINMOD and SWIM applied to large soil lysimeters with artificial drainage
Description:
Two hydrological models, which used different methods to determine the soil water distribution in a soil profile, were evaluated against 4 years of data from large soil lysimeters.
SWIM determines soil water distribution from a finite difference implementation of the Richards" equation.
DRAINMOD uses a soil-specific relationship between the air volume in a profile and the watertable height to locate the depth to the saturated zone.
An ‘equilibrium’ relationship between soil water tension and depth is then assumed to distribute the soil water in the unsaturated zone.
Predicted values and measured values for drainage and watertable heights were compared for 3 drainage treatments.
The drainage in the lysimeters was achieved by installing an outlet tube on the slowly permeable layer at 0·75 m from the soil surface.
The conventional drainage treatment allowed gravity drainage to occur directly from this drainage outlet tube.
The other 2 drainage treatments employed controlled drainage, where a step (or weir) is installed in the outlet tube.
No drainage can occur from the lysimeters until the water table within the lysimeters reaches the step height.
Two different step heights provided 2 controlled drainage treatments.
Independently determined model parameters were used without additional calibration for the analysis.
Both models performed well.
DRAINMOD over-predicted the 4-year cumulative drainage for all treatments, with the largest error being 7%.
SWIM conversely under-predicted cumulative drainage, with a maximum error of 16%.
The standard error of estimation for the watertable height over the full 4-year data period was lower for SWIM, ranging from 0 ·06 to 0·12 m.
DRAINMOD’s standard error over the same period for the watertable height ranged from 0·09 to 0·21 m.
Generally, error values from this work were smaller than comparable values from other studies.
The hydrology of the lysimeters where there was no lateral inflow, surface runoff, or deep seepage losses, coupled to an essentially 1-dimensional flow domain, probably contributed to the lower errors.
Furthermore, limitation of the maximum watertable heights by the controlled drainage regime in the lysimeters also reduces the maximum possible magnitude of the standard error term.

Related Results

Blunt Chest Trauma and Chylothorax: A Systematic Review
Blunt Chest Trauma and Chylothorax: A Systematic Review
Abstract Introduction: Although traumatic chylothorax is predominantly associated with penetrating injuries, instances following blunt trauma, as a rare and challenging condition, ...
Using multiple hydrological data sources to reduce uncertainty in soil drainage modeling
Using multiple hydrological data sources to reduce uncertainty in soil drainage modeling
<p>Soil drainage flux is crucial for determining agrochemical loading and groundwater recharge. Because soil drainage is difficult to measure, it is typically predict...
Evolution of hydrological sciences from dimensions of object, discipline and methodology
Evolution of hydrological sciences from dimensions of object, discipline and methodology
Abstract. The evolution routes and development stages in hydrological sciences are summarised from the following three dimensions: research object, discipline and methodology, by m...
Drainage reorganization disrupts scaling between drainage area and valley width
Drainage reorganization disrupts scaling between drainage area and valley width
Valley width is a fundamental morphologic property of rivers that plays a key role in drainage networks' hydrology, ecology, and geomorphology. In many cases, defining and measurin...
Safety and effectiveness of transient ascites drainage in hospitalized patients with large ascites
Safety and effectiveness of transient ascites drainage in hospitalized patients with large ascites
Objectives Single paracentesis is the standard treatment for large ascites. An alternative is the placement of a transient ascites drainage. This study aimed to evaluat...
Soil deformation during field traffic
Soil deformation during field traffic
Under moist soil conditions, high wheel loads and repeated wheel passes due to intensive field traffic, e.g. at sugar beet harvest, significantly increase the risk of soil compacti...
Microwave Observations of Soil Hydrology
Microwave Observations of Soil Hydrology
The upper few centimeters of the soil are extremely important because they are the interface between soil science and land-atmosphere research and are also the region of the greate...

Back to Top