Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

ANALISIS VARIASI WINDOW WIDTH TERHADAP INFORMASI CITRA ANATOMI MSCT STONOGRAFI

View through CrossRef
ABSTRACT Background : Multi Slice Computed Tomography is a diagnostic imaging method that can display cross section anatomy in the axial, sagital, and coronal areas. MSCT Stonography imaging both visualizes the anatomy of the urinary tract and stone pathology supported by the presence of ureter tracking techniques and without using contrast media. On this method, the appropriate window width will produce an optimal anatomical picture. The Study aims to determine the effect of window width on anatomical image information on MSCT Stonography. Methods : Type of research is quantitative experimental approach, conducted in January-February 2020 in Hasan Sadikin Bandung hospital, Bandung. Research with variations  in window width 300 HU, 350 HU, 400 HU, 450 HU, and 500 HU on MSCT stonography og 10 patients. Criteria’s patients is patients with clinical kidney stones, willing to be a research sample. Result imagery rated two respondents, include parenchymal kidney, pelvic calices kidney, ureters, vesica urinary, and stones kidney. Then do Kappa test continued testing Friedman to know the highest mean rank and the influence og the window width oh the image og MSCT stonography. Results : Based on the result of the Friedman statistical test overall anatomy obtained significance value (p-value) = 0.000 < 0.05 means that there is an influence of window width value, the contrast resolution will increase and the better the firm boundary, but the resulting image will be more radioluscent. Based on Friedman’s mean rank test result obtained the highest mean rank of 3,54 in a variation of window width 300. The most optical window displays anatomy information using window width 300. Conclussion : There are difference in anatomical image information of MSCT stonography among 5 variation window width on examination MSCT stonography. Window width 300 HU is better at anatomy information on MSCT stonography to show better contrast, crisp sharpness, no blur image.
Title: ANALISIS VARIASI WINDOW WIDTH TERHADAP INFORMASI CITRA ANATOMI MSCT STONOGRAFI
Description:
ABSTRACT Background : Multi Slice Computed Tomography is a diagnostic imaging method that can display cross section anatomy in the axial, sagital, and coronal areas.
MSCT Stonography imaging both visualizes the anatomy of the urinary tract and stone pathology supported by the presence of ureter tracking techniques and without using contrast media.
On this method, the appropriate window width will produce an optimal anatomical picture.
The Study aims to determine the effect of window width on anatomical image information on MSCT Stonography.
Methods : Type of research is quantitative experimental approach, conducted in January-February 2020 in Hasan Sadikin Bandung hospital, Bandung.
Research with variations  in window width 300 HU, 350 HU, 400 HU, 450 HU, and 500 HU on MSCT stonography og 10 patients.
Criteria’s patients is patients with clinical kidney stones, willing to be a research sample.
Result imagery rated two respondents, include parenchymal kidney, pelvic calices kidney, ureters, vesica urinary, and stones kidney.
Then do Kappa test continued testing Friedman to know the highest mean rank and the influence og the window width oh the image og MSCT stonography.
Results : Based on the result of the Friedman statistical test overall anatomy obtained significance value (p-value) = 0.
000 < 0.
05 means that there is an influence of window width value, the contrast resolution will increase and the better the firm boundary, but the resulting image will be more radioluscent.
Based on Friedman’s mean rank test result obtained the highest mean rank of 3,54 in a variation of window width 300.
The most optical window displays anatomy information using window width 300.
Conclussion : There are difference in anatomical image information of MSCT stonography among 5 variation window width on examination MSCT stonography.
Window width 300 HU is better at anatomy information on MSCT stonography to show better contrast, crisp sharpness, no blur image.

Related Results

The use of Green Bean Juice as an Effort to Improve MSCT Image in Abdomen MSCT Protocol (in Vitro Study)
The use of Green Bean Juice as an Effort to Improve MSCT Image in Abdomen MSCT Protocol (in Vitro Study)
Oral contrast media usually used in abdominal MSCT examinations are water and contrast media containing iodine. However, there are advantages and disadvantages, so an alternative r...
ENKRIPSI DAN DEKRIPSI CITRA MENGGUNAKAN METODE FRAKTAL
ENKRIPSI DAN DEKRIPSI CITRA MENGGUNAKAN METODE FRAKTAL
Enkripsi citra dengan metode fraktal adalah proses penyandian yang mengubah citra asli (plain image) menjadi citra yang tidak bisa dimengerti (cipher image) dengan menggunakan citr...
PENGGUNAAN CITRA HIMPUNAN JULIA SEBAGAI CITRA SAMPUL UNTUK MENYEMBUNYIKAN CITRA RAHASIA
PENGGUNAAN CITRA HIMPUNAN JULIA SEBAGAI CITRA SAMPUL UNTUK MENYEMBUNYIKAN CITRA RAHASIA
Steganografi dengan metode fraktal (fractal steganography) adalah teknik menyembunyikan informasi atau pesan, yang dapat berupa citra rahasia, dalam suatu citra sampul (cover image...
Evaluation of MSCT severity scoring for prediction of mortality among patients with COVID-19
Evaluation of MSCT severity scoring for prediction of mortality among patients with COVID-19
Abstract Background Lung CT imaging may reveal COVID-19 abnormalities earlier than RTPCR. CT may be more sensitive than RT-PCR for diagnosing COVID-...
PENGAMANAN CITRA SIDIK JARI MENGGUNAKAN KRIPTOGRAFI DAN STEGANOGRAFI FRAKTAL
PENGAMANAN CITRA SIDIK JARI MENGGUNAKAN KRIPTOGRAFI DAN STEGANOGRAFI FRAKTAL
Banyak data multimedia penting yang bertransmisi di internet, seperti data sidik jari, dan perlu dilakukan pengamanan terhadap data tersebut. Pengamanan citra sidik jari dilakukan ...

Back to Top