Advanced Method of Variable Refrigerant Flow (VRF) Systems Designing to Forecast Onsite Operation—Part 2: Phenomenological Simulation to Recoup Refrigeration Energy

View through CrossRef
This paper focuses on the application of speed-regulated compressors (SRCs) to cover changeable heat loads with high efficiency in conventional air conditioning systems (ACS) as well as in the more advanced variable refrigerant flow (VRF)-type outdoor and indoor ACS. In reality, an SRC is an oversized compressor, although it can operate efficiently at part loads. The higher the level of regulated loads (LRL) of the SRC, the more the compressor is oversized. It is preferable to reduce the size of the SRC by covering the peak loads and recouping the excessive refrigeration energy reserved at decreased actual loads within the range of regulated loads. Therefore, the range of changeable loads is chosen as the object to be narrowed by using the reserved refrigeration capacity. Thus, the general fundamental approach of dividing the overall heat load range of the ACS into the ranges with changeable and unchangeable loads, as previously developed by the authors, is applied for the range of primary changeable loads. Due to this innovative step, the principle of two-stage outdoor air conditioning according to changeable and unchangeable loads, also proposed by the authors, has been extended over the range of primary changeable loads to reduce the level of refrigeration capacity regulation and SRC size. To realize this, part of the changeable load range is offset by the reserved refrigeration capacity, leading to a reduction in the changeable load range and the SRC size by approximately 20% for temperate climatic conditions.
Title: Advanced Method of Variable Refrigerant Flow (VRF) Systems Designing to Forecast Onsite Operation—Part 2: Phenomenological Simulation to Recoup Refrigeration Energy
Description:
This paper focuses on the application of speed-regulated compressors (SRCs) to cover changeable heat loads with high efficiency in conventional air conditioning systems (ACS) as well as in the more advanced variable refrigerant flow (VRF)-type outdoor and indoor ACS.
In reality, an SRC is an oversized compressor, although it can operate efficiently at part loads.
The higher the level of regulated loads (LRL) of the SRC, the more the compressor is oversized.
It is preferable to reduce the size of the SRC by covering the peak loads and recouping the excessive refrigeration energy reserved at decreased actual loads within the range of regulated loads.
Therefore, the range of changeable loads is chosen as the object to be narrowed by using the reserved refrigeration capacity.
Thus, the general fundamental approach of dividing the overall heat load range of the ACS into the ranges with changeable and unchangeable loads, as previously developed by the authors, is applied for the range of primary changeable loads.
Due to this innovative step, the principle of two-stage outdoor air conditioning according to changeable and unchangeable loads, also proposed by the authors, has been extended over the range of primary changeable loads to reduce the level of refrigeration capacity regulation and SRC size.
To realize this, part of the changeable load range is offset by the reserved refrigeration capacity, leading to a reduction in the changeable load range and the SRC size by approximately 20% for temperate climatic conditions.

Related Results

Solar Powered Air-Conditioning Using Absorption Refrigeration Technique
Solar Powered Air-Conditioning Using Absorption Refrigeration Technique
The present work includes design, construction and operates of a prototype solar absorption refrigeration system, using methanol as a refrigerant to avoid any refrigerant that caus...
Air-Conditioning Using Waste Heat Energy
Air-Conditioning Using Waste Heat Energy
Abstract All oil & gas building facilities such as control room, electrical room, substation and personal accommodation etc., require a comfortable indoor condit...
Application and Exploration of Carbon Dioxide R744 as Refrigerant and Secondary Refrigerant in Refrigerating Unit of Commercial Super
Application and Exploration of Carbon Dioxide R744 as Refrigerant and Secondary Refrigerant in Refrigerating Unit of Commercial Super
In this paper, the cascade refrigeration system and the load cooling system of the natural working medium are integrated as one unit system, which can meet the needs of different t...
Cooling capacity of experimental system with natural refrigerant circulation and condenser radiative cooling
Cooling capacity of experimental system with natural refrigerant circulation and condenser radiative cooling
The surface of the Earth is a source of radiation of thermal energy, which, passing through the atmosphere, is partially absorbed while the bulk of the energy is released into the ...
Integration of a grey-box refrigerated case model in EnergyPlus via Python plugin
Integration of a grey-box refrigerated case model in EnergyPlus via Python plugin
Abstract Commercial buildings, in particular grocery stores (due mainly to their large refrigeration load), provide opportunities for energy cost reductions. Grocery stor...
Refrigerant Subcooling Correlations for Different Expansion Devices for a Non-Intrusive Charge Indicator
Refrigerant Subcooling Correlations for Different Expansion Devices for a Non-Intrusive Charge Indicator
The most common problems affecting residential and light commercial heating, ventilation, and air-conditioning (HVAC) systems are slow refrigerant leaks. Equipment users are usuall...
An Alternative Method for the Cooling of Power Microelectronics Using Classical Refrigeration
An Alternative Method for the Cooling of Power Microelectronics Using Classical Refrigeration
Classical refrigeration using vapor compression has been widely applied over the past decades to large-scale industrial systems, with few known applications to the microelectronic ...
Advanced Dual Refrigerant Expansion Cycle for Liquefaction
Advanced Dual Refrigerant Expansion Cycle for Liquefaction
Abstract This paper presents a LNG Liquefaction cycle configuration using two stages of methane expansion and a single stage of nitrogen expansion (Dual Refrigerant)...