Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Diagnosis of left ventricular diastolic dysfunction in the setting of acute changes in loading conditions

View through CrossRef
Abstract Introduction Conventional pulsed wave Doppler parameters are known to be preload dependent, whereas newly proposed Doppler indices may be less influenced by variations in loading conditions. The aim of the present study was to evaluate the effects of haemodialysis-induced preload reduction on both conventional and new Doppler parameters for the assessment of left ventricular (LV) diastolic function. Methods This prospective observational study was conducted in a medical-surgical intensive care unit (ICU) and nephrology department of a teaching hospital. In total, 37 haemodialysis patients with end-stage renal disease (age [mean ± standard deviation]: 52 ± 13 years) and eight ventilated ICU patients with acute renal failure receiving vasopressor therapy (age 57 ± 16 years; Simplified Acute Physiology Score II 51 ± 17) were studied. Echocardiography was performed before and after haemodialysis. Conventional pulsed wave Doppler indices of LV diastolic function as well as new Doppler indices, including Doppler tissue imaging early diastolic velocities (E' wave) of the septal and lateral portions of the mitral annulus, and propagation velocity of LV inflow at early diastole (Vp) were measured and compared before and after ultrafiltration. Results The volume of ultrafiltration was greater in haemodialysis patients than in ICU patients (3.0 ± 1.1 l versus 1.9 ± 0.9 l; P = 0.005). All conventional pulsed wave Doppler parameters were altered by haemodialysis. In haemodialysis patients, E' velocity decreased after ultrafiltration when measured at the septal mitral annulus (7.1 ± 2.5 cm/s versus 5.9 ± 1.7 cm/s; P = 0.0003), but not at its lateral portion (8.9 ± 3.1 cm/s versus 8.3 ± 2.6 cm/s; P = 0.37), whereas no significant variation was observed in ICU patients. Vp decreased uniformly after ultrafiltration, the difference being significant only in haemodialysis patients (45 ± 11 cm/s versus 41 ± 13 cm/s; P = 0.04). Although of less magnitude, ultrafiltration-induced variations in Doppler parameters were also observed in haemodialysis patients with altered LV systolic function. Conclusion In contrast to other Doppler parameters, Doppler tissue imaging E' maximal velocity measured at the lateral mitral annulus represents an index of LV diastolic function that is relatively insensitive to abrupt and marked preload reduction.
Title: Diagnosis of left ventricular diastolic dysfunction in the setting of acute changes in loading conditions
Description:
Abstract Introduction Conventional pulsed wave Doppler parameters are known to be preload dependent, whereas newly proposed Doppler indices may be less influenced by variations in loading conditions.
The aim of the present study was to evaluate the effects of haemodialysis-induced preload reduction on both conventional and new Doppler parameters for the assessment of left ventricular (LV) diastolic function.
Methods This prospective observational study was conducted in a medical-surgical intensive care unit (ICU) and nephrology department of a teaching hospital.
In total, 37 haemodialysis patients with end-stage renal disease (age [mean ± standard deviation]: 52 ± 13 years) and eight ventilated ICU patients with acute renal failure receiving vasopressor therapy (age 57 ± 16 years; Simplified Acute Physiology Score II 51 ± 17) were studied.
Echocardiography was performed before and after haemodialysis.
Conventional pulsed wave Doppler indices of LV diastolic function as well as new Doppler indices, including Doppler tissue imaging early diastolic velocities (E' wave) of the septal and lateral portions of the mitral annulus, and propagation velocity of LV inflow at early diastole (Vp) were measured and compared before and after ultrafiltration.
Results The volume of ultrafiltration was greater in haemodialysis patients than in ICU patients (3.
0 ± 1.
1 l versus 1.
9 ± 0.
9 l; P = 0.
005).
All conventional pulsed wave Doppler parameters were altered by haemodialysis.
In haemodialysis patients, E' velocity decreased after ultrafiltration when measured at the septal mitral annulus (7.
1 ± 2.
5 cm/s versus 5.
9 ± 1.
7 cm/s; P = 0.
0003), but not at its lateral portion (8.
9 ± 3.
1 cm/s versus 8.
3 ± 2.
6 cm/s; P = 0.
37), whereas no significant variation was observed in ICU patients.
Vp decreased uniformly after ultrafiltration, the difference being significant only in haemodialysis patients (45 ± 11 cm/s versus 41 ± 13 cm/s; P = 0.
04).
Although of less magnitude, ultrafiltration-induced variations in Doppler parameters were also observed in haemodialysis patients with altered LV systolic function.
Conclusion In contrast to other Doppler parameters, Doppler tissue imaging E' maximal velocity measured at the lateral mitral annulus represents an index of LV diastolic function that is relatively insensitive to abrupt and marked preload reduction.

Related Results

Hydatid Disease of The Brain Parenchyma: A Systematic Review
Hydatid Disease of The Brain Parenchyma: A Systematic Review
Abstarct Introduction Isolated brain hydatid disease (BHD) is an extremely rare form of echinococcosis. A prompt and timely diagnosis is a crucial step in disease management. This ...
Left ventricular diastolic function and cardiotoxic chemotherapy
Left ventricular diastolic function and cardiotoxic chemotherapy
Abstract Background Left ventricular ejection fraction falls when the myocardium has already lost a significant portion of its functional capacity. ...
Ventilatory efficiency is affected by left ventricular diastolic dysfunction without left ventricular ejection fraction
Ventilatory efficiency is affected by left ventricular diastolic dysfunction without left ventricular ejection fraction
In the past, the cause of heart failure was considered left ventricular systolic dysfunction, however, left ventricular diastolic dysfunction has also attracted attention of the ca...
Left Ventricular diastolic dysfunction among hypertensive patients.
Left Ventricular diastolic dysfunction among hypertensive patients.
Objectives: To assess the occurrence of left ventricular diastolic dysfunction among hypertensive patients on echocardiography. Study Design: Cross Sectional study. Setting: South ...

Back to Top