Predischarge Screening of Neonates with Transcutaneous Bilirubinometer
View through CrossRef
Objective:
To compare the diagnostic accuracy of various transcutaneous bilirubin (TcB) nomograms for predischarge screening.
Methods:
The paired total serum bilirubin (TSB) and TcB measurements collected in neonates ≥35 weeks and ≥2000 g birth weight were analyzed. BiliCare™ bilirubinometer was used for TcB measurement. We chose the following nomograms for the study: Bhutani nomogram, Maisel's nomogram, Agarwal nomogram, Thakkar nomogram, American Academy of Pediatrics (AAP) nomogram within 3 mg/dl of phototherapy cutoff, AAP nomogram >70% of phototherapy cutoff and if TcB value is above 13 mg/dl. The diagnostic accuracy of these nomograms for TcB was compared with TSB plotted in the Bhutani nomogram.
Results:
TcB showed a positive correlation with TSB (Pearson correlation coefficient = 0.783). Bhutani nomogram, Maisel's nomogram and AAP (using within 3 mg/dL cutoff) nomogram showed good sensitivity and low false-negative rate while avoiding blood draws in most neonates.
Conclusion:
Bhutani nomogram, Maisel's nomogram, and AAP (using within 3 mg/dL of phototherapy cutoff) nomograms have comparable diagnostic accuracy for predischarge bilirubin screening in neonates.
Ovid Technologies (Wolters Kluwer Health)
Title: Predischarge Screening of Neonates with Transcutaneous Bilirubinometer
Description:
Objective:
To compare the diagnostic accuracy of various transcutaneous bilirubin (TcB) nomograms for predischarge screening.
Methods:
The paired total serum bilirubin (TSB) and TcB measurements collected in neonates ≥35 weeks and ≥2000 g birth weight were analyzed.
BiliCare™ bilirubinometer was used for TcB measurement.
We chose the following nomograms for the study: Bhutani nomogram, Maisel's nomogram, Agarwal nomogram, Thakkar nomogram, American Academy of Pediatrics (AAP) nomogram within 3 mg/dl of phototherapy cutoff, AAP nomogram >70% of phototherapy cutoff and if TcB value is above 13 mg/dl.
The diagnostic accuracy of these nomograms for TcB was compared with TSB plotted in the Bhutani nomogram.
Results:
TcB showed a positive correlation with TSB (Pearson correlation coefficient = 0.
783).
Bhutani nomogram, Maisel's nomogram and AAP (using within 3 mg/dL cutoff) nomogram showed good sensitivity and low false-negative rate while avoiding blood draws in most neonates.
Conclusion:
Bhutani nomogram, Maisel's nomogram, and AAP (using within 3 mg/dL of phototherapy cutoff) nomograms have comparable diagnostic accuracy for predischarge bilirubin screening in neonates.
Related Results
Non-invasive detection of bilirubin concentrations during the first week of life in a low-resource setting along the Thailand-Myanmar border
Non-invasive detection of bilirubin concentrations during the first week of life in a low-resource setting along the Thailand-Myanmar border
Abstract
Background
Neonatal hyperbilirubinaemia (NH) is a common problem worldwide and causes morbidity and mortality especial...
Correlation of transcutaneous and serum bilirubin levels in late preterm and term neonates at a tertiary care center in south India
Correlation of transcutaneous and serum bilirubin levels in late preterm and term neonates at a tertiary care center in south India
Background
Neonatal jaundice is one of the most prevalent condition during first week of life causing morbidity and even mortality in few, especially in low – middle income countri...
Correlation of transcutaneous and serum bilirubin levels in late preterm and term neonates at a tertiary care center in south India
Correlation of transcutaneous and serum bilirubin levels in late preterm and term neonates at a tertiary care center in south India
Background
Neonatal jaundice is one of the most prevalent conditions during first week of life causing morbidity and even mortality in few, especially in low – middle income countr...
Correlation of transcutaneous and serum bilirubin levels in late preterm and term neonates at a tertiary care center in south India
Correlation of transcutaneous and serum bilirubin levels in late preterm and term neonates at a tertiary care center in south India
Background Neonatal jaundice is one of the most prevalent condition during first week of life causing morbidity and even mortality in few, especially in low – middle income countri...
Comparison of Transcutaneous and Total Serum Bilirubin Measurements in Neonates With Jaundice: A Prospective Study From Nepal
Comparison of Transcutaneous and Total Serum Bilirubin Measurements in Neonates With Jaundice: A Prospective Study From Nepal
Abstract
Background:
Neonatal jaundice is very common (≈ 60% of term and 80% of preterm newborns) and, if severe, can lead to bilirubin neurotoxicity. The gold-sta...
CORRELATION BETWEEN TOTAL SERUM BILIRUBIN LEVELS AND TRANSCUTANEOUS BILIRUBINOMETER VALUES IN NEONATAL JAUNDICE
CORRELATION BETWEEN TOTAL SERUM BILIRUBIN LEVELS AND TRANSCUTANEOUS BILIRUBINOMETER VALUES IN NEONATAL JAUNDICE
Background: Jaundice in newborns is a prevalent postnatal complication, typically benign in nature. To assess neonatal jaundice, the development of non-invasive techniques, such as...
Diagnostic Accuracy of Transcutaneous Bilirubinometry Versus Serum Bilirubin Level
Diagnostic Accuracy of Transcutaneous Bilirubinometry Versus Serum Bilirubin Level
Objective: To assess the diagnostic accuracy of transcutaneous bilirubinometry over serum bilirubin level in newborns with hyperbilirubinemia.
Methodology: This cross-sectional stu...
Does Gender Affect Levels of Hyperbilirubinemia in Term Neonates
Does Gender Affect Levels of Hyperbilirubinemia in Term Neonates
Introduction: Hyperbilirubinemia is a common & in most1cases, benign problem in1first month of1life which is often1physiologic & intervention is not1usually1necessary. In t...