Correlation of transcutaneous and serum bilirubin levels in late preterm and term neonates at a tertiary care center in south India

View through CrossRef
Background Neonatal jaundice is one of the most prevalent conditions during first week of life causing morbidity and even mortality in few, especially in low – middle income countries. Although visual inspection for jaundice has been a time tested method, serum bilirubin is the gold standard investigation of choice. Due to this, newborns receive many heel or vein pricks for testing, hence the transcutaneous bilirubinometer can be a helpful non-invasive tool for diagnosing jaundice requiring phototherapy. Methods This prospective study was carried out in a tertiary care hospital in Mangalore, Karnataka to compare a non invasive method of detecting bilirubin levels and serum bilirubin levels. Performance of a transcutaneous bilirubinometer Dräger Jaundice Meter JM-105 was assessed against routine venous serum bilirubin testing before phototherapy during neonatal care in the first two weeks of life. Results were derived by analysing the correlation coefficient between two methods and direct agreement was analysed using Bland Altman analysis. Results Total of 271 neonates (>35 weeks) were included in the study. Transcutaneous bilirubinometry and serum bilirubin values were done on all of them in the first week of life. Correlation analysis showed significant relationship with a Pearson correlation coefficient of 0.629. Values of transcutaneous bilirubinometer showed excellent agreement with venous serum bilirubin concentration in Bland Altman analysis. Conclusions The transcutaneous bilirubinometer is a reliable tool to screen neonates and identify those needing phototherapy there by reducing invasive blood sampling.
Title: Correlation of transcutaneous and serum bilirubin levels in late preterm and term neonates at a tertiary care center in south India
Description:
Background Neonatal jaundice is one of the most prevalent conditions during first week of life causing morbidity and even mortality in few, especially in low – middle income countries.
Although visual inspection for jaundice has been a time tested method, serum bilirubin is the gold standard investigation of choice.
Due to this, newborns receive many heel or vein pricks for testing, hence the transcutaneous bilirubinometer can be a helpful non-invasive tool for diagnosing jaundice requiring phototherapy.
Methods This prospective study was carried out in a tertiary care hospital in Mangalore, Karnataka to compare a non invasive method of detecting bilirubin levels and serum bilirubin levels.
Performance of a transcutaneous bilirubinometer Dräger Jaundice Meter JM-105 was assessed against routine venous serum bilirubin testing before phototherapy during neonatal care in the first two weeks of life.
Results were derived by analysing the correlation coefficient between two methods and direct agreement was analysed using Bland Altman analysis.
Results Total of 271 neonates (>35 weeks) were included in the study.
Transcutaneous bilirubinometry and serum bilirubin values were done on all of them in the first week of life.
Correlation analysis showed significant relationship with a Pearson correlation coefficient of 0.
629.
Values of transcutaneous bilirubinometer showed excellent agreement with venous serum bilirubin concentration in Bland Altman analysis.
Conclusions The transcutaneous bilirubinometer is a reliable tool to screen neonates and identify those needing phototherapy there by reducing invasive blood sampling.

Related Results

COMPARISON OF BLOOD GLUCOSE LEVEL IN PRETERM AND FULL-TERM BABIES IN 1ST 48 HOURS OF LIFE IN A TERTIARY CARE HOSPITAL
COMPARISON OF BLOOD GLUCOSE LEVEL IN PRETERM AND FULL-TERM BABIES IN 1ST 48 HOURS OF LIFE IN A TERTIARY CARE HOSPITAL
Background: Neonatal glucose regulation is crucial for early metabolic adaptation, particularly in the first 48 hours of life when the transition from intrauterine to extrauterine ...
Umbilical serum concentrations of chemokines (RANTES and MGSA/GRO‐α) in preterm and term neonates
Umbilical serum concentrations of chemokines (RANTES and MGSA/GRO‐α) in preterm and term neonates
AbstractBackground: The objective of this study was to explore the relationship between labor (preterm and term) and umbilical blood serum regulated on activation, normal T cell e...
Correlation of transcutaneous and serum bilirubin levels in late preterm and term neonates at a tertiary care center in south India
Correlation of transcutaneous and serum bilirubin levels in late preterm and term neonates at a tertiary care center in south India
Background Neonatal jaundice is one of the most prevalent condition during first week of life causing morbidity and even mortality in few, especially in low – middle income countri...
Correlation of transcutaneous and serum bilirubin levels in late preterm and term neonates at a tertiary care center in south India
Correlation of transcutaneous and serum bilirubin levels in late preterm and term neonates at a tertiary care center in south India
Background Neonatal jaundice is one of the most prevalent condition during first week of life causing morbidity and even mortality in few, especially in low – middle income countri...
Serum Copper and Plasma Protein Status in Preterm Delivery
Serum Copper and Plasma Protein Status in Preterm Delivery
Background: Preterm delivery is a major obstetric related problem in Bangladesh. Micronutrient deficiency especially deficiency of copper may affect pregnancy, delivery and outcome...
CORRELATION BETWEEN TOTAL SERUM BILIRUBIN LEVELS AND TRANSCUTANEOUS BILIRUBINOMETER VALUES IN NEONATAL JAUNDICE
CORRELATION BETWEEN TOTAL SERUM BILIRUBIN LEVELS AND TRANSCUTANEOUS BILIRUBINOMETER VALUES IN NEONATAL JAUNDICE
Background: Jaundice in newborns is a prevalent postnatal complication, typically benign in nature. To assess neonatal jaundice, the development of non-invasive techniques, such as...
Diagnostic Accuracy of Transcutaneous Bilirubinometry Versus Serum Bilirubin Level
Diagnostic Accuracy of Transcutaneous Bilirubinometry Versus Serum Bilirubin Level
Objective: To assess the diagnostic accuracy of transcutaneous bilirubinometry over serum bilirubin level in newborns with hyperbilirubinemia. Methodology: This cross-sectional stu...

Back to Top