The relative safety of an oxygenator

View through CrossRef
Analysis of prospectively registered incidents related to cardiopulmonary bypass (CPB) was initiated to establish the incident rate for 10 different oxygenator brands employed over a seven-year period in 5000 clinical perfusions. A general safety index (SI) was defined as the number of recorded incidents in a given series of oxygenators divided by its total number and multiplied by 100. Specific SI was calculated for each of the following categories: high-pressure drop, debris, gas exchange, leakage, material failure and oxygenator change-out. An SI of 0.2 was arbitrarily set as a reference and an acceptable safety level. An estimate of the relative risk for a particular oxygenator brand was compared with the reference by calculating the odd’s ratio with a 95% confidence interval. The mean SI was determined to be 1.6, ranging from 0 for the Maxima CBAS and the Cobe CML to 2.92 for the Safe oxygenator. The dominating specific type of incident was HPD with an SI of 0.81 followed by debris, SI = 0.71. A systematic analysis of adverse events in CPB may be used to evaluate and to set standards, a method already employed in the pharmaceutical industry. Our results indicate that oxygenator safety margins may vary between different brands.
Title: The relative safety of an oxygenator
Description:
Analysis of prospectively registered incidents related to cardiopulmonary bypass (CPB) was initiated to establish the incident rate for 10 different oxygenator brands employed over a seven-year period in 5000 clinical perfusions.
A general safety index (SI) was defined as the number of recorded incidents in a given series of oxygenators divided by its total number and multiplied by 100.
Specific SI was calculated for each of the following categories: high-pressure drop, debris, gas exchange, leakage, material failure and oxygenator change-out.
An SI of 0.
2 was arbitrarily set as a reference and an acceptable safety level.
An estimate of the relative risk for a particular oxygenator brand was compared with the reference by calculating the odd’s ratio with a 95% confidence interval.
The mean SI was determined to be 1.
6, ranging from 0 for the Maxima CBAS and the Cobe CML to 2.
92 for the Safe oxygenator.
The dominating specific type of incident was HPD with an SI of 0.
81 followed by debris, SI = 0.
71.
A systematic analysis of adverse events in CPB may be used to evaluate and to set standards, a method already employed in the pharmaceutical industry.
Our results indicate that oxygenator safety margins may vary between different brands.

Related Results

The Burden of Road Traffic Injuries: A Global Perspective
The Burden of Road Traffic Injuries: A Global Perspective
Introduction     Road Traffic Injury (RTI) pose a significant health challenge. It represents the eighth leading cause of death globally, prompting the UN to designate 2011-2020 as...
Air handling characteristics of five membrane oxygenators
Air handling characteristics of five membrane oxygenators
This project looked at the potential of five different membrane oxygenators to allow passage of catastrophic quantities of air in a clinically simulated environment. All the oxygen...
Can the Oxygenator Screen Filter Reduce Gaseous Microemboli?
Can the Oxygenator Screen Filter Reduce Gaseous Microemboli?
Gaseous microemboli (GME) define small bubbles as <200 μm in size. GME are reported to increase morbidity after cardiopulmonary bypass (CPB) and cardiac surgery. To prevent intr...
IoT‐based mock oxygenator for extracorporeal membrane oxygenation simulator
IoT‐based mock oxygenator for extracorporeal membrane oxygenation simulator
Abstract Background Training is an essential aspect of providing high‐quality treatment and ensuring patient safety in an...
ECMO circuit monitoring
ECMO circuit monitoring
Extracorporeal membrane oxygenation or ECMO in short, is an external circuit that acts as a heart-lung machine or life support system. This treatment is administered to critically ...
Evaluating Effects of Culture and Language on Safety
Evaluating Effects of Culture and Language on Safety
This paper (SPE 54448) was revised for publication from paper SPE 48891, prepared for the 1998 SPE International Conference and Exhibition held in Beijing, 2–6 November. Original m...
Factors Influencing Patient Safety Management Behaviors in Nursing Students
Factors Influencing Patient Safety Management Behaviors in Nursing Students
The objective of this study is to identify the critical thinking Disposition, problem-solving processes, safety motivation, patient safety management knowledge, attitudes towards p...