Experimental Investigation of Heat Transfer Augmentation in a Fin Tube Heat Exchanger Using Rectangular Winglet

View through CrossRef
Rectangular winglet is to be used to enhance Performance Evaluation Criteria of a Heat Exchanger. Heat Transfer enhancement augmentation process is to be done by several methods but one of the best method is by using a winglet. The experiment is to be done on the Wind Tunnel Test Rig. Based on this experiment, readings are to be taken with and without Rectangular winglet. After both the readings of with and without Rectangular winglet a comparison between the usage of Rectangular winglet and without the usage of Rectangular winglet is to be done on the basis of factors of Heat transfer i.e Colburn Factor, Performance Evaluation Criteria and Friction Factor. Performance Evaluation Criteria for both with and without Rectangular winglet is to be find out and is to be compared to find out the maximum Performance Evaluation Criteria. During the experimental research the Performance Evaluation Criteria with Rectangular winglet is maximum at Air Velocity 6 i.e 9.466069 and the Performance Evaluation Criteria without Rectangular winglet is maximum at Air Velocity 6 i.e 4.806861
Title: Experimental Investigation of Heat Transfer Augmentation in a Fin Tube Heat Exchanger Using Rectangular Winglet
Description:
Rectangular winglet is to be used to enhance Performance Evaluation Criteria of a Heat Exchanger.
Heat Transfer enhancement augmentation process is to be done by several methods but one of the best method is by using a winglet.
The experiment is to be done on the Wind Tunnel Test Rig.
Based on this experiment, readings are to be taken with and without Rectangular winglet.
After both the readings of with and without Rectangular winglet a comparison between the usage of Rectangular winglet and without the usage of Rectangular winglet is to be done on the basis of factors of Heat transfer i.
e Colburn Factor, Performance Evaluation Criteria and Friction Factor.
Performance Evaluation Criteria for both with and without Rectangular winglet is to be find out and is to be compared to find out the maximum Performance Evaluation Criteria.
During the experimental research the Performance Evaluation Criteria with Rectangular winglet is maximum at Air Velocity 6 i.
e 9.
466069 and the Performance Evaluation Criteria without Rectangular winglet is maximum at Air Velocity 6 i.
e 4.
806861.

Related Results

Blunt Chest Trauma and Chylothorax: A Systematic Review
Blunt Chest Trauma and Chylothorax: A Systematic Review
Abstract Introduction: Although traumatic chylothorax is predominantly associated with penetrating injuries, instances following blunt trauma, as a rare and challenging condition, ...
ANALISIS EFEKTIVITAS LIQUID SECTION HEAT EXCHANGER DENGAN TUBE IN TUBE HEAT EXCHANGER DARI SISI APLIKATIF
ANALISIS EFEKTIVITAS LIQUID SECTION HEAT EXCHANGER DENGAN TUBE IN TUBE HEAT EXCHANGER DARI SISI APLIKATIF
Penelitian ini menjelaskan tentang aplikasidari LSHX yang lebih baik daripada jenis heat exchanger lainnyaagar penggunaan penukar kalor tipe ini lebih efektif dan dapat diaplikasik...
Design of Cross Flow Heat Exchanger Using Performance Charts
Design of Cross Flow Heat Exchanger Using Performance Charts
The manuscript reviews the various steps involved in the design of a cross flow heat exchanger. Performance charts describing the thermal performance of the heat exchanger in terms...
Effect of Vortex Generator Angle on Fin and Tube Heat Exchanger
Effect of Vortex Generator Angle on Fin and Tube Heat Exchanger
In refrigeration systems, a common installed component is the fin and tube heat exchanger. The fluid that passes through the fins has lower thermal conductivity than the fluid flow...
Improvement of Plate-Fin Heat Exchanger Performance with Assistance of Various Types of Vortex Generator
Improvement of Plate-Fin Heat Exchanger Performance with Assistance of Various Types of Vortex Generator
A 3-dimensional incompressible laminar flow and heat-transfer in a plate-fin heat exchanger (PFHE) where investigated numerically in this article. The influence of mounting a longi...
Fluid and Structure Analysis of Wind Turbine Blade with Winglet
Fluid and Structure Analysis of Wind Turbine Blade with Winglet
One of the succeeded methods to enhance the performance of horizontal axis wind turbine (HAWT) is an attaching a winglet to the blades tip. The current paper study the effect of fo...
Heat Exchanger Design and Optimization
Heat Exchanger Design and Optimization
Heat exchangers are devices that transfer heat energy between fluids by utilizing heat transfer modes of conduction and convection. The shell and tube heat exchanger configuration ...