Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Effect of a New Vortex Generator on the Performance of an Axial Compressor Cascade at Design and Off-Design Conditions

View through CrossRef
Secondary flows are noxious to axial compressor performance. To overcome and control those secondary flows, vortex generators are used as a passive control device. Controlling secondary flows will lead to a further improvements in the compressor performance. A new design of vortex generator is considered in this investigation in order to control secondary flows in axial compressor cascade at design and off-design conditions. Numerical simulations of a three-dimensional compressible turbulent flow have been performed to explore the effect of the vortex generators on the reduction of secondary flows. Six different incidence angles are used for the off-design operation investigations. Based on the simulation results, the pressure, velocity, and streamline are used to follow up the development of the secondary flows. Thence, total pressure loss coefficient, static pressure rise coefficient, difference in flow deflection angle, and diffusion factor are estimated. Results indicate that vortex generators have a significant effect on the development of secondary flows at off design operation as they cause a reduction in total pressure loss, they also affect the loading behavior of the cascade as they cause a slight change in the cascade deflection, and a slight decrease in the diffusion factor which causes unloading of the blade. Static pressure rise is significantly reduced at negative incidence angles while a slight reduction occurs at positive incidence angles. In a word, the new design of the vortex generator enhances the cascade aerodynamic performance and enlarges the operating range of the cascade towards the positive incidence region.
Title: Effect of a New Vortex Generator on the Performance of an Axial Compressor Cascade at Design and Off-Design Conditions
Description:
Secondary flows are noxious to axial compressor performance.
To overcome and control those secondary flows, vortex generators are used as a passive control device.
Controlling secondary flows will lead to a further improvements in the compressor performance.
A new design of vortex generator is considered in this investigation in order to control secondary flows in axial compressor cascade at design and off-design conditions.
Numerical simulations of a three-dimensional compressible turbulent flow have been performed to explore the effect of the vortex generators on the reduction of secondary flows.
Six different incidence angles are used for the off-design operation investigations.
Based on the simulation results, the pressure, velocity, and streamline are used to follow up the development of the secondary flows.
Thence, total pressure loss coefficient, static pressure rise coefficient, difference in flow deflection angle, and diffusion factor are estimated.
Results indicate that vortex generators have a significant effect on the development of secondary flows at off design operation as they cause a reduction in total pressure loss, they also affect the loading behavior of the cascade as they cause a slight change in the cascade deflection, and a slight decrease in the diffusion factor which causes unloading of the blade.
Static pressure rise is significantly reduced at negative incidence angles while a slight reduction occurs at positive incidence angles.
In a word, the new design of the vortex generator enhances the cascade aerodynamic performance and enlarges the operating range of the cascade towards the positive incidence region.

Related Results

Stability and dynamics of geophysical neutral vortices
Stability and dynamics of geophysical neutral vortices
(English) Mesoscale and submesoscale vortical structures are ubiquitous in the ocean and atmosphere. Most of these vortices are long-lived with a lifetime of several months. They o...
Effects of Vortex-Vortex Interaction in a Compressor Cascade With Vortex Generators
Effects of Vortex-Vortex Interaction in a Compressor Cascade With Vortex Generators
This paper presents a numerical investigation to explore the effects of vortex generators on a high speed compressor cascade. Secondary flow effects like the corner separation vort...
Investigation of vortex in pump sump by V3V measurements
Investigation of vortex in pump sump by V3V measurements
Abstract The aims, scope and conclusions of the paper must be in a self-contained abstract of a single paragraph with 60-120 words. The abstract must be informative ...
Effect of Airfoil Vortex Generator on the Performance and Stability of a Transonic Axial Compressor
Effect of Airfoil Vortex Generator on the Performance and Stability of a Transonic Axial Compressor
Abstract In the present research work, effect of airfoil vortex generator on performance and stability of transonic compressor stage is investigated through CFD simu...
Eyes of Aniso-Axial Length Individuals Share Generally Similar Corneal Biometrics with Normal Eyes in Cataract Population
Eyes of Aniso-Axial Length Individuals Share Generally Similar Corneal Biometrics with Normal Eyes in Cataract Population
Aims. To determine the characteristics of corneal biometrics in eyes from aniso-axial length cataract patients compared with eyes from non-aniso-axial length individuals. Methods. ...
The Effects of Wet Compression on Gas Turbine Engine Operating Performance
The Effects of Wet Compression on Gas Turbine Engine Operating Performance
Water, in the liquid or vapor phase, injected at various locations into the gas turbine cycle has frequently been employed to improve engine performance. One such way to improve en...
Root Cause Analysis of the Catastrophic Failure of a Propylene Recycle Compressor
Root Cause Analysis of the Catastrophic Failure of a Propylene Recycle Compressor
Abstract A 2-section, 6-stage propylene recycle compressor experienced a catastrophic failure that resulted in extensive damage to its internals. The compressor was ...

Back to Top