Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

The Evaluation of a Novel Three-Dimensional Printed Expandable Pedicle Screw Sleeve Insert

View through CrossRef
When used in combination with decompression, spinal fusion is a successful procedure for treating patients with spinal stenosis and degenerative spondylolisthesis. While a number of auxiliary devices have been proposed to enhance the fixation of the screw within the pedicle and vertebral body, there is conflicting information regarding the efficacy of their use. Therefore, the aim of this study was to determine the ability of a novel expandable pedicle screw to improve the fixation of the pedicle screw within the pedicle and vertebral body. A three-dimensional (3D) printed, screw sleeve was designed that expanded within the pedicle and vertebral body when a standard pedicle screw was inserted into it. The left and right pedicle of ten (N = 10) cadaveric lumbar spine specimens (L3–L5) were randomly assigned to be instrumented with either a pedicle screw and the sleeve or a pedicle screw only. Following instrumentation, the screws were exposed to tensile load at 5 mm/min until failure. The failure force, failure deformation, and area under the force–deformation curve were determined and compared between screw conditions. There were no significant differences between the screws and sleeve, and the screw only conditions for the failure force (p = 0.24), failure displacement (p = 0.10), and area under the curve (p = 0.38). While the novel screw sleeve presented here performed as well as a screw without a sleeve, it was better than other screw augmentation devices reported previously. In addition, it is likely that this device would prove useful as an enhancement to revision.
Title: The Evaluation of a Novel Three-Dimensional Printed Expandable Pedicle Screw Sleeve Insert
Description:
When used in combination with decompression, spinal fusion is a successful procedure for treating patients with spinal stenosis and degenerative spondylolisthesis.
While a number of auxiliary devices have been proposed to enhance the fixation of the screw within the pedicle and vertebral body, there is conflicting information regarding the efficacy of their use.
Therefore, the aim of this study was to determine the ability of a novel expandable pedicle screw to improve the fixation of the pedicle screw within the pedicle and vertebral body.
A three-dimensional (3D) printed, screw sleeve was designed that expanded within the pedicle and vertebral body when a standard pedicle screw was inserted into it.
The left and right pedicle of ten (N = 10) cadaveric lumbar spine specimens (L3–L5) were randomly assigned to be instrumented with either a pedicle screw and the sleeve or a pedicle screw only.
Following instrumentation, the screws were exposed to tensile load at 5 mm/min until failure.
The failure force, failure deformation, and area under the force–deformation curve were determined and compared between screw conditions.
There were no significant differences between the screws and sleeve, and the screw only conditions for the failure force (p = 0.
24), failure displacement (p = 0.
10), and area under the curve (p = 0.
38).
While the novel screw sleeve presented here performed as well as a screw without a sleeve, it was better than other screw augmentation devices reported previously.
In addition, it is likely that this device would prove useful as an enhancement to revision.

Related Results

Stiffness Comparisons of SOP Interlocking Plate Configurations in 3D Printed Canine Lumbosacral Vertebrae
Stiffness Comparisons of SOP Interlocking Plate Configurations in 3D Printed Canine Lumbosacral Vertebrae
There are no published biomechanical studies evaluating the effect of stabilization techniques on the stability of the 3D printed models of the canine lumbosacral junction. The p...
Determination of effective riser sleeve thermophysical properties for simulation and analysis of riser sleeve performance
Determination of effective riser sleeve thermophysical properties for simulation and analysis of riser sleeve performance
<p>Riser sleeve thermophysical properties for simulation are developed using an inverse modeling technique. Casting experiments using riser sleeves are performed in order to ...
Minimizing Pedicle Screw Pullout Risks
Minimizing Pedicle Screw Pullout Risks
Study Design: Detailed biomechanical analysis of the anchorage performance provided by different pedicle screw designs and placement strategies under pullout loading. ...
Biomechanical characterization of bilateral pedicle screw internal fixation combinations on lumbar vertebrae
Biomechanical characterization of bilateral pedicle screw internal fixation combinations on lumbar vertebrae
Purpose Pedicle screw fixation has been considered a suitable surgical intervention for addressing a diverse range of indications involving the lumbar spinal segments, but the...
Biomechanical analysis of pedicle screw placement: a feasibility study
Biomechanical analysis of pedicle screw placement: a feasibility study
In spinal instrumentation surgery, the optimal placement of pedicle screws that takes into account the cortical/cancellous bone quality, geometry and property distribution, and scr...

Back to Top