Javascript must be enabled to continue!
The Effect of Cannulated Screw Placement Angle in the Management of Femoral Neck Fracture
View through CrossRef
Fixation with cannulated screw was widely accepted for management of femoral neck fracture. However, the angle of placement cannulated screw for management of femoral neck fracture still controversial. The present study aims to investigate the mechanical behavior of the cannulated screws with two different angles of placements which are 135o and 150o in inverted triangular configuration for management of femoral neck fracture via finite element method. Therefore, the 3D model of a proximal femur consist of femoral neck fracture was constructed from CT data images using medical image processing software. The von Mises stress distributions on the cannulated screws were compared between each screw angle placement. The result showed that the cannulated screws in inverted triangle with 135o of placement angle have better stress distributions than 150o placement angle.
Trans Tech Publications, Ltd.
Title: The Effect of Cannulated Screw Placement Angle in the Management of Femoral Neck Fracture
Description:
Fixation with cannulated screw was widely accepted for management of femoral neck fracture.
However, the angle of placement cannulated screw for management of femoral neck fracture still controversial.
The present study aims to investigate the mechanical behavior of the cannulated screws with two different angles of placements which are 135o and 150o in inverted triangular configuration for management of femoral neck fracture via finite element method.
Therefore, the 3D model of a proximal femur consist of femoral neck fracture was constructed from CT data images using medical image processing software.
The von Mises stress distributions on the cannulated screws were compared between each screw angle placement.
The result showed that the cannulated screws in inverted triangle with 135o of placement angle have better stress distributions than 150o placement angle.
Related Results
Femoral Neck Fractures
Femoral Neck Fractures
(1) Repair of displaced femoral neck fractures has a high risk of treatment failure compared with most other fractures. These failures often require salvage surgery, including oste...
Blunt Chest Trauma and Chylothorax: A Systematic Review
Blunt Chest Trauma and Chylothorax: A Systematic Review
Abstract
Introduction: Although traumatic chylothorax is predominantly associated with penetrating injuries, instances following blunt trauma, as a rare and challenging condition, ...
Stochastic Propagation of Discrete Fracture Networks
Stochastic Propagation of Discrete Fracture Networks
This reference is for an abstract only. A full paper was not submitted for this conference.
Abstract
Fractures are ubiquitous st...
A comparative study of early functional outcomes in undisplaced neck of femur fracture treated with partially threaded and fully threaded cannulated screw fixation in patients above 60 years age
A comparative study of early functional outcomes in undisplaced neck of femur fracture treated with partially threaded and fully threaded cannulated screw fixation in patients above 60 years age
Objective: To compare the partially threaded versus fully threaded cannulated screw fixation methods in stable neck of femur fracture in terms of early functional outcomes in patie...
Enhanced Stability in an Unstable Femoral Neck Fracture Using the Femoral Neck System with Two Additional Cannulated Cancellous Screws: A Case Report
Enhanced Stability in an Unstable Femoral Neck Fracture Using the Femoral Neck System with Two Additional Cannulated Cancellous Screws: A Case Report
Introduction: Femoral neck fractures in young adults require urgent anatomical reduction and stable fixation to preserve the native femoral head and prevent complications, such as ...
Calcar buttressed screw fixation for femoral neck fracture
Calcar buttressed screw fixation for femoral neck fracture
<p class="abstract"><strong>Background:</strong> The incidence of neck of femur fracture among elderly population is increasing day by day. Femoral neck fracture ...
Titanium alloy cannulated screws and biodegradable magnesium alloy bionic cannulated screws for treatment of femoral neck fractures: a finite element analysis
Titanium alloy cannulated screws and biodegradable magnesium alloy bionic cannulated screws for treatment of femoral neck fractures: a finite element analysis
Abstract
Background
Cannulated screws (CS) are one of the most widely used treatments for femoral neck fracture, however, associated with high rate ...
Cannulated Compression Screw Placement for Swine Femoral Neck Fracture to Protect the Main Intraosseous Arteries
Cannulated Compression Screw Placement for Swine Femoral Neck Fracture to Protect the Main Intraosseous Arteries
ABSTRACTFemoral head necrosis is a common and serious complication of femoral neck fractures, primarily attributed to disrupted blood supply. This study introduces a novel method o...