Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

The CRILIN calorimeter: gamma radiation resistance of crystals and SiPMs

View through CrossRef
Abstract The Crilin calorimeter is a semi-homogeneous calorimetric system based on Lead Fluoride (PbF2) crystals with UV-extended Silicon Photomultipliers (SiPMs) proposed for the Muon Collider. This study investigates the radiation resistance of crystals and SiPMs, subjected to 10 kGy gamma irradiation, equivalent to a 10-year service life in the Muon Collider. Our findings indicate that while PbF2 crystals exhibit a decrease in transmittance post-irradiation with partial recovery over time, the alternative PbWO4-Ultra Fast (PWO-UF) demonstrates exceptional radiation hardness, maintaining stable transmittance. SiPMs showed an increase in dark current and breakdown voltage post-irradiation, with less degradation observed in the SiPM biased during the exposure to radiation compared to the unbiased component. These results underscore the viability of PbF2 for radiation-tolerant calorimeters, though improvements in production homogeneity are needed. The superior performance of PWO-UF crystals suggests they are a promising alternative for high-radiation applications, but their higher cost must be carefully considered.
Title: The CRILIN calorimeter: gamma radiation resistance of crystals and SiPMs
Description:
Abstract The Crilin calorimeter is a semi-homogeneous calorimetric system based on Lead Fluoride (PbF2) crystals with UV-extended Silicon Photomultipliers (SiPMs) proposed for the Muon Collider.
This study investigates the radiation resistance of crystals and SiPMs, subjected to 10 kGy gamma irradiation, equivalent to a 10-year service life in the Muon Collider.
Our findings indicate that while PbF2 crystals exhibit a decrease in transmittance post-irradiation with partial recovery over time, the alternative PbWO4-Ultra Fast (PWO-UF) demonstrates exceptional radiation hardness, maintaining stable transmittance.
SiPMs showed an increase in dark current and breakdown voltage post-irradiation, with less degradation observed in the SiPM biased during the exposure to radiation compared to the unbiased component.
These results underscore the viability of PbF2 for radiation-tolerant calorimeters, though improvements in production homogeneity are needed.
The superior performance of PWO-UF crystals suggests they are a promising alternative for high-radiation applications, but their higher cost must be carefully considered.

Related Results

On Proximal Relations in Transformation Semigroups Arising from Generalized Shifts
On Proximal Relations in Transformation Semigroups Arising from Generalized Shifts
For a finite discrete topological space $X$ with at least two elements, a nonempty set $\Gamma$, and a map $\varphi:\Gamma \to \Gamma$, $\sigma_{\varphi}:X^{\Gamma} \to X^{\Gamma}$...
SIMPLE FORMS OF ZIRCON CRYSTALS FROM CRYSTALLINE ROCKS OF THE UKRAINIAN SHIELD AND THEIR MORPHOLOGICAL TYPES
SIMPLE FORMS OF ZIRCON CRYSTALS FROM CRYSTALLINE ROCKS OF THE UKRAINIAN SHIELD AND THEIR MORPHOLOGICAL TYPES
The main basics in geometric crystallography of zircon, developed by many researchers in the 18th - 20th centuries, are briefly described. The data of goniometric study of zircon f...
North Syrian Mortaria and Other Late Roman Personal and Utility Objects Bearing Inscriptions of Good Luck
North Syrian Mortaria and Other Late Roman Personal and Utility Objects Bearing Inscriptions of Good Luck
<span style="font-size: 11pt; color: black; font-family: 'Times New Roman','serif'">&Pi;&Eta;&Lambda;&Iota;&Nu;&Alpha; &Iota;&Gamma;&Delta...
Energy resolution values of GAGG:Ce crystals coupled to various SiPMs
Energy resolution values of GAGG:Ce crystals coupled to various SiPMs
Abstract GAGG:Ce (Gadolinium Aluminum Gallium Garnet doped with Cerium) crystals coupled with SiPMs (Silicon Photomultipliers) form a scintil...
Crilin: A CRystal calorImeter with Longitudinal InformatioN for a future Muon Collider
Crilin: A CRystal calorImeter with Longitudinal InformatioN for a future Muon Collider
Abstract The measurement of physics processes at new energy frontier experiments requires excellent spatial, time, and energy resolutions to resolve the structur...
Crilin: CRystal calorImeter with Longitudinal InformatioN for a future Muon Collider
Crilin: CRystal calorImeter with Longitudinal InformatioN for a future Muon Collider
In modern experiment, a high granularity is required in order to distinguish signal particles from background and to solve the substructures necessary for jet identification. Time ...
Ice Growth and Platelet Crystals in Antarctica
Ice Growth and Platelet Crystals in Antarctica
<p>First-year land-fast sea ice growth in both the Arctic and the Antarctic is characterised by the formation of an initial ice cover, followed by the direct freezing of seaw...
Advancements in Muon Collider Calorimetry: Design, Testing, and Radiation Resistance of the Crilin Calorimeter Prototype
Advancements in Muon Collider Calorimetry: Design, Testing, and Radiation Resistance of the Crilin Calorimeter Prototype
The Crilin calorimeter is a semi-homogeneous calorimetric system that uses Lead Fluoride (PbF2) crystals with UV-extended Silicon Photomultipliers (SiPMs). Proposed for the Muon Co...

Back to Top