Javascript must be enabled to continue!
Crilin: A CRystal calorImeter with Longitudinal InformatioN for a future Muon Collider
View through CrossRef
Abstract
The measurement of physics processes at new energy frontier
experiments requires excellent spatial, time, and energy resolutions
to resolve the structure of collimated high-energy jets. In a future
Muon Collider, the beam-induced backgrounds (BIB) represent the main
challenge in the design of the detectors and of the event
reconstruction algorithms. The technology and the design of the
calorimeters should be chosen to reduce the effect of the BIB, while
keeping good physics performance. Several requirements can be
inferred: i) high granularity to reduce the overlap of BIB particles
in the same calorimeter cell; ii) excellent timing (of the order of
100 ps) to reduce the out-of-time component of the BIB; iii)
longitudinal segmentation to distinguish the signal showers from the
fake showers produced by the BIB; iv) good energy resolution (less
than 10%/√E) to obtain good physics performance, as has
been already demonstrated for conceptual particle flow calorimeters.
Our proposal consists of a semi-homogeneous electromagnetic
calorimeter based on lead fluoride crystals (PbF2) read out by
surface-mount UV-extended Silicon Photomultipliers (SiPMs): the
Crilin calorimeter. In this paper, the performance of the Crilin
calorimeter in the Muon Collider framework for hadron jets
reconstruction has been analyzed. We report the characterisation of
individual components together with the development of a small-scale
prototype, consisting of 2 layers of 3 × 3 crystals each.
Title: Crilin: A CRystal calorImeter with Longitudinal InformatioN for a future Muon Collider
Description:
Abstract
The measurement of physics processes at new energy frontier
experiments requires excellent spatial, time, and energy resolutions
to resolve the structure of collimated high-energy jets.
In a future
Muon Collider, the beam-induced backgrounds (BIB) represent the main
challenge in the design of the detectors and of the event
reconstruction algorithms.
The technology and the design of the
calorimeters should be chosen to reduce the effect of the BIB, while
keeping good physics performance.
Several requirements can be
inferred: i) high granularity to reduce the overlap of BIB particles
in the same calorimeter cell; ii) excellent timing (of the order of
100 ps) to reduce the out-of-time component of the BIB; iii)
longitudinal segmentation to distinguish the signal showers from the
fake showers produced by the BIB; iv) good energy resolution (less
than 10%/√E) to obtain good physics performance, as has
been already demonstrated for conceptual particle flow calorimeters.
Our proposal consists of a semi-homogeneous electromagnetic
calorimeter based on lead fluoride crystals (PbF2) read out by
surface-mount UV-extended Silicon Photomultipliers (SiPMs): the
Crilin calorimeter.
In this paper, the performance of the Crilin
calorimeter in the Muon Collider framework for hadron jets
reconstruction has been analyzed.
We report the characterisation of
individual components together with the development of a small-scale
prototype, consisting of 2 layers of 3 × 3 crystals each.
Related Results
R&D status for an innovative crystal calorimeter for the future Muon Collider
R&D status for an innovative crystal calorimeter for the future Muon Collider
The measurement of physics processes at new energy frontier experiments requires excellent spatial, time, and energy resolutions to resolve the structure of collimated high-energy ...
Crilin: CRystal calorImeter with Longitudinal InformatioN for a future Muon Collider
Crilin: CRystal calorImeter with Longitudinal InformatioN for a future Muon Collider
In modern experiment, a high granularity is required in order to distinguish signal particles from background and to solve the substructures necessary for jet identification. Time ...
Design and beam-test characterization of the CRILIN semi-homogeneous crystal calorimeter
Design and beam-test characterization of the CRILIN semi-homogeneous crystal calorimeter
Abstract
CRILIN is a high-granularity semi-homogeneous
electromagnetic calorimeter based on longitudinally segmented
PbF
...
Crilin: A Semi-Homogeneous Calorimeter for a Future Muon Collider
Crilin: A Semi-Homogeneous Calorimeter for a Future Muon Collider
Calorimeters, as other detectors, have to face the increasing performance demands of the new energy frontier experiments. For a future Muon Collider the main challenge is given by ...
Fermion-portal dark matter at a high-energy muon collider
Fermion-portal dark matter at a high-energy muon collider
In this work, we provide a comprehensive study of fermion-portal dark matter models in the freeze-in regime at a future muon collider. For different possible nonsinglet fermion por...
Advancements in Muon Collider Calorimetry: Design, Testing, and Radiation Resistance of the Crilin Calorimeter Prototype
Advancements in Muon Collider Calorimetry: Design, Testing, and Radiation Resistance of the Crilin Calorimeter Prototype
The Crilin calorimeter is a semi-homogeneous calorimetric system that uses Lead Fluoride (PbF2) crystals with UV-extended Silicon Photomultipliers (SiPMs). Proposed for the Muon Co...
IDENTIFIKASI MATERIAL DENGAN TOMOGRAFI MUON KOSMIK MENGGUNAKAN DETEKTOR BERBASIS CMOS MEMANFAATKAN WEBCAM
IDENTIFIKASI MATERIAL DENGAN TOMOGRAFI MUON KOSMIK MENGGUNAKAN DETEKTOR BERBASIS CMOS MEMANFAATKAN WEBCAM
Partikel muon (μ) adalah partikel elementer yang dihasilkan oleh sinar kosmik ketika menembus ke permukaan bumi dan dapat kita temui dalam kehidupan sehari-hari. Muon memiliki muat...
Mechanical Design of an Electromagnetic Calorimeter Prototype for a Future Muon Collider
Mechanical Design of an Electromagnetic Calorimeter Prototype for a Future Muon Collider
Measurement of physics processes at new energy frontier experiments requires excellent spatial, time, and energy resolutions to resolve the structure of collimated high-energy jets...

