Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

EVALUATION OF OCCUPATIONAL RADIATION EXPOSURE IN A RADIO-DIAGNOSTIC FACILITY IN KATSINA- NIGERIA

View through CrossRef
Poor implementation of quality assurance programs in the radiation industry has been a major setback in our locality. Several studies revealed that occupational workers are exposed to many potential hazards of ionizing radiation during radio-diagnostic procedures, yet radiation workers are often not monitored. This study aims to evaluate the occupational exposure of the radiation workers in Federal Medical Centre Katsina, and to compare the exposure with recommended occupational radiation dose limits. The quarterly readings of 20 thermo-luminescent dosimeters (TLDs') used by the radiation workers from January to December, 2019 were collected from the facility's radiation monitoring archive, and subsequently assessed and analyzed. The results indicate that the average annual equivalent dose per occupational worker range from 0.74 to 1.20 mSv and 1.28 to 2.21 mSv for skin surface and deep skin dose, measured at 10 mm and 0.07 mm tissue depth respectively. The occupational dose was within the recommended national and international limits of 5 mSv per annum or an average of 20 mSv in 5 years. Therefore, there was no significant radiation exposure to all the occupational workers in the study area. Though, the occupational radiation dose is within recommended limit, this does not eliminate stochastic effect of radiation. The study recommended that the occupational workers should adhere and strictly comply with the principles of radiation protection which includes distance, short exposure time, shielding and proper monitoring of dose limits. Furthermore, continuous training of the radiation workers is advised.
Title: EVALUATION OF OCCUPATIONAL RADIATION EXPOSURE IN A RADIO-DIAGNOSTIC FACILITY IN KATSINA- NIGERIA
Description:
Poor implementation of quality assurance programs in the radiation industry has been a major setback in our locality.
Several studies revealed that occupational workers are exposed to many potential hazards of ionizing radiation during radio-diagnostic procedures, yet radiation workers are often not monitored.
This study aims to evaluate the occupational exposure of the radiation workers in Federal Medical Centre Katsina, and to compare the exposure with recommended occupational radiation dose limits.
The quarterly readings of 20 thermo-luminescent dosimeters (TLDs') used by the radiation workers from January to December, 2019 were collected from the facility's radiation monitoring archive, and subsequently assessed and analyzed.
The results indicate that the average annual equivalent dose per occupational worker range from 0.
74 to 1.
20 mSv and 1.
28 to 2.
21 mSv for skin surface and deep skin dose, measured at 10 mm and 0.
07 mm tissue depth respectively.
The occupational dose was within the recommended national and international limits of 5 mSv per annum or an average of 20 mSv in 5 years.
Therefore, there was no significant radiation exposure to all the occupational workers in the study area.
Though, the occupational radiation dose is within recommended limit, this does not eliminate stochastic effect of radiation.
The study recommended that the occupational workers should adhere and strictly comply with the principles of radiation protection which includes distance, short exposure time, shielding and proper monitoring of dose limits.
Furthermore, continuous training of the radiation workers is advised.

Related Results

Migrasi Radio Konvensional menjadi Radio Digital
Migrasi Radio Konvensional menjadi Radio Digital
Abstract. The digitalization process in the radio broadcasting industry has made radio easy to access and consume by loyal radio listeners. Digital radio is a new trend among broad...
Magnetohydrodynamics enhanced radio blackout mitigation system for spacecraft during planetary entries
Magnetohydrodynamics enhanced radio blackout mitigation system for spacecraft during planetary entries
(English) Spacecraft entering planetary atmospheres are enveloped by a plasma layer with high levels of ionization, caused by the extreme temperatures in the shock layer. The charg...
Pengelolaan Platform Digital Penyiaran pada Urban Radio 106.3 FM
Pengelolaan Platform Digital Penyiaran pada Urban Radio 106.3 FM
Abstract. Urban Radio 106.3 FM is one of the modern radio stations broadcasting on the frequency 106.3 FM in the city of Bandung. This research is focused on the "Management of Dig...
Suffering of Patients with Neurogenic Thoracic Outlet Syndrome (TOS); The First Qualitative study in TOS
Suffering of Patients with Neurogenic Thoracic Outlet Syndrome (TOS); The First Qualitative study in TOS
Abstract Background Diagnosis of neurogenic thoracic outlet syndrome (nTOS) is hindered by symptom overlap with cervical radiculopathy, carpal tunnel syndrome, or psychosomatic dis...
PROBLEMS OF RADIATION PROTECTION OF RADIOLOGISTS IN PRIMARY HEALTH CARE
PROBLEMS OF RADIATION PROTECTION OF RADIOLOGISTS IN PRIMARY HEALTH CARE
Background. Radiologists play a crucial role in modern healthcare by ensuring timely diagnosis of a wide range of diseases. Despite significant advances in diagnostic imaging techn...
Radio Emission of Nearby Early-type Galaxies in the Low and Very Low Radio Luminosity Range
Radio Emission of Nearby Early-type Galaxies in the Low and Very Low Radio Luminosity Range
Abstract We analyze radio continuum emission of early-type galaxies with dynamical measurements of central supermassive black hole (SMBH) masses and well-characteriz...

Back to Top