Javascript must be enabled to continue!
A new way of measuring the contribution of scattered photons to x‐ray fluorescence yields in secondary excitation mode
View through CrossRef
Abstract
The characteristic K x‐rays from a secondary exciter in conjunction with an x‐ray tube or a radioisotope as primary source are frequently used for target excitation in x‐ray fluorescence measurements. In this experimental arrangement, the exciting photon spectrum consists of two parts: (i) characteristic K x‐rays of the secondary exciter and (ii) photons from the primary source, which are scattered from the secondary exciter. A new method is proposed for correcting the observed target x‐ray yield due to unwanted excitation by the scattered photons. This method involves measurement of x‐ray yield after replacing the secondary exciter by an equivalent exciter consisting of a low‐
Z
element foil with a high‐
Z
element backing. Copyright © 2004 John Wiley & Sons, Ltd.
Title: A new way of measuring the contribution of scattered photons to x‐ray fluorescence yields in secondary excitation mode
Description:
Abstract
The characteristic K x‐rays from a secondary exciter in conjunction with an x‐ray tube or a radioisotope as primary source are frequently used for target excitation in x‐ray fluorescence measurements.
In this experimental arrangement, the exciting photon spectrum consists of two parts: (i) characteristic K x‐rays of the secondary exciter and (ii) photons from the primary source, which are scattered from the secondary exciter.
A new method is proposed for correcting the observed target x‐ray yield due to unwanted excitation by the scattered photons.
This method involves measurement of x‐ray yield after replacing the secondary exciter by an equivalent exciter consisting of a low‐
Z
element foil with a high‐
Z
element backing.
Copyright © 2004 John Wiley & Sons, Ltd.
Related Results
Applications of Total Scanning Fluorescence to Exploration Geochemistry
Applications of Total Scanning Fluorescence to Exploration Geochemistry
ABSTRACT
A total scanning fluorescence technique is described for correlation (oil/oil and oil/source rock) and surface geochemical prospecting studies. The fluor...
Multi-photon quantum interference and entanglement
Multi-photon quantum interference and entanglement
Interférence et intrication quantiques à plusieurs photons
Dans cette thèse de doctorat, nous étudions des caractéristiques clés du traitement optique de l'informat...
Research on fluorescence lifetime dynamics of quantum dot by single photons modulation spectrum
Research on fluorescence lifetime dynamics of quantum dot by single photons modulation spectrum
Fluorescence lifetime is an important characteristic parameter of quantum dot, which plays an important role in studying the optical properties of quantum dot. As a common method t...
Two-photon fluorescence excitation in detection of biomolecules
Two-photon fluorescence excitation in detection of biomolecules
Two-photon fluorescence excitation has been found to be a very powerful method for enhancing the sensitivity and resolution in far-field light microscopy. Two-photon fluorescence e...
Multiphoton Fluorescence Light Microscopy
Multiphoton Fluorescence Light Microscopy
Abstract
Multiphoton fluorescence microscopy is a powerful imaging technique that depends on complex quantum mechanical interacti...
Multiphoton Fluorescence Light Microscopy
Multiphoton Fluorescence Light Microscopy
Abstract
Multiphoton fluorescence microscopy is a powerful imaging technique that depends on complex quantum mechanical interacti...
Energy‐Dispersive Spectrometry
Energy‐Dispersive Spectrometry
AbstractEnergy‐dispersive x‐ray spectrometry (EDS) is a technique for measuring the intensity of x‐ray emission as a function of the energy of the x‐ray photons. The excitation sou...
SU‐FF‐I‐53: X‐Ray Scattering and Fluorescence Spectroscopy as a Possible Tool for KVp Monitoring
SU‐FF‐I‐53: X‐Ray Scattering and Fluorescence Spectroscopy as a Possible Tool for KVp Monitoring
Small changes in the peak voltage of a diagnostic x‐ray tube can cause significant modifications in the absorbed dose or degrade the contrast of an x‐ray image. It has been suggest...

