Javascript must be enabled to continue!
Highly accurate adjustment and stabilization of a fiber interferometer for displacement measurements
View through CrossRef
An interferometer used for displacement measurement is typically adjusted to the center or another appropriate point of the interferometer fringe as a working point to yield maximum detection sensitivity and linearity. The interferometer is prone to varying misalignment in the course of measurements, most noticeable due to thermal drift affecting the interferometer dimensions. We introduce an automatic correction mechanism based on a proportional/integral (PI) control loop to remove any error in the alignment of the fiber interferometer, specifically long-term drift. The method is based on introducing a harmonic displacement by driving an optical element, which is a micro-cantilever in this work. The second harmonic of the interferometric signal that is shown to be present only for a misaligned Michelson or low-finesse Fabry–Pérot interferometer is processed using a lock-in detector, phase-locked to the drive signal, where the in-phase output signal is used as the feedback signal of the PI control loop operated with zero signal setpoint. The loop output control signal is amplified and supplied to the piezo element, adjusting the optical element to yield perfect alignment. As thermal drift is a slow process, the control loop can mostly be operated with a large time constant, allowing for a highly accurate stabilization, limiting misalignment to less than 2% of the interferometer fringe.
Title: Highly accurate adjustment and stabilization of a fiber interferometer for displacement measurements
Description:
An interferometer used for displacement measurement is typically adjusted to the center or another appropriate point of the interferometer fringe as a working point to yield maximum detection sensitivity and linearity.
The interferometer is prone to varying misalignment in the course of measurements, most noticeable due to thermal drift affecting the interferometer dimensions.
We introduce an automatic correction mechanism based on a proportional/integral (PI) control loop to remove any error in the alignment of the fiber interferometer, specifically long-term drift.
The method is based on introducing a harmonic displacement by driving an optical element, which is a micro-cantilever in this work.
The second harmonic of the interferometric signal that is shown to be present only for a misaligned Michelson or low-finesse Fabry–Pérot interferometer is processed using a lock-in detector, phase-locked to the drive signal, where the in-phase output signal is used as the feedback signal of the PI control loop operated with zero signal setpoint.
The loop output control signal is amplified and supplied to the piezo element, adjusting the optical element to yield perfect alignment.
As thermal drift is a slow process, the control loop can mostly be operated with a large time constant, allowing for a highly accurate stabilization, limiting misalignment to less than 2% of the interferometer fringe.
Related Results
Comparison of sensitivity to beam collimation of the holographic shearing interferometer with the wedge plate shearing interferometer and the Talbot shearing interferometer
Comparison of sensitivity to beam collimation of the holographic shearing interferometer with the wedge plate shearing interferometer and the Talbot shearing interferometer
High sensitivity of collimation testing equipment is desirable where collimated beams are used for precise and accurate measurements. Precision in the setting of collimation depend...
Spatial phase-shifting polarization point-piffraction interferometer for wavefront measurement
Spatial phase-shifting polarization point-piffraction interferometer for wavefront measurement
Wavefront measurement is widely used in the field of optical manufacturing, military, astronomy, medical treatment, etc., and it reflects the performance of the optical system thro...
Long Versus Short-segment Stabilization in Patients with Traumatic Thoracolumbar Fractures
Long Versus Short-segment Stabilization in Patients with Traumatic Thoracolumbar Fractures
Background. Posterior stabilization surgery is considered the gold standard for restoring spine stability in patients with traumatic thoracolumbar fractures. However, whether long-...
Interference Fringe Analysis for Precision Measurement by Using Conoscopic Interferometer
Interference Fringe Analysis for Precision Measurement by Using Conoscopic Interferometer
In this paper, we propose a novel fringe phase analysis method that can quickly and accurately perform the interference fringe analysis for precise measurement by using a conoscopi...
Mach-Zehnder interferometer based on fiber taper and fiber core mismatch for humidity sensing
Mach-Zehnder interferometer based on fiber taper and fiber core mismatch for humidity sensing
A simple and high sensitivity optical fiber relative humidity (RH) sensor based on Mach-Zehnder interferometer (MZI) is proposed and demonstrated in this paper. A single-mode fiber...
Relationship between Empathy, Forgiveness and Marital Adjustment in Couples
Relationship between Empathy, Forgiveness and Marital Adjustment in Couples
Introduction: Marital adjustment is gaining increasing concern in the modern society. Marital adjustment is a process during which partners in a marriage change and adapt to their ...
The Knob Domain of the Fiber-1 Protein Affects the Replication of Fowl Adenovirus Serotype 4
The Knob Domain of the Fiber-1 Protein Affects the Replication of Fowl Adenovirus Serotype 4
Fowl adenovirus serotype 4 (FAdV-4) outbreaks have caused significant economic losses in the Chinese poultry industry since 2015. The relationships among viral structural proteins ...
Lattice Boltzmann simulation of immiscible displacement in the complex micro-channel
Lattice Boltzmann simulation of immiscible displacement in the complex micro-channel
The immiscible displacement process in micro-channel, which widely existes in daily life and industrial production, is an important research subject. This subject is a typical cont...

