Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Comparison of sensitivity to beam collimation of the holographic shearing interferometer with the wedge plate shearing interferometer and the Talbot shearing interferometer

View through CrossRef
High sensitivity of collimation testing equipment is desirable where collimated beams are used for precise and accurate measurements. Precision in the setting of collimation depends on the sensitivity of the testing equipment. In the present work, sensitivity to beam collimation of the recently reported holographic shearing interferometer (HSI) [J. Opt. 20, 055603 (2018)JOOPDB0150-536X10.1088/2040-8986/aab6dc] is measured and compared with sensitivities of other collimation testing techniques based on the wedge plate shearing interferometer and the Talbot shearing interferometer. For a test beam of diameter 25 mm from an He–Ne laser and displacement of the collimating lens by 1 mm from the collimation position, the Talbot shearing interferometer shows a rotation of interference fringes from the horizontal direction by 2°, the wedge plate shearing interferometer shows 20°, and the HSI shows 25°. Sensitivity is also presented in terms of measured slopes of phase maps of the recorded interferograms for a 1 mm displacement of the collimating lens and is obtained as 0.98 mrad, 15 mrad, and 19 mrad corresponding to the Talbot shearing interferometer, the wedge plate shearing interferometer, and HSI, respectively. The effect of decollimation of the laser beam on the interference fringes of diffraction of the Lloyd mirror interferometer is also demonstrated. Theoretical concepts and experimental results are presented and discussed for the above-mentioned beam collimation testing techniques.
Title: Comparison of sensitivity to beam collimation of the holographic shearing interferometer with the wedge plate shearing interferometer and the Talbot shearing interferometer
Description:
High sensitivity of collimation testing equipment is desirable where collimated beams are used for precise and accurate measurements.
Precision in the setting of collimation depends on the sensitivity of the testing equipment.
In the present work, sensitivity to beam collimation of the recently reported holographic shearing interferometer (HSI) [J.
Opt.
20, 055603 (2018)JOOPDB0150-536X10.
1088/2040-8986/aab6dc] is measured and compared with sensitivities of other collimation testing techniques based on the wedge plate shearing interferometer and the Talbot shearing interferometer.
For a test beam of diameter 25 mm from an He–Ne laser and displacement of the collimating lens by 1 mm from the collimation position, the Talbot shearing interferometer shows a rotation of interference fringes from the horizontal direction by 2°, the wedge plate shearing interferometer shows 20°, and the HSI shows 25°.
Sensitivity is also presented in terms of measured slopes of phase maps of the recorded interferograms for a 1 mm displacement of the collimating lens and is obtained as 0.
98 mrad, 15 mrad, and 19 mrad corresponding to the Talbot shearing interferometer, the wedge plate shearing interferometer, and HSI, respectively.
The effect of decollimation of the laser beam on the interference fringes of diffraction of the Lloyd mirror interferometer is also demonstrated.
Theoretical concepts and experimental results are presented and discussed for the above-mentioned beam collimation testing techniques.

Related Results

2 mils Au wire interchip wedge bond cratering study
2 mils Au wire interchip wedge bond cratering study
Au wire thermosonic wedge bonding is applied for die to die interconnect on accelerometer device. With the fragile bond pad structure of MEMS device, bond pad cratering or bond pad...
Spatial phase-shifting polarization point-piffraction interferometer for wavefront measurement
Spatial phase-shifting polarization point-piffraction interferometer for wavefront measurement
Wavefront measurement is widely used in the field of optical manufacturing, military, astronomy, medical treatment, etc., and it reflects the performance of the optical system thro...
Optical Methods for the Measurement of the Temperature and Concentration Distribution in Combustion Chambers
Optical Methods for the Measurement of the Temperature and Concentration Distribution in Combustion Chambers
<div class="htmlview paragraph">Two kinds of optical methods for the measurement of the temperature and concentration distribution in combustion chambers by means of the real...
The Holographic Human for Surgical Navigation using Microsoft HoloLens
The Holographic Human for Surgical Navigation using Microsoft HoloLens
In surgical navigation, to accurately know the position of a surgical instrument in a patient's body is very important. Using transparent smart glasses is very useful for surgical ...
Foreland basin systems
Foreland basin systems
A foreland basin system is defined as: (a) an elongate region of potential sediment accommodation that forms on continental crust between a contractional orogenic belt and the adja...
Beam shaping optics to improve holographic and interferometric nanomanufacturing techniques
Beam shaping optics to improve holographic and interferometric nanomanufacturing techniques
Performance of various holographic and interferometric nanomanufacturing techniques can be essentially improved by homogenizing the intensity profile of the laser beam with using b...
Dosimetry of large wedged high‐energy photon beams
Dosimetry of large wedged high‐energy photon beams
The dependence of the wedge factor and central axis depth dose on field size was evaluated for 6‐, 10‐, and 24‐MV wedged photon beams for field sizes up to 40×40 cm2. The wedge fac...
Analisis Numerik Kuat Lentur Balok Support Beam Curve Tile Beton Semi Pracetak Dengan Variasi Panjang Bentangan
Analisis Numerik Kuat Lentur Balok Support Beam Curve Tile Beton Semi Pracetak Dengan Variasi Panjang Bentangan
Semi precast slab is a combination of precast concrete which consist of the support beam and curve tile with the cast in place concrete. During the working process, support beam wi...

Back to Top