Javascript must be enabled to continue!
Signal‐to‐noise ratio behavior of steady‐state free precession
View through CrossRef
AbstractSteady‐state free precession (SSFP) is a rapid gradient‐echo imaging technique that has recently gained popularity and is used in a variety of applications, including cardiac and real‐time imaging, because of its high signal and favorable contrast between blood and myocardium. The purpose of this work was to examine the signal‐to‐noise ratio (SNR) behavior of images acquired with SSFP, and the dependence of SNR on imaging parameters such as TR, bandwidth, and image resolution, and the use of multi‐echo sequences. In this work it is shown that the SNR of SSFP sequences is dependent only on pulse sequence efficiency, voxel dimensions, and relaxation parameters (T1 and T2). Notably, SNR is insensitive to bandwidth unless increases in bandwidth significantly decrease efficiency. Finally, we examined the relationship between pulse sequence performance (TR and efficiency) and gradient performance (maximum gradient strength and slew rate) for several imaging scenarios, including multi‐echo sequences, to determine the optimum matching of maximum gradient strength and slew rate for gradient hardware designs. For standard modern gradient hardware (40 mT/m and 150 mT/m/ms), we found that the maximum gradient strength is more than adequate for the imaging resolution that is commonly encountered with rapid scouting (3 mm × 4 mm × 10 mm voxel). It is well matched for typical CINE and real‐time cardiac imaging applications (1.5 mm × 2 mm × 6 mm voxel), and is inadequate for optimal matching with slew rate for high‐resolution applications such as musculoskeletal imaging (0.5 × 0.8 × 3 mm voxel). For the lower‐resolution methods, efficiency could be improved with higher slew rates; this provokes interest in designing methods for limiting dB/dt peripherally while achieving high switching rates in the imaging field of view. The use of multi‐echo SSFP acquisitions leads to substantial improvements in sequence performance (i.e., increased efficiency and shorter TR). Magn Reson Med 52:123–130, 2004. Published 2004 Wiley‐Liss, Inc.
Title: Signal‐to‐noise ratio behavior of steady‐state free precession
Description:
AbstractSteady‐state free precession (SSFP) is a rapid gradient‐echo imaging technique that has recently gained popularity and is used in a variety of applications, including cardiac and real‐time imaging, because of its high signal and favorable contrast between blood and myocardium.
The purpose of this work was to examine the signal‐to‐noise ratio (SNR) behavior of images acquired with SSFP, and the dependence of SNR on imaging parameters such as TR, bandwidth, and image resolution, and the use of multi‐echo sequences.
In this work it is shown that the SNR of SSFP sequences is dependent only on pulse sequence efficiency, voxel dimensions, and relaxation parameters (T1 and T2).
Notably, SNR is insensitive to bandwidth unless increases in bandwidth significantly decrease efficiency.
Finally, we examined the relationship between pulse sequence performance (TR and efficiency) and gradient performance (maximum gradient strength and slew rate) for several imaging scenarios, including multi‐echo sequences, to determine the optimum matching of maximum gradient strength and slew rate for gradient hardware designs.
For standard modern gradient hardware (40 mT/m and 150 mT/m/ms), we found that the maximum gradient strength is more than adequate for the imaging resolution that is commonly encountered with rapid scouting (3 mm × 4 mm × 10 mm voxel).
It is well matched for typical CINE and real‐time cardiac imaging applications (1.
5 mm × 2 mm × 6 mm voxel), and is inadequate for optimal matching with slew rate for high‐resolution applications such as musculoskeletal imaging (0.
5 × 0.
8 × 3 mm voxel).
For the lower‐resolution methods, efficiency could be improved with higher slew rates; this provokes interest in designing methods for limiting dB/dt peripherally while achieving high switching rates in the imaging field of view.
The use of multi‐echo SSFP acquisitions leads to substantial improvements in sequence performance (i.
e.
, increased efficiency and shorter TR).
Magn Reson Med 52:123–130, 2004.
Published 2004 Wiley‐Liss, Inc.
Related Results
Environmental History of Oceanic Noise Pollution
Environmental History of Oceanic Noise Pollution
The concept of “ocean noise” precedes the concept of “ocean noise pollution” by about half a century. Those seeking a body of scholarly literature on ocean noise as an environmenta...
Road traffic noise, noise sensitivity, noise annoyance, psychological and physical health and mortality
Road traffic noise, noise sensitivity, noise annoyance, psychological and physical health and mortality
Abstract
Background
Both physical and psychological health outcomes have been associated with exposure to environmental n...
Mechanism of suppressing noise intensity of squeezed state enhancement
Mechanism of suppressing noise intensity of squeezed state enhancement
This research focuses on advanced noise suppression technologies for high-precision measurement systems, particularly addressing the limitations of classical noise reducing approac...
Wind Turbine Noise Reduction from Seismological Data
Wind Turbine Noise Reduction from Seismological Data
<p>Over the last years, installations of wind turbines (WTs) increased worldwide. Owing to<br>negative effects on humans, WTs are often installed in are...
Frequency and bias dependent modeling of induced gate noise and cross-correlation noise in 40 nm metal-oxide-semiconductor field-effect transistors
Frequency and bias dependent modeling of induced gate noise and cross-correlation noise in 40 nm metal-oxide-semiconductor field-effect transistors
With the development of down-scaling of CMOS technology for low power, mixed-signal, and high frequency applications, the optimal high frequency performance is shown to be shifted ...
Geodetic Precession of the Sun, Solar System Planets, and their Satellites
Geodetic Precession of the Sun, Solar System Planets, and their Satellites
Abstract
The effect of the geodetic precession is the most significant relativistic effect in the rotation of celestial bodies. In this article, the new geodetic pre...
Estimating the Parameters of Extended Gravity Theories with the Schwarzschild Precession of S2 Star
Estimating the Parameters of Extended Gravity Theories with the Schwarzschild Precession of S2 Star
After giving a short overview of previous results on constraining of Extended Gravity by stellar orbits, we discuss the Schwarzschild orbital precession of S2 star assuming the con...
Interplay between Airy and Coriolis precessions in a real Foucault pendulum
Interplay between Airy and Coriolis precessions in a real Foucault pendulum
We study the precession of a Foucault pendulum using a new approach. We characterize the support anisotropy by the difference between the maximum and minimum periods of the pendulu...

