Purpose: To test an alternative method of visual acuity assessment by comparing habitual and best-corrected visual acuity by Snellen and Peek (a visual acuity testing smartphone application). Methods: A prospective study comparing visual acuity using Snellen's and Peek's visual acuity charts (smartphone-based applications). 162 eyes were assessed in this hospital-based setting by a single observer. Patients with gross ocular pathology and visual acuity less than 6/60 were excluded from the study. Results: There was no statistically significant difference between best corrected visual acuity by Snellens and Peeks'. Snellen's mean best corrected visual acuity was 0.9902 (±0.075), and Peek acuity was 0.9875 (±0.080). Conclusion: The visual acuity assessment by Peek is comparable to that of Snellen's; hence, it can be used as an excellent alternative to Snellens' visual acuity testing.
Creative Pharma Assent
Title: Comparison of smartphone based peek visual acuity with Snellen Visual Acuity
Description:
Purpose: To test an alternative method of visual acuity assessment by comparing habitual and best-corrected visual acuity by Snellen and Peek (a visual acuity testing smartphone application).
Methods: A prospective study comparing visual acuity using Snellen's and Peek's visual acuity charts (smartphone-based applications).
162 eyes were assessed in this hospital-based setting by a single observer.
Patients with gross ocular pathology and visual acuity less than 6/60 were excluded from the study.
Results: There was no statistically significant difference between best corrected visual acuity by Snellens and Peeks'.
Snellen's mean best corrected visual acuity was 0.
9902 (±0.
075), and Peek acuity was 0.
9875 (±0.
080).
Conclusion: The visual acuity assessment by Peek is comparable to that of Snellen's; hence, it can be used as an excellent alternative to Snellens' visual acuity testing.
Related Results
Perbandingan Hasil Pemeriksaan Tajam Penglihatan Jauh antara Aplikasi Perangkat Lunak Peek Acuity dengan Snellen Chart
Perbandingan Hasil Pemeriksaan Tajam Penglihatan Jauh antara Aplikasi Perangkat Lunak Peek Acuity dengan Snellen Chart
Pemeriksaan tajam penglihatan merupakan salah satu pemeriksaan terpenting untuk dapat menilai fungsi visual seseorang. Snellen chart adalah media yang paling sering digunakan untuk...
Biomechanical Analysis of Pullout Strengths of Rotator Cuff and Glenoid Anchors: 2011 Update
Biomechanical Analysis of Pullout Strengths of Rotator Cuff and Glenoid Anchors: 2011 Update
Purpose
To evaluate the biomechanical and design characteristics of newer suture anchors.
Methods
...
Comparison and analysis of measurements for crystallinity of PEEK and CF/PEEK composites
Comparison and analysis of measurements for crystallinity of PEEK and CF/PEEK composites
AbstractPEEK and CF/PEEK are two significant materials whose properties are intricately linked to their crystallization behavior. This study employed three analytical techniques—de...
The Best Phone Store, Intelligent Recommendation System for Smartphone Selection
The Best Phone Store, Intelligent Recommendation System for Smartphone Selection
Abstract— Nowadays, smartphones are a primary item that is needed by almost everyone, from children to adults. The large number of smartphones on the market makes it difficult for ...
Study on microstructures and mechanical performance of laser transmission welding of poly-ether-ether-ketone (PEEK) and carbon fiber reinforced PEEK (CFR-PEEK)
Study on microstructures and mechanical performance of laser transmission welding of poly-ether-ether-ketone (PEEK) and carbon fiber reinforced PEEK (CFR-PEEK)
The reliable assembly of poly-ether-ether-ketone (PEEK) and carbon fiber-reinforced PEEK (CFR-PEEK) is crucial to effective load transfer within lightweight and high-stiffness stru...
In vitro physicochemical and biological properties of titanium alloy, zirconia, polyetheretherketone, and carbon fiber-reinforced polyetheretherketone
In vitro physicochemical and biological properties of titanium alloy, zirconia, polyetheretherketone, and carbon fiber-reinforced polyetheretherketone
Implant repair is a common means to restore the normal function of the hard tissues (bone or teeth). At present, the commonly and potentially used implant materials include titaniu...
Análisis de fatiga y flexión sobre implantes monoblock de PEEK y la unión pilar PEEK-implante de titanio
Análisis de fatiga y flexión sobre implantes monoblock de PEEK y la unión pilar PEEK-implante de titanio
En este trabajo de tesis doctoral se analizaron las fuerzas de flexión y fatiga sobre implantes dentales monoblock de PEEK y también la unión pilar PEEK - implante de titanio es un...
Validity of the Titmus Vision Screener: A Comparison with the Snellen Chart
Validity of the Titmus Vision Screener: A Comparison with the Snellen Chart
Given limited knowledge regarding validity of the Titmus vision screener, we sought to compare visual acuity measurements obtained from the Titmus with that from the Snellen chart ...