Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

The comparison of white-to-white via triple person-times caliper measuring and machine- measuring in V4c implantable collamer lens implantation

View through CrossRef
Abstract Background: This study aimed to compare the differences in white-to-white (WTW) values obtained using the triple-person-times caliper measurement, IOL-Master 700, Pentacam HR, and UBM before V4c Implantable Collamer Lens (ICL) Implantation. The objective of this study was to analyze the characteristics of these measurements and assess their correlation with the vault. Methods: A total of 930 myopia patients (1842 eyes) who were interested in undergoing ICL surgery were assessed before the procedure using various instruments. The WTW measurements were obtained using a triple person-times caliper, Pentacam HR, and IOL-Master 700, whereas the angle-to-angle (ATA) measurements were obtained using UBM. The size of the ICL was subsequently calculated using triple person-times caliper measurements. The vault of the ICL was assessed using Pentacam HR three months after the surgery. Results: The WTW was determined to be 11.31 ± 0.31mm, 11.49 ± 0.34mm, and11.86 ± 0.37mm, respectively, using the triple person-times caliper, Pentacam HR, and IOL-Master 700. The measurement of ATA was 11.58 ± 0.51mm, as done by UBM. The ICL vault was measured to be 411.49 ± 197.59 µm when examined with Pentacam HR three months after the procedure. The results from all four methods in horizontal WTW, triple person-times caliper, Pentacam HR, IOL - Master 700, and UBM, were compared and p < 0.001 was considered statistically significant. The four measures correlated well (r > 0.38, p = 0.000). The highest correlation was found between IOL-Master and Pentacam HR (r = 0.783, p = 0.00). The lowest correlation was found between UBM and Pentacam HR (r = 0.38, p = 0.00). Bland–Altman analysis showed that the 95% limits of agreement (LoA) were the triple person-times caliper and Pentacam HR (–0.59, 0.29) and the triple person-times caliper and IOL Master (–1.12,–0.03). This indicated a strong agreement between the triple person-times caliper and Pentacam HR and a lack of agreement between the triple person-times caliper and IOL Master. Conclusions: Triple person-times caliper measurements offer excellent maneuverability, practicality, and reliable outcomes for determining ICL vaults. Measurements obtained using the triple-person caliper were less differece than those obtained using the Pentacam HR.
Title: The comparison of white-to-white via triple person-times caliper measuring and machine- measuring in V4c implantable collamer lens implantation
Description:
Abstract Background: This study aimed to compare the differences in white-to-white (WTW) values obtained using the triple-person-times caliper measurement, IOL-Master 700, Pentacam HR, and UBM before V4c Implantable Collamer Lens (ICL) Implantation.
The objective of this study was to analyze the characteristics of these measurements and assess their correlation with the vault.
Methods: A total of 930 myopia patients (1842 eyes) who were interested in undergoing ICL surgery were assessed before the procedure using various instruments.
The WTW measurements were obtained using a triple person-times caliper, Pentacam HR, and IOL-Master 700, whereas the angle-to-angle (ATA) measurements were obtained using UBM.
The size of the ICL was subsequently calculated using triple person-times caliper measurements.
The vault of the ICL was assessed using Pentacam HR three months after the surgery.
Results: The WTW was determined to be 11.
31 ± 0.
31mm, 11.
49 ± 0.
34mm, and11.
86 ± 0.
37mm, respectively, using the triple person-times caliper, Pentacam HR, and IOL-Master 700.
The measurement of ATA was 11.
58 ± 0.
51mm, as done by UBM.
The ICL vault was measured to be 411.
49 ± 197.
59 µm when examined with Pentacam HR three months after the procedure.
The results from all four methods in horizontal WTW, triple person-times caliper, Pentacam HR, IOL - Master 700, and UBM, were compared and p < 0.
001 was considered statistically significant.
The four measures correlated well (r > 0.
38, p = 0.
000).
The highest correlation was found between IOL-Master and Pentacam HR (r = 0.
783, p = 0.
00).
The lowest correlation was found between UBM and Pentacam HR (r = 0.
38, p = 0.
00).
Bland–Altman analysis showed that the 95% limits of agreement (LoA) were the triple person-times caliper and Pentacam HR (–0.
59, 0.
29) and the triple person-times caliper and IOL Master (–1.
12,–0.
03).
This indicated a strong agreement between the triple person-times caliper and Pentacam HR and a lack of agreement between the triple person-times caliper and IOL Master.
Conclusions: Triple person-times caliper measurements offer excellent maneuverability, practicality, and reliable outcomes for determining ICL vaults.
Measurements obtained using the triple-person caliper were less differece than those obtained using the Pentacam HR.

Related Results

Hubungan Perilaku Pola Makan dengan Kejadian Anak Obesitas
Hubungan Perilaku Pola Makan dengan Kejadian Anak Obesitas
<p><em><span style="font-size: 11.0pt; font-family: 'Times New Roman',serif; mso-fareast-font-family: 'Times New Roman'; mso-ansi-language: EN-US; mso-fareast-langua...
Implantable collamer lens with a central hole for residual refractive error correction after corneal refractive surgery
Implantable collamer lens with a central hole for residual refractive error correction after corneal refractive surgery
Abstract PURPOSE: To assess the visual and refractive outcomes of an implantable collamer lens with a central hole (ICL V4c) for residual refractive error correction after ...
Refractive outcomes after V4c Toric collamer lens implantation over 1y of follow-up
Refractive outcomes after V4c Toric collamer lens implantation over 1y of follow-up
AIM: To evaluate refractive outcomes and corneal astigmatism changes after Toric implantable collamer lens with a central port (V4c T-ICL) implantation over 1y of follow-up. METHOD...
Osoby niejednokrotnie przebywające w izbie wytrzeźwień
Osoby niejednokrotnie przebywające w izbie wytrzeźwień
In Poland we have at present in towns 29 detoxication centres with 1,226 beds; people found by the police in public places in a state of intoxication are more and more often taken ...

Back to Top