Javascript must be enabled to continue!
COMPARISON TENSILE STRENGTH OF NATURAL AND SYNTHETIC ABSORBABLE SUTURES
View through CrossRef
Objective: The aim of the investigation is to evaluate and to compare the tensile strength of commercial natural and synthetic absorbable suturematerials currently used in surgery. The natural absorbable sutures of chromic catgut are prepared for this purpose as well as commercial syntheticabsorbable sutures made from polyglycolide.Methods: The analysis has been carried out following the standard test method for tensile strength and Young’s modulus of fiber ASTM C1557-03.Measuring the diameter of each suture has been carried out with an optical microscope to determine the accuracy of manufacturers’ data. Tensiletesting has been performed to evaluate the tensile strength of each type of sutures. The modulus elasticity and strain (ϵ) obtained are also presented.Results: The results show that sutures made from braided synthetic material of polyglycolide (violet coated) present a tensile strength remarkablysuperior (1070.292 MPa) to that of natural absorbable sutures of chromic catgut (392.276 MPa). Using optical macro microscope analysis,monofilament sutures present less surface irregularities than multifilament polyglycolide sutures. Chromic catgut monofilament sutures present lesssurface irregularities than multifilament polyglycolide.Conclusion: Tensile test of absorbable sutures was conducted in this research. Two types of absorbable sutures were investigated and compared. It isfound that sutures made from braided synthetic material of polyglycolide (violet coated) having much better tensile strength comparing with suturesmade from natural material (chromic catgut monofilament).
Innovare Academic Sciences Pvt Ltd
Title: COMPARISON TENSILE STRENGTH OF NATURAL AND SYNTHETIC ABSORBABLE SUTURES
Description:
Objective: The aim of the investigation is to evaluate and to compare the tensile strength of commercial natural and synthetic absorbable suturematerials currently used in surgery.
The natural absorbable sutures of chromic catgut are prepared for this purpose as well as commercial syntheticabsorbable sutures made from polyglycolide.
Methods: The analysis has been carried out following the standard test method for tensile strength and Young’s modulus of fiber ASTM C1557-03.
Measuring the diameter of each suture has been carried out with an optical microscope to determine the accuracy of manufacturers’ data.
Tensiletesting has been performed to evaluate the tensile strength of each type of sutures.
The modulus elasticity and strain (ϵ) obtained are also presented.
Results: The results show that sutures made from braided synthetic material of polyglycolide (violet coated) present a tensile strength remarkablysuperior (1070.
292 MPa) to that of natural absorbable sutures of chromic catgut (392.
276 MPa).
Using optical macro microscope analysis,monofilament sutures present less surface irregularities than multifilament polyglycolide sutures.
Chromic catgut monofilament sutures present lesssurface irregularities than multifilament polyglycolide.
Conclusion: Tensile test of absorbable sutures was conducted in this research.
Two types of absorbable sutures were investigated and compared.
It isfound that sutures made from braided synthetic material of polyglycolide (violet coated) having much better tensile strength comparing with suturesmade from natural material (chromic catgut monofilament).
Related Results
Use of Absorbable Cutaneous Sutures Amid the COVID-19 Pandemic
Use of Absorbable Cutaneous Sutures Amid the COVID-19 Pandemic
The use of absorbable epicuticular sutures is highlighted as a measure to decrease the number of patient visits, eliminating the risk of additional exposures for patients and medic...
Groin hernia repair : evaluation of clinical impacts and interactions of mesh and mesh fixation
Groin hernia repair : evaluation of clinical impacts and interactions of mesh and mesh fixation
<p dir="ltr">AIMS</p><p dir="ltr">The project underlying this thesis aimed to identify and quantify relative risk differences in reoperation rate (Papers I and II...
Groin hernia repair : evaluation of clinical impacts and interactions of mesh and mesh fixation
Groin hernia repair : evaluation of clinical impacts and interactions of mesh and mesh fixation
<p dir="ltr">AIMS</p><p dir="ltr">The project underlying this thesis aimed to identify and quantify relative risk differences in reoperation rate (Papers I and II...
Hernia surgery : evaluation of the clinical impacts and interactions of mesh and mesh fixation
Hernia surgery : evaluation of the clinical impacts and interactions of mesh and mesh fixation
<p dir="ltr">AIMS</p><p dir="ltr">The project underlying this thesis aimed to identify and quantify relative risk differences in reoperation rate (Papers I and II...
Coated Surgical Sutures: Nanoparticles and nanocomposite as coating materials for absorbable and nonabsorbable wound closure devices
Coated Surgical Sutures: Nanoparticles and nanocomposite as coating materials for absorbable and nonabsorbable wound closure devices
Abstract
Upgrading the surgical sutures, as the main wound closure device, is essential. The evolution of bacterial resistance and the plummeting of antibiotics have direct...
Comparative Study of Tensile Strength in Vicryl™ vs. Prolene™ 5-0 Knots: Impact of Throw Type and Count
Comparative Study of Tensile Strength in Vicryl™ vs. Prolene™ 5-0 Knots: Impact of Throw Type and Count
Abstract
Background
Knots are the weakest point of sutures, making their security and tensile strength critical. While suture ma...
Asteroid Regolith Strength Modelling Informed by Bennu Sample Measurements
Asteroid Regolith Strength Modelling Informed by Bennu Sample Measurements
Abstract Informed by findings about the sample from asteroid Bennu, we apply a new simulation methodology to better understand how Van der Waals (VdW) forces work between spherical...
Biomechanical assessment of suture techniques used for tendon repair
Biomechanical assessment of suture techniques used for tendon repair
Abstract
Objective: The aim of this study was to assess different tendon suture techniques from the perspectives of both tensile strength and early active mobilization. \r\nMethod...