Optimization of Centrifugal Pump Characteristic Dimensions for Mechanical Circulatory Support Devices
View through CrossRef
The application of artificial mechanical pumps as heart assist devices impose power and size limitations on the pumping mechanism, and therefore requires careful optimization of pump characteristics. Typically new pumps are designed by relying on the performance of other previously designed pumps of known performance using concepts of fluid dynamic similarity. Such data are readily available for industrial pumps, which operate in Reynolds numbers region of 108. Heart assist pumps operate in Reynolds numbers of 105. There are few data available for the design of centrifugal pumps in this characteristic range. This article develops specific speed versus specific diameter graphs suitable for the design and optimization of these smaller centrifugal pumps concentrating in dimensions suitable for ventricular assist devices (VADs) and mechanical circulatory support (MCS) devices. A combination of experimental and numerical techniques was used to measure and analyze the performance of 100 optimized pumps designed for this application. The data are presented in the traditional Cordier diagram of nondimensional specific speed versus specific diameter. Using these data, nine efficient designs were selected to be manufactured and tested in different operating conditions of flow, pressure, and rotational speed. The nondimensional results presented in this article enable preliminary design of centrifugal pumps for VADs and MCS devices.
Ovid Technologies (Wolters Kluwer Health)
Title: Optimization of Centrifugal Pump Characteristic Dimensions for Mechanical Circulatory Support Devices
Description:
The application of artificial mechanical pumps as heart assist devices impose power and size limitations on the pumping mechanism, and therefore requires careful optimization of pump characteristics.
Typically new pumps are designed by relying on the performance of other previously designed pumps of known performance using concepts of fluid dynamic similarity.
Such data are readily available for industrial pumps, which operate in Reynolds numbers region of 108.
Heart assist pumps operate in Reynolds numbers of 105.
There are few data available for the design of centrifugal pumps in this characteristic range.
This article develops specific speed versus specific diameter graphs suitable for the design and optimization of these smaller centrifugal pumps concentrating in dimensions suitable for ventricular assist devices (VADs) and mechanical circulatory support (MCS) devices.
A combination of experimental and numerical techniques was used to measure and analyze the performance of 100 optimized pumps designed for this application.
The data are presented in the traditional Cordier diagram of nondimensional specific speed versus specific diameter.
Using these data, nine efficient designs were selected to be manufactured and tested in different operating conditions of flow, pressure, and rotational speed.
The nondimensional results presented in this article enable preliminary design of centrifugal pumps for VADs and MCS devices.
Related Results
Integrated switchable ventricular assist devices for pediatric patients
Integrated switchable ventricular assist devices for pediatric patients
Thousands of children are born each year with significant cardiac defects that result in the development of heart disease and ultimately premature congestive heart failure (CHF). I...
Serum Myoglobin After Cardiac Surgery Predicts Postoperative Cardiogenic Shock Requiring Mechanical Circulatory Support Within 14 Days
Serum Myoglobin After Cardiac Surgery Predicts Postoperative Cardiogenic Shock Requiring Mechanical Circulatory Support Within 14 Days
Background:
Cardiogenic shock requiring mechanical circulatory support is a life-threatening complication of cardiac surgery with cardiopulmonary bypass (CPB). ...
Series multi-blood pump with dual activation for pediatric patients with heart failure
Series multi-blood pump with dual activation for pediatric patients with heart failure
Pediatric heart failure (HF), arising from both congenital and acquired disorders, is a serious pathology that affects thousands of children each year. Severe cases of pediatric HF...
Study on custom centrifugal pump performance in supplying food based high viscos liquid
Study on custom centrifugal pump performance in supplying food based high viscos liquid
Viscosity is one of the factors affecting the performance of the centrifugal pump. A centrifugal pump is a device that used driven motor called impeller to move fluid by rotational...
INVESTIGATION OF THE ENERGY CHARACTERISTICS OF CENTRIFUGAL PUMPS
INVESTIGATION OF THE ENERGY CHARACTERISTICS OF CENTRIFUGAL PUMPS
A hydraulic device that is used to suck up liquid, move it under pressure or pump it, is called a pump. As a rule, any movement of a liquid by similar aggregates is carried out due...
Novel integrated pediatric total artificial heart
Novel integrated pediatric total artificial heart
Four million live births occur in the US each year, and 25% of those babies are born with a congenital heart defect requiring treatment. Of that cohort, approximately 40,000 are bo...
Modeling and Optimal Control of a Variable-Speed Centrifugal Pump With a Pipeline
Modeling and Optimal Control of a Variable-Speed Centrifugal Pump With a Pipeline
Pumping processes often require different operating conditions for the same pipeline. The conditions downstream in the pipeline can change in such a way that the pressure at the di...
ANALISIS PERFORMANCE POMPA FEED SENTRIFUGAL
ANALISIS PERFORMANCE POMPA FEED SENTRIFUGAL
To support the optimization of operations at a refinery, a tool is urgently needed that can help process crude oil into a product. The centrifugal feed pump P-100/4 is a pump that ...