Optimization of Centrifugal Pump Characteristic Dimensions for Mechanical Circulatory Support Devices
View through CrossRef
The application of artificial mechanical pumps as heart assist devices impose power and size limitations on the pumping mechanism, and therefore requires careful optimization of pump characteristics. Typically new pumps are designed by relying on the performance of other previously designed pumps of known performance using concepts of fluid dynamic similarity. Such data are readily available for industrial pumps, which operate in Reynolds numbers region of 108. Heart assist pumps operate in Reynolds numbers of 105. There are few data available for the design of centrifugal pumps in this characteristic range. This article develops specific speed versus specific diameter graphs suitable for the design and optimization of these smaller centrifugal pumps concentrating in dimensions suitable for ventricular assist devices (VADs) and mechanical circulatory support (MCS) devices. A combination of experimental and numerical techniques was used to measure and analyze the performance of 100 optimized pumps designed for this application. The data are presented in the traditional Cordier diagram of nondimensional specific speed versus specific diameter. Using these data, nine efficient designs were selected to be manufactured and tested in different operating conditions of flow, pressure, and rotational speed. The nondimensional results presented in this article enable preliminary design of centrifugal pumps for VADs and MCS devices.
Ovid Technologies (Wolters Kluwer Health)
Title: Optimization of Centrifugal Pump Characteristic Dimensions for Mechanical Circulatory Support Devices
Description:
The application of artificial mechanical pumps as heart assist devices impose power and size limitations on the pumping mechanism, and therefore requires careful optimization of pump characteristics.
Typically new pumps are designed by relying on the performance of other previously designed pumps of known performance using concepts of fluid dynamic similarity.
Such data are readily available for industrial pumps, which operate in Reynolds numbers region of 108.
Heart assist pumps operate in Reynolds numbers of 105.
There are few data available for the design of centrifugal pumps in this characteristic range.
This article develops specific speed versus specific diameter graphs suitable for the design and optimization of these smaller centrifugal pumps concentrating in dimensions suitable for ventricular assist devices (VADs) and mechanical circulatory support (MCS) devices.
A combination of experimental and numerical techniques was used to measure and analyze the performance of 100 optimized pumps designed for this application.
The data are presented in the traditional Cordier diagram of nondimensional specific speed versus specific diameter.
Using these data, nine efficient designs were selected to be manufactured and tested in different operating conditions of flow, pressure, and rotational speed.
The nondimensional results presented in this article enable preliminary design of centrifugal pumps for VADs and MCS devices.
Related Results
619. Pharmacokinetic-Pharmacodynamic (PK-PD) Target Attainment Analyses to Support Epetraborole Dose Selection for the Treatment of Patients with Mycobacterium avium Complex (MAC) Lung Disease
619. Pharmacokinetic-Pharmacodynamic (PK-PD) Target Attainment Analyses to Support Epetraborole Dose Selection for the Treatment of Patients with Mycobacterium avium Complex (MAC) Lung Disease
Abstract
Background
Epetraborole (EBO) is an orally available, bacterial leucyl transfer RNA synthetase inhibitor that concentra...
LB2306. Population Pharmacokinetic (PPK), Pharmacokinetic/Pharmacodynamic attainment (PTA), and Clinical Pharmacokinetic/Pharmacodynamic (PK/PD) Analyses for Sulbactam-Durlobactam (SUL-DUR) to Support Dose Selection for the Treatment of Acinetobacter baum
LB2306. Population Pharmacokinetic (PPK), Pharmacokinetic/Pharmacodynamic attainment (PTA), and Clinical Pharmacokinetic/Pharmacodynamic (PK/PD) Analyses for Sulbactam-Durlobactam (SUL-DUR) to Support Dose Selection for the Treatment of Acinetobacter baum
Abstract
Background
SUL-DUR is a β-lactam/β-lactamase inhibitor combination in development for the treatment of ABC infections, ...
593. Population Pharmacokinetic Model Development for Epetraborole and Mycobacterium avium Complex (MAC) Lung Disease Patients Using Data from Phase 1 and 2 Studies
593. Population Pharmacokinetic Model Development for Epetraborole and Mycobacterium avium Complex (MAC) Lung Disease Patients Using Data from Phase 1 and 2 Studies
Abstract
Background
Epetraborole (EBO), an orally available bacterial leucyl transfer RNA synthetase inhibitor with potent activ...
592. Impact of Elevated MIC Values on Echinocandin Pharmacokinetic-Pharmacodynamic (PK-PD) Candida glabrata Target Attainment (TA)
592. Impact of Elevated MIC Values on Echinocandin Pharmacokinetic-Pharmacodynamic (PK-PD) Candida glabrata Target Attainment (TA)
Abstract
Background
Given the increasing prevalence of non-albicans Candida species, including C. glabrata and C. auris, which h...
Integrated switchable ventricular assist devices for pediatric patients
Integrated switchable ventricular assist devices for pediatric patients
Thousands of children are born each year with significant cardiac defects that result in the development of heart disease and ultimately premature congestive heart failure (CHF). I...
Serum Myoglobin After Cardiac Surgery Predicts Postoperative Cardiogenic Shock Requiring Mechanical Circulatory Support Within 14 Days
Serum Myoglobin After Cardiac Surgery Predicts Postoperative Cardiogenic Shock Requiring Mechanical Circulatory Support Within 14 Days
Background:
Cardiogenic shock requiring mechanical circulatory support is a life-threatening complication of cardiac surgery with cardiopulmonary bypass (CPB). ...
Study on custom centrifugal pump performance in supplying food based high viscos liquid
Study on custom centrifugal pump performance in supplying food based high viscos liquid
Viscosity is one of the factors affecting the performance of the centrifugal pump. A centrifugal pump is a device that used driven motor called impeller to move fluid by rotational...
Series multi-blood pump with dual activation for pediatric patients with heart failure
Series multi-blood pump with dual activation for pediatric patients with heart failure
Pediatric heart failure (HF), arising from both congenital and acquired disorders, is a serious pathology that affects thousands of children each year. Severe cases of pediatric HF...