Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Overcoming fouling challenges in ultrafiltration for drinking water treatment

View through CrossRef
Abstract Ultrafiltration-based-membrane technology has been introduced as a viable and promising solution in drinking water treatment and wastewater reuse applications. However, in this technology membrane fouling presents a crucial challenge hindering its widespread use and sustainability. Membrane fouling increases the operational costs and decreases membrane lifetime due to backwashing, chemical cleaning, and ultimately membrane replacement in a shorter time. Ultrafiltration reversible fouling can be removed by reversing backwashing and chemical cleaning of membrane pores, on the other hand, irreversible fouling is persistent and membrane flux is not restored to its original state. An extensive understanding of reversible and irreversible fouling mitigation still needs more investigation. This review will focus on the technologies and methods used in controlling UF fouling and conclude the most effective method for UF fouling mitigation. The fundamentals of fouling are addressed, the methods of reversible and irreversible fouling control are summarized, factors that influence fouling are presented, and the results of controlling fouling methods are illustrated and discussed to conclude the most effective method for mitigating UF fouling. This review found that coagulation with an aiding coagulant and alternate disinfection such as chlorine dioxide and potassium ferrate were promising technologies as a pretreatment to mitigate ultrafiltration fouling.
Title: Overcoming fouling challenges in ultrafiltration for drinking water treatment
Description:
Abstract Ultrafiltration-based-membrane technology has been introduced as a viable and promising solution in drinking water treatment and wastewater reuse applications.
However, in this technology membrane fouling presents a crucial challenge hindering its widespread use and sustainability.
Membrane fouling increases the operational costs and decreases membrane lifetime due to backwashing, chemical cleaning, and ultimately membrane replacement in a shorter time.
Ultrafiltration reversible fouling can be removed by reversing backwashing and chemical cleaning of membrane pores, on the other hand, irreversible fouling is persistent and membrane flux is not restored to its original state.
An extensive understanding of reversible and irreversible fouling mitigation still needs more investigation.
This review will focus on the technologies and methods used in controlling UF fouling and conclude the most effective method for UF fouling mitigation.
The fundamentals of fouling are addressed, the methods of reversible and irreversible fouling control are summarized, factors that influence fouling are presented, and the results of controlling fouling methods are illustrated and discussed to conclude the most effective method for mitigating UF fouling.
This review found that coagulation with an aiding coagulant and alternate disinfection such as chlorine dioxide and potassium ferrate were promising technologies as a pretreatment to mitigate ultrafiltration fouling.

Related Results

PREDICTION ANALYSIS OF FOULING MODEL ON HEAT EXCHANGER IN THE CRUDE OIL REFINERY
PREDICTION ANALYSIS OF FOULING MODEL ON HEAT EXCHANGER IN THE CRUDE OIL REFINERY
Fouling mainly occurs in the oil industry. Fouling is an unwanted deposit in HE (heat exchanger). Reliable fouling models are scarce, although empirical and theoretical models have...
In vitro evaluation of critical ultrafiltration fluxes and transmembrane pressure in a high flux dialyzer
In vitro evaluation of critical ultrafiltration fluxes and transmembrane pressure in a high flux dialyzer
Abstract In patients treated with haemodiafiltration, high convection volumes are considered beneficial. However it leads to pressure instability and membrane fouling. We a...
In vitro evaluation of critical ultrafiltration fluxes and transmembrane pressure in a high flux dialyzer
In vitro evaluation of critical ultrafiltration fluxes and transmembrane pressure in a high flux dialyzer
Abstract In patients treated with haemodiafiltration, high convection volumes are considered beneficial. However it leads to pressure instabi...
Experimental Analyses and Modeling of Ultrasound-Assisted Fouling Control in Ultrafiltration
Experimental Analyses and Modeling of Ultrasound-Assisted Fouling Control in Ultrafiltration
<p dir="ltr">Membrane fouling presents a prevalent challenge in filtration processes, frequently requiring cleaning procedures that can result in system downtime, lost produc...
Experimental Analyses and Modeling of Ultrasound-Assisted Fouling Control in Ultrafiltration
Experimental Analyses and Modeling of Ultrasound-Assisted Fouling Control in Ultrafiltration
<p dir="ltr">Membrane fouling presents a prevalent challenge in filtration processes, frequently requiring cleaning procedures that can result in system downtime, lost produc...
Uncertainty Modeling of Fouling Thickness and Morphology on Compressor Blade
Uncertainty Modeling of Fouling Thickness and Morphology on Compressor Blade
To describe the fouling characteristics of compressor blades, fouling is categorized into dense and loose layers to characterize thickness and rough structures. An uncertainty mode...
Fouling Monitoring on Process Centrifugal Compressors
Fouling Monitoring on Process Centrifugal Compressors
Abstract Oil and gas plants handle large quantities of gas through the deployment of centrifugal compressors. For this reason, they can be considered critical machin...

Back to Top