Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

PREDICTION ANALYSIS OF FOULING MODEL ON HEAT EXCHANGER IN THE CRUDE OIL REFINERY

View through CrossRef
Fouling mainly occurs in the oil industry. Fouling is an unwanted deposit in HE (heat exchanger). Reliable fouling models are scarce, although empirical and theoretical models have been proposed to describe fouling in heat exchangers. The general models of empirical fouling used are linear, falling rate, and asymptotic. The research methodology begins with the acquisition and use of operational fouling data, which is then followed by the use of an asymptotic fouling model and ends with calculating the thickness of fouling in all HE. The object of this research study is all HE in the crude oil refinery HEN (heat exchanger network). The aim of this research is to use the asymptotic fouling model and get the fouling thickness. The fouling resistance from time to time increases, but in the end, it tends to be stationary, where for the final value, the highest fouling resistance is in HE-10, namely 14.8E-03 (m2°C/W), and the lowest value is fouling resistance at HE- 01 is 1.27E-03 (m2°C/W). The thickness of HE fouling in asymptotic conditions indicates that HE undergoes the same deposition process as suppression.Keywords: fouling, heat exchanger, asymptotic, crude oil refinery, heat exchanger network
Title: PREDICTION ANALYSIS OF FOULING MODEL ON HEAT EXCHANGER IN THE CRUDE OIL REFINERY
Description:
Fouling mainly occurs in the oil industry.
Fouling is an unwanted deposit in HE (heat exchanger).
Reliable fouling models are scarce, although empirical and theoretical models have been proposed to describe fouling in heat exchangers.
The general models of empirical fouling used are linear, falling rate, and asymptotic.
The research methodology begins with the acquisition and use of operational fouling data, which is then followed by the use of an asymptotic fouling model and ends with calculating the thickness of fouling in all HE.
The object of this research study is all HE in the crude oil refinery HEN (heat exchanger network).
The aim of this research is to use the asymptotic fouling model and get the fouling thickness.
The fouling resistance from time to time increases, but in the end, it tends to be stationary, where for the final value, the highest fouling resistance is in HE-10, namely 14.
8E-03 (m2°C/W), and the lowest value is fouling resistance at HE- 01 is 1.
27E-03 (m2°C/W).
The thickness of HE fouling in asymptotic conditions indicates that HE undergoes the same deposition process as suppression.
Keywords: fouling, heat exchanger, asymptotic, crude oil refinery, heat exchanger network.

Related Results

Crude Oil Characterization For Micellar Enhanced Oil Recovery
Crude Oil Characterization For Micellar Enhanced Oil Recovery
Abstract Chemically enhanced oil recovery depends on the phase and interfacial properties of the crude phase and interfacial properties of the crude Oil-brine-sur...
Parametric Modeling and Economic Analysis of a 2MWth 3-Stream sCO2 Heat Exchanger
Parametric Modeling and Economic Analysis of a 2MWth 3-Stream sCO2 Heat Exchanger
Abstract This paper presents the design and cost optimization of a novel 2MWth 3-stream sCO2 plate-fin heat exchanger. This heat exchanger design is unique in that i...
Crude Oil and Crude Oil Derivatives Transactions by Oil and Gas Producers.
Crude Oil and Crude Oil Derivatives Transactions by Oil and Gas Producers.
This study attempts to resolve two important issues. First, it investigates the diversification benefit of crude oil for equities. Second, it examines whether or not crude oil deri...
Impossible to Possible - Decommissioning the UAE's Oldest Oil Refinery with Zero Flaring
Impossible to Possible - Decommissioning the UAE's Oldest Oil Refinery with Zero Flaring
Abstract Decommissioning of Oil Refinery is not a regular affair, hence information on best practices being followed during facility decommissioning is not available...
Kaji efisiensi temperatur penukar panas dengan variasi aliran untuk aplikasi pengering
Kaji efisiensi temperatur penukar panas dengan variasi aliran untuk aplikasi pengering
Abstrak Heat exchanger atau alat penukar panas adalah alat-alat yang digunakan untuk mengubah temperatur fluida atau mengubah fasa fluida dengan cara mempertukarkan panasnya dengan...
Crude Oil Refining Processes
Crude Oil Refining Processes
This chapter introduces and discusses the major processes used for refining crude oil. After a brief historical perspective of crude oil refining, refinery objectives are introduce...
The After Effect of Crude Oil Spillage on Some Associated Heavy Metals in the Soil
The After Effect of Crude Oil Spillage on Some Associated Heavy Metals in the Soil
Abstract Crude oil spillage is one major means of environmental pollution in oil and gas exploration and production. Since 1976, about 5334 cases of crude oil spi...
Fouling and Mechanism
Fouling and Mechanism
Fouling is the deposition of material on the heat transfer surface which reduces the film heat transfer coefficient. The impact of fouling on the heat exchanger is manifested as th...

Back to Top