Javascript must be enabled to continue!
Filtered backprojection proton CT reconstruction along most likely paths
View through CrossRef
Purpose:Proton CT (pCT) has the potential to accurately measure the electron density map of tissues at low doses but the spatial resolution is prohibitive if the curved paths of protons in matter is not accounted for. The authors propose to account for an estimate of the most likely path of protons in a filtered backprojection (FBP) reconstruction algorithm.Methods:The energy loss of protons is first binned in several proton radiographs at different distances to the proton source to exploit the depth‐dependency of the estimate of the most likely path. This process is named the distance‐driven binning. A voxel‐specific backprojection is then used to select the adequate radiograph in the distance‐driven binning in order to propagate in the pCT image the best achievable spatial resolution in proton radiographs. The improvement in spatial resolution is demonstrated using Monte Carlo simulations of resolution phantoms.Results:The spatial resolution in the distance‐driven binning depended on the distance of the objects from the source and was optimal in the binned radiograph corresponding to that distance. The spatial resolution in the reconstructed pCT images decreased with the depth in the scanned object but it was always better than previous FBP algorithms assuming straight line paths. In a water cylinder with 20 cm diameter, the observed range of spatial resolutions was 0.7 − 1.6 mm compared to 1.0 − 2.4 mm at best with a straight line path assumption. The improvement was strongly enhanced in shorter 200° scans.Conclusions:Improved spatial resolution was obtained in pCT images with filtered backprojection reconstruction using most likely path estimates of protons. The improvement in spatial resolution combined with the practicality of FBP algorithms compared to iterative reconstruction algorithms makes this new algorithm a candidate of choice for clinical pCT.
Title: Filtered backprojection proton CT reconstruction along most likely paths
Description:
Purpose:Proton CT (pCT) has the potential to accurately measure the electron density map of tissues at low doses but the spatial resolution is prohibitive if the curved paths of protons in matter is not accounted for.
The authors propose to account for an estimate of the most likely path of protons in a filtered backprojection (FBP) reconstruction algorithm.
Methods:The energy loss of protons is first binned in several proton radiographs at different distances to the proton source to exploit the depth‐dependency of the estimate of the most likely path.
This process is named the distance‐driven binning.
A voxel‐specific backprojection is then used to select the adequate radiograph in the distance‐driven binning in order to propagate in the pCT image the best achievable spatial resolution in proton radiographs.
The improvement in spatial resolution is demonstrated using Monte Carlo simulations of resolution phantoms.
Results:The spatial resolution in the distance‐driven binning depended on the distance of the objects from the source and was optimal in the binned radiograph corresponding to that distance.
The spatial resolution in the reconstructed pCT images decreased with the depth in the scanned object but it was always better than previous FBP algorithms assuming straight line paths.
In a water cylinder with 20 cm diameter, the observed range of spatial resolutions was 0.
7 − 1.
6 mm compared to 1.
0 − 2.
4 mm at best with a straight line path assumption.
The improvement was strongly enhanced in shorter 200° scans.
Conclusions:Improved spatial resolution was obtained in pCT images with filtered backprojection reconstruction using most likely path estimates of protons.
The improvement in spatial resolution combined with the practicality of FBP algorithms compared to iterative reconstruction algorithms makes this new algorithm a candidate of choice for clinical pCT.
Related Results
GPU-accelerated 3D backprojection of ALOS SAR data from Greenland
GPU-accelerated 3D backprojection of ALOS SAR data from Greenland
The backprojection algorithm for synthetic aperture radar (SAR) has the
ability of focusing raw data and forming an image without requiring
simplifying assumptions for the azimuth-...
List-mode proton CT reconstruction
List-mode proton CT reconstruction
Reconstruction tomographique proton CT en mode liste
La thérapie proton est utilisée dans le cadre du traitement contre le cancer afin de parvenir à une meilleure d...
Backprojection with fourier series expansion and FFT
Backprojection with fourier series expansion and FFT
AbstractThe filtered backprojection (FBP) method has recently been used for almost all the practical CT scanners because of its simple principle and high accuracy in reconstruction...
A filtered backprojection algorithm for cone beam reconstructionusing rotational filtering under helical source trajectory
A filtered backprojection algorithm for cone beam reconstructionusing rotational filtering under helical source trajectory
With the evolution from multi‐detector‐row CT to cone beam (CB) volumetric CT, maintaining reconstruction accuracy becomes more challenging. To combat the severe artifacts caused b...
Variability in CT lung‐nodule volumetry: Effects of dose reduction and reconstruction methods
Variability in CT lung‐nodule volumetry: Effects of dose reduction and reconstruction methods
Purpose:Measuring the size of nodules on chest CT is important for lung cancer staging and measuring therapy response. 3D volumetry has been proposed as a more robust alternative t...
A Graph Based Design Methodology for Compliant Mechanisms (Non Linear Springs) to More Fully Explore and Exploit the Design Domain
A Graph Based Design Methodology for Compliant Mechanisms (Non Linear Springs) to More Fully Explore and Exploit the Design Domain
Abstract
Nonlinear springs are compliant mechanisms that may provide desired force versus displacement relations that give rise to improved energy storage, and impro...
Unraveling the mechanism of proton translocation in the extracellular half-channel of bacteriorhodopsin
Unraveling the mechanism of proton translocation in the extracellular half-channel of bacteriorhodopsin
AbstractBacteriorhodopsin, a light activated protein that creates a proton gradient in halobacteria, has long served as a simple model of proton pumps. Within bacteriorhodopsin, se...
Ground state quantum vortex proton model
Ground state quantum vortex proton model
Abstract
A novel photon-based proton model is developed. A proton’s ground state is assumed to be coherent to the degree that all of its mass-energy precipitates into a sin...

