Javascript must be enabled to continue!
Variability in CT lung‐nodule volumetry: Effects of dose reduction and reconstruction methods
View through CrossRef
Purpose:Measuring the size of nodules on chest CT is important for lung cancer staging and measuring therapy response. 3D volumetry has been proposed as a more robust alternative to 1D and 2D sizing methods. There have also been substantial advances in methods to reduce radiation dose in CT. The purpose of this work was to investigate the effect of dose reduction and reconstruction methods on variability in 3D lung‐nodule volumetry.Methods:Reduced‐dose CT scans were simulated by applying a noise‐addition tool to the raw (sinogram) data from clinically indicated patient scans acquired on a multidetector‐row CT scanner (Definition Flash, Siemens Healthcare). Scans were simulated at 25%, 10%, and 3% of the dose of their clinical protocol (CTDIvol of 20.9 mGy), corresponding to CTDIvol values of 5.2, 2.1, and 0.6 mGy. Simulated reduced‐dose data were reconstructed with both conventional filtered backprojection (B45 kernel) and iterative reconstruction methods (SAFIRE: I44 strength 3 and I50 strength 3). Three lab technologist readers contoured “measurable” nodules in 33 patients under each of the different acquisition/reconstruction conditions in a blinded study design. Of the 33 measurable nodules, 17 were used to estimate repeatability with their clinical reference protocol, as well as interdose and inter‐reconstruction‐method reproducibilities. The authors compared the resulting distributions of proportional differences across dose and reconstruction methods by analyzing their means, standard deviations (SDs), and t‐test and F‐test results.Results:The clinical‐dose repeatability experiment yielded a mean proportional difference of 1.1% and SD of 5.5%. The interdose reproducibility experiments gave mean differences ranging from −5.6% to −1.7% and SDs ranging from 6.3% to 9.9%. The inter‐reconstruction‐method reproducibility experiments gave mean differences of 2.0% (I44 strength 3) and −0.3% (I50 strength 3), and SDs were identical at 7.3%. For the subset of repeatability cases, inter‐reconstruction‐method mean/SD pairs were (1.4%, 6.3%) and (−0.7%, 7.2%) for I44 strength 3 and I50 strength 3, respectively. Analysis of representative nodules confirmed that reader variability appeared unaffected by dose or reconstruction method.Conclusions:Lung‐nodule volumetry was extremely robust to the radiation‐dose level, down to the minimum scanner‐supported dose settings. In addition, volumetry was robust to the reconstruction methods used in this study, which included both conventional filtered backprojection and iterative methods.
Title: Variability in CT lung‐nodule volumetry: Effects of dose reduction and reconstruction methods
Description:
Purpose:Measuring the size of nodules on chest CT is important for lung cancer staging and measuring therapy response.
3D volumetry has been proposed as a more robust alternative to 1D and 2D sizing methods.
There have also been substantial advances in methods to reduce radiation dose in CT.
The purpose of this work was to investigate the effect of dose reduction and reconstruction methods on variability in 3D lung‐nodule volumetry.
Methods:Reduced‐dose CT scans were simulated by applying a noise‐addition tool to the raw (sinogram) data from clinically indicated patient scans acquired on a multidetector‐row CT scanner (Definition Flash, Siemens Healthcare).
Scans were simulated at 25%, 10%, and 3% of the dose of their clinical protocol (CTDIvol of 20.
9 mGy), corresponding to CTDIvol values of 5.
2, 2.
1, and 0.
6 mGy.
Simulated reduced‐dose data were reconstructed with both conventional filtered backprojection (B45 kernel) and iterative reconstruction methods (SAFIRE: I44 strength 3 and I50 strength 3).
Three lab technologist readers contoured “measurable” nodules in 33 patients under each of the different acquisition/reconstruction conditions in a blinded study design.
Of the 33 measurable nodules, 17 were used to estimate repeatability with their clinical reference protocol, as well as interdose and inter‐reconstruction‐method reproducibilities.
The authors compared the resulting distributions of proportional differences across dose and reconstruction methods by analyzing their means, standard deviations (SDs), and t‐test and F‐test results.
Results:The clinical‐dose repeatability experiment yielded a mean proportional difference of 1.
1% and SD of 5.
5%.
The interdose reproducibility experiments gave mean differences ranging from −5.
6% to −1.
7% and SDs ranging from 6.
3% to 9.
9%.
The inter‐reconstruction‐method reproducibility experiments gave mean differences of 2.
0% (I44 strength 3) and −0.
3% (I50 strength 3), and SDs were identical at 7.
3%.
For the subset of repeatability cases, inter‐reconstruction‐method mean/SD pairs were (1.
4%, 6.
3%) and (−0.
7%, 7.
2%) for I44 strength 3 and I50 strength 3, respectively.
Analysis of representative nodules confirmed that reader variability appeared unaffected by dose or reconstruction method.
Conclusions:Lung‐nodule volumetry was extremely robust to the radiation‐dose level, down to the minimum scanner‐supported dose settings.
In addition, volumetry was robust to the reconstruction methods used in this study, which included both conventional filtered backprojection and iterative methods.
Related Results
Primary Thyroid Non-Hodgkin B-Cell Lymphoma: A Case Series
Primary Thyroid Non-Hodgkin B-Cell Lymphoma: A Case Series
Abstract
Introduction
Non-Hodgkin lymphoma (NHL) of the thyroid, a rare malignancy linked to autoimmune disorders, is poorly understood in terms of its pathogenesis and treatment o...
Complex Collision Tumors: A Systematic Review
Complex Collision Tumors: A Systematic Review
Abstract
Introduction: A collision tumor consists of two distinct neoplastic components located within the same organ, separated by stromal tissue, without histological intermixing...
Influence of seabed heterogeneity on benthic megafaunal community patterns in abyssal nodule fields
Influence of seabed heterogeneity on benthic megafaunal community patterns in abyssal nodule fields
Polymetallic nodule fields, at 3000–6000 m depth, harbour some of the most diverse seabed communities in the abyss. In these habitats, nodules are keystone structures for many sess...
The impact of cardiopulmonary hemodynamic factors in volumetry for pulmonary nodule management
The impact of cardiopulmonary hemodynamic factors in volumetry for pulmonary nodule management
Abstract
Background
The acceptance of coronary CT angiogram (CCTA) scans in the management of stable angina has led to an exponential increase in st...
The impact of lung parenchyma attenuation on nodule volumetry in lung cancer screening
The impact of lung parenchyma attenuation on nodule volumetry in lung cancer screening
Abstract
Background
Recent recommendations for lung nodule management include volumetric analysis using tools that present intrinsic measurement var...
Variability of pulmonary nodule volumetry on coronary CT angiograms
Variability of pulmonary nodule volumetry on coronary CT angiograms
This study aims to investigate the variability of pulmonary nodule (PN) volumetry on multiphase coronary CT angiograms (CCTA).
Two radiologists reviewed 5973 CCTA scans i...
Lung Nodule Malignancy Classification with Associated Pulmonary Fibrosis using 3D Attention-gated Convolutional Network with CT scans
Lung Nodule Malignancy Classification with Associated Pulmonary Fibrosis using 3D Attention-gated Convolutional Network with CT scans
AbstractBackground Chest Computed tomography (CT) scans detect lung nodules and assess pulmonary fibrosis. While pulmonary fibrosis indicates increased lung cancer risk, current cl...
Time to Start Up: CT-Basted Radiomics in Children’s Lung Diseases
Time to Start Up: CT-Basted Radiomics in Children’s Lung Diseases
Radiomics is a new interdisciplinary field and a fusion product consisting by large data technology and medical image to aid diagnosis. Radiomics can gather information from differ...

