Pulse selection algorithm for NM64 neutron detector

View through CrossRef
Abstract We propose an algorithm to sepearate pile-up pulses in neutron detectors by utilizing a standard pulse. For this method to be effective, the data must consist mostly of isolated pulses. First, we define a reference pulse by averaging a sample of clearly isolated pulses. Then, for an arbitrary signal, we calculate a shape deviation by summing up the squared residuals between it and the reference pulse. The pulse with the greatest shape deviation is removed from the process. We then recalculate the reference pulse and repeat until the remaining pulses have shape deviation within a threshold. These remaining pulses exhibit a very good linear trend between area and height, allowing us to screen those suspected as pile-ups. A pulse much higher than the final reference pulse, despite being in the area-height-trend and having low shape deviation, is considered a pile-up of two identical pulses. The final reference pulse is fitted to a function defined by two pieces of Gaussian-multiplied polynomial, normalized, and called the standard pulse. We attempted to fit the pile-up pulse with one standard pulse to separate pile-up pulses. If the sum of squared normalized residuals is higher than some threshold, we add one more pulse, try fitting again, and repeat up to three pulses. We apply this algorithm to the pulses collected from one counter at the Princess Sirindhorn Neutron Monitor station at the summit of Doi Inthanon Mountain, Chiang Mai, Thailand, measured by an oscilloscope. The algorithm correctly separates obvious pile-up cases, allowing to record individual pulse timing with improved accuracy. However, we found small pulses, usually belong to gamma rays, that blend with neutron pulse and pass 100 mV output filtration. After removing those under 100 mV, the pulse area distribution of the separated pile-up is consistent with that of single pulses except at very small pulse sizes.
Title: Pulse selection algorithm for NM64 neutron detector
Description:
Abstract We propose an algorithm to sepearate pile-up pulses in neutron detectors by utilizing a standard pulse.
For this method to be effective, the data must consist mostly of isolated pulses.
First, we define a reference pulse by averaging a sample of clearly isolated pulses.
Then, for an arbitrary signal, we calculate a shape deviation by summing up the squared residuals between it and the reference pulse.
The pulse with the greatest shape deviation is removed from the process.
We then recalculate the reference pulse and repeat until the remaining pulses have shape deviation within a threshold.
These remaining pulses exhibit a very good linear trend between area and height, allowing us to screen those suspected as pile-ups.
A pulse much higher than the final reference pulse, despite being in the area-height-trend and having low shape deviation, is considered a pile-up of two identical pulses.
The final reference pulse is fitted to a function defined by two pieces of Gaussian-multiplied polynomial, normalized, and called the standard pulse.
We attempted to fit the pile-up pulse with one standard pulse to separate pile-up pulses.
If the sum of squared normalized residuals is higher than some threshold, we add one more pulse, try fitting again, and repeat up to three pulses.
We apply this algorithm to the pulses collected from one counter at the Princess Sirindhorn Neutron Monitor station at the summit of Doi Inthanon Mountain, Chiang Mai, Thailand, measured by an oscilloscope.
The algorithm correctly separates obvious pile-up cases, allowing to record individual pulse timing with improved accuracy.
However, we found small pulses, usually belong to gamma rays, that blend with neutron pulse and pass 100 mV output filtration.
After removing those under 100 mV, the pulse area distribution of the separated pile-up is consistent with that of single pulses except at very small pulse sizes.

Related Results

A Method for Determining the Porosity of Pulsed Neutron by Combining Gamma Energy and Time Spectrum
A Method for Determining the Porosity of Pulsed Neutron by Combining Gamma Energy and Time Spectrum
Pulsed-neutron gamma energy spectroscopy and neutron lifetime measurement systems enable the evaluation of the elemental content, saturation. And recent studies have demonstrated t...
A New Method of Porosity Determination by D-T Neutron Generator and Dual CLYC Detector
A New Method of Porosity Determination by D-T Neutron Generator and Dual CLYC Detector
Porosity is one of the essential parameters in conventional oil and gas reservoir evaluation, as well as plays an important role in the calculation of formation saturation and rese...
Study of coded source neutron imaging based on a compact accelerator
Study of coded source neutron imaging based on a compact accelerator
Compact accelerator based neutron source has lower cost and better flexibility than nuclear reactor. Neutron imaging using such a neutron source has attracted more and more attenti...
Determination of Coal Ash Content by Neutron-Neutron Logging
Determination of Coal Ash Content by Neutron-Neutron Logging
Abstract The research is aimed at assessing the possibility of studying the ash content of coal seams using neutron-neutron logging in coal exploration wells drilled...
A Novel Gamma-Thermal Neutron Evaluating Gas Saturation Method Using Pulsed Neutron Logging Tool With Dual-CLYC
A Novel Gamma-Thermal Neutron Evaluating Gas Saturation Method Using Pulsed Neutron Logging Tool With Dual-CLYC
In our previous research which has published in 62th SPWLA symposium, a numerical simulation method was proposed which about the double particle detector CLYC (Cs2LiYCl6:CE) to get...
Neutron holography simulation based on different sample rotations
Neutron holography simulation based on different sample rotations
Neutron holography is a new imaging technique based on the recording of the interference pattern of two coherent waves emitted by the same source, which allows observing the spatia...
AN ACCURATELY DETERMINING POROSITY METHOD FROM PULSED-NEUTRON ELEMENT LOGGING IN UNCONVENTIONAL RESERVOIRS
AN ACCURATELY DETERMINING POROSITY METHOD FROM PULSED-NEUTRON ELEMENT LOGGING IN UNCONVENTIONAL RESERVOIRS
Unconventional reservoirs have low porosity and complex mineral composition containing quartz, feldspar, calcite, dolomite, pyrite and kerogen, which may seriously reduce the accur...

Back to Top