Javascript must be enabled to continue!
Neutron holography simulation based on different sample rotations
View through CrossRef
Neutron holography is a new imaging technique based on the recording of the interference pattern of two coherent waves emitted by the same source, which allows observing the spatial order of microscopic objects like molecules or atoms in crystal sample. Two approaches can be used in neutron holography measurements. One is called inside-source holography, in which both the reference wave and object wave come from embedded atoms in the sample and propagate toward the detector outside the sample. The second approach called inside-detector holography is the inverse method of inside-source holography, in this case the reference wave is the initial neutron beam coming from a distant source outside the sample, while the atoms embedded in the sample act as detectors. In an ideal inside-source holography experiment, the sample should be fixed and the detector moves on a sphere, which is not practical because the detector system is usually heavy and far from the sample. In order to minimize the operation space, the detector always moves on a circle around sample or is located at a fixed position, while the sample rotates in an appropriate way to imitate the motion of the detector in a sphere. However, the orientation of the sample relative to the incident neutron beam is changed during sample rotation, and part of the inverse hologram is recorded together with the inside-detector hologram, which can cause distortion in the holographic reconstruction. In this paper, we simulate neutron holograms and reconstructions based on three different sample/detector rotations. In the first case, the detector moves on a circle, while the sample rotates about an axis perpendicular to the detector moving surface. In the second case, the detector is fixed, while the sample rotates around two perpendicular axes, the θ axis rotating the sample through πradians is perpendicular to the incident beam-detector plane, while the θ axis rotating the sample through 2πradians moves on a circle parallel to the incident beam-detector plane, this rotation can be carried out on a 3-axis spectrometry. In the third case, the detector is also fixed and the sample rotates around two perpendicular axes, but the θ axis is parallel to the sample-detector direction, while the θ axis moves on a circle perpendicular to the incident beam-detector plane, this rotation can be carried out on a 4-cycle spectrometry. The distortions and corresponding correcting methods of three kinds of rotations are discussed. The result shows that most distortions can be corrected by using special measurement or reconstruction techniques. Furthermore, pure sample rotation based on 3-axis spectrometer can achieve the best reconstruction result, so this rotation approach is preferred if conditions permit.
Title: Neutron holography simulation based on different sample rotations
Description:
Neutron holography is a new imaging technique based on the recording of the interference pattern of two coherent waves emitted by the same source, which allows observing the spatial order of microscopic objects like molecules or atoms in crystal sample.
Two approaches can be used in neutron holography measurements.
One is called inside-source holography, in which both the reference wave and object wave come from embedded atoms in the sample and propagate toward the detector outside the sample.
The second approach called inside-detector holography is the inverse method of inside-source holography, in this case the reference wave is the initial neutron beam coming from a distant source outside the sample, while the atoms embedded in the sample act as detectors.
In an ideal inside-source holography experiment, the sample should be fixed and the detector moves on a sphere, which is not practical because the detector system is usually heavy and far from the sample.
In order to minimize the operation space, the detector always moves on a circle around sample or is located at a fixed position, while the sample rotates in an appropriate way to imitate the motion of the detector in a sphere.
However, the orientation of the sample relative to the incident neutron beam is changed during sample rotation, and part of the inverse hologram is recorded together with the inside-detector hologram, which can cause distortion in the holographic reconstruction.
In this paper, we simulate neutron holograms and reconstructions based on three different sample/detector rotations.
In the first case, the detector moves on a circle, while the sample rotates about an axis perpendicular to the detector moving surface.
In the second case, the detector is fixed, while the sample rotates around two perpendicular axes, the θ axis rotating the sample through πradians is perpendicular to the incident beam-detector plane, while the θ axis rotating the sample through 2πradians moves on a circle parallel to the incident beam-detector plane, this rotation can be carried out on a 3-axis spectrometry.
In the third case, the detector is also fixed and the sample rotates around two perpendicular axes, but the θ axis is parallel to the sample-detector direction, while the θ axis moves on a circle perpendicular to the incident beam-detector plane, this rotation can be carried out on a 4-cycle spectrometry.
The distortions and corresponding correcting methods of three kinds of rotations are discussed.
The result shows that most distortions can be corrected by using special measurement or reconstruction techniques.
Furthermore, pure sample rotation based on 3-axis spectrometer can achieve the best reconstruction result, so this rotation approach is preferred if conditions permit.
Related Results
Comparative study of the effect of neutrons emitted from neutron source
241
Am-Be and curcumin on MCF-7 breast cancer cells in 3D culture medium
Comparative study of the effect of neutrons emitted from neutron source
241
Am-Be and curcumin on MCF-7 breast cancer cells in 3D culture medium
Abstract
Introduction
Cancer is one of the major medical problems threatening human health. Breast cancer ...
A Method for Determining the Porosity of Pulsed Neutron by Combining Gamma Energy and Time Spectrum
A Method for Determining the Porosity of Pulsed Neutron by Combining Gamma Energy and Time Spectrum
Pulsed-neutron gamma energy spectroscopy and neutron lifetime measurement systems enable the evaluation of the elemental content, saturation. And recent studies have demonstrated t...
Study of coded source neutron imaging based on a compact accelerator
Study of coded source neutron imaging based on a compact accelerator
Compact accelerator based neutron source has lower cost and better flexibility than nuclear reactor. Neutron imaging using such a neutron source has attracted more and more attenti...
Determination of Coal Ash Content by Neutron-Neutron Logging
Determination of Coal Ash Content by Neutron-Neutron Logging
Abstract
The research is aimed at assessing the possibility of studying the ash content of coal seams using neutron-neutron logging in coal exploration wells drilled...
A New Method of Porosity Determination by D-T Neutron Generator and Dual CLYC Detector
A New Method of Porosity Determination by D-T Neutron Generator and Dual CLYC Detector
Porosity is one of the essential parameters in conventional oil and gas reservoir evaluation, as well as plays an important role in the calculation of formation saturation and rese...
A Novel Gamma-Thermal Neutron Evaluating Gas Saturation Method Using Pulsed Neutron Logging Tool With Dual-CLYC
A Novel Gamma-Thermal Neutron Evaluating Gas Saturation Method Using Pulsed Neutron Logging Tool With Dual-CLYC
In our previous research which has published in 62th SPWLA symposium, a numerical simulation method was proposed which about the double particle detector CLYC (Cs2LiYCl6:CE) to get...
Neutron and Photon Dose Rates in a D-T Neutron Generator Facility: MCNP Simulations and Experiments
Neutron and Photon Dose Rates in a D-T Neutron Generator Facility: MCNP Simulations and Experiments
Abstract
The deuterium-tritium neutron generator is a common neutron source for fast neutron activation analysis. The 14.1 MeV neutrons emitted from a deuterium-tritium n...
AN ACCURATELY DETERMINING POROSITY METHOD FROM PULSED-NEUTRON ELEMENT LOGGING IN UNCONVENTIONAL RESERVOIRS
AN ACCURATELY DETERMINING POROSITY METHOD FROM PULSED-NEUTRON ELEMENT LOGGING IN UNCONVENTIONAL RESERVOIRS
Unconventional reservoirs have low porosity and complex mineral composition containing quartz, feldspar, calcite, dolomite, pyrite and kerogen, which may seriously reduce the accur...

