Javascript must be enabled to continue!
Performance variability of the Hydroacoustic and Infrasound IMS stations
View through CrossRef
Seismic, hydroacoustic, infrasound, and radionuclide are the four complementary monitoring technologies of the Comprehensive Nuclear-Test-Ban Treaty Organization (CTBTO). The International Monitoring System (IMS) of the CTBTO consists of, when complete, 50 primary and 120 auxiliary seismic stations, 11 hydroacoustic stations, 60 infrasound stations, 80 radionuclide stations and 16 radionuclide laboratories. Hydroacoustic and Infrasound stations of IMS are designed to detect events of any kind in and underwater, and in the atmosphere respectively. Hydroacoustic stations have been in operation since 1999; 11 stations, of which 6 hydrophones and 5 T-phase, have been sending data since the completion of the network in 2016. Infrasound data was introduced to routine data analysis in 2010 after improvements in automatic processing to reduce the number of false detections. Currently, 54 (out of 60) infrasound stations are being processed.Both hydroacoustic and infrasound technologies have had significant contributions to detecting and to improving event location at the International Data Centre (IDC). This presentation assesses the data quality and performance of the hydroacoustic and infrasound stations in the data analysis aspect. We focus on signal and event detection rate and in turn the contribution of the data from hydroacoustic and infrasound stations to the data analysis. We show how the station performance changes temporally and discuss the results.
Title: Performance variability of the Hydroacoustic and Infrasound IMS stations
Description:
Seismic, hydroacoustic, infrasound, and radionuclide are the four complementary monitoring technologies of the Comprehensive Nuclear-Test-Ban Treaty Organization (CTBTO).
The International Monitoring System (IMS) of the CTBTO consists of, when complete, 50 primary and 120 auxiliary seismic stations, 11 hydroacoustic stations, 60 infrasound stations, 80 radionuclide stations and 16 radionuclide laboratories.
Hydroacoustic and Infrasound stations of IMS are designed to detect events of any kind in and underwater, and in the atmosphere respectively.
Hydroacoustic stations have been in operation since 1999; 11 stations, of which 6 hydrophones and 5 T-phase, have been sending data since the completion of the network in 2016.
Infrasound data was introduced to routine data analysis in 2010 after improvements in automatic processing to reduce the number of false detections.
Currently, 54 (out of 60) infrasound stations are being processed.
Both hydroacoustic and infrasound technologies have had significant contributions to detecting and to improving event location at the International Data Centre (IDC).
This presentation assesses the data quality and performance of the hydroacoustic and infrasound stations in the data analysis aspect.
We focus on signal and event detection rate and in turn the contribution of the data from hydroacoustic and infrasound stations to the data analysis.
We show how the station performance changes temporally and discuss the results.
Related Results
Earthquakes Detectability of KUT Infrasound Sensor Network During 2019
Earthquakes Detectability of KUT Infrasound Sensor Network During 2019
Infrasound waves can be defined as the sound waves with frequency range
from 0.003 to 20 Hz. Kochi University of Technology (KUT) Infrasound
Sensor Network contains 30 infrasound s...
Infrasound and seismoacoustic signatures of the September 28
th
2018 Sulawesi super shear earthquake
Infrasound and seismoacoustic signatures of the September 28
th
2018 Sulawesi super shear earthquake
Abstract. A magnitude 7.5 earthquake occurred on September 28th 2018 at 10:02:43 UTC near the city of Palu on the Indonesian island of Sulawesi. It was a shallow, strike-slip earth...
New constrains on infrasound source mechanisms within debris-flows
New constrains on infrasound source mechanisms within debris-flows
<p>Debris flows are episodic gravitational currents, consisting of mixtures of water and debris in varying proportions occurring in steep mountain catchments, with vo...
Noise Study Examples for Infrasound Stations
Noise Study Examples for Infrasound Stations
Recent developments of infrasound background noise models (Marty et al, 2021) and progress in the design of digitizers and microbarometers allow the implementation of accurate infr...
 Promoting the Peaceful Use of IMS Data for Climate Research and Climate Change Monitoring             
 Promoting the Peaceful Use of IMS Data for Climate Research and Climate Change Monitoring             
The CTBTO receives, collects, processes, analyzes, reports, and archives data from IMS facilities and makes it available to authorized users. Automatic processing methods and inter...
GW24-e3869 Cardiac Peroxisome Proliferator-Activated Receptor-y Expression is Modulated by Oxidative Stress in Acutely Infrasound-Exposed Rats
GW24-e3869 Cardiac Peroxisome Proliferator-Activated Receptor-y Expression is Modulated by Oxidative Stress in Acutely Infrasound-Exposed Rats
Objectives
Rats were exposed to infrasound for several weeks, and adverse effects on the cardiovascular system were demonstrated using morphology, histopathology,...
INTELLIGENT MONITORING SYSTEMS IN MANUFACTURING: CURRENT STATE AND FUTURE PERSPECTIVES
INTELLIGENT MONITORING SYSTEMS IN MANUFACTURING: CURRENT STATE AND FUTURE PERSPECTIVES
Intelligent Monitoring Systems (IMS) have emerged as indispensable tools in modern manufacturing, offering real-time insights into production processes, equipment performance, and ...
Infrasound from lightning measured in northern Romania
Infrasound from lightning measured in northern Romania
During thunderstorms in northern Romania, numerous infrasonic signals are emitted due to the process of lightning and thunder. Association between infrasound detections into 0.5 to...

