Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Internal Quality Control in Medical Laboratories: Westgard and the Others

View through CrossRef
This review recalls some ISO 15189:2022 requirements for the management of examination results and emerging alternatives to internal quality control (IQC) in relation to Italian Society of Clinical Pathology and Laboratory Medicine (SIPMeL) Recommendation Q19. We observed phenomena of contrasting “metrological”, or rather “tracealogic”, and “statistical” approaches. SIPMeL Recommendation Q19 enhances IQC with a moving average based on ISO 15189, which enables the use of the moving average of patient sample results (MA). In the veterinary field, the procedure of QC with repeat testing on patient samples (RPT-QC) has met with some success. The “Bayesian approach” of IQC makes use of the distinction between a priori probability, evidential probability (data) and a posteriori probability (IQC rules). SIPMeL Recommendation Q19 strictly adheres to the ISO 15189:2022 document. SIPMeL Q19 calls for abandoning the 1–2 s rule, using appropriate computer tools, not only control charts, and trying to reduce false positives to very low frequencies. Alternatives to IQC using patient results and the Bayesian approach are compatible with ISO 15189 and SIPMeL Q19. In contrast, the alternative using material designed for traceability with assigned values, is not compatible with the ISO standard.
Title: Internal Quality Control in Medical Laboratories: Westgard and the Others
Description:
This review recalls some ISO 15189:2022 requirements for the management of examination results and emerging alternatives to internal quality control (IQC) in relation to Italian Society of Clinical Pathology and Laboratory Medicine (SIPMeL) Recommendation Q19.
We observed phenomena of contrasting “metrological”, or rather “tracealogic”, and “statistical” approaches.
SIPMeL Recommendation Q19 enhances IQC with a moving average based on ISO 15189, which enables the use of the moving average of patient sample results (MA).
In the veterinary field, the procedure of QC with repeat testing on patient samples (RPT-QC) has met with some success.
The “Bayesian approach” of IQC makes use of the distinction between a priori probability, evidential probability (data) and a posteriori probability (IQC rules).
SIPMeL Recommendation Q19 strictly adheres to the ISO 15189:2022 document.
SIPMeL Q19 calls for abandoning the 1–2 s rule, using appropriate computer tools, not only control charts, and trying to reduce false positives to very low frequencies.
Alternatives to IQC using patient results and the Bayesian approach are compatible with ISO 15189 and SIPMeL Q19.
In contrast, the alternative using material designed for traceability with assigned values, is not compatible with the ISO standard.

Related Results

Modern approach to automation of internal control of quality and safety of medical care
Modern approach to automation of internal control of quality and safety of medical care
Introduction. Heads of medical organizations operating under the Moscow Healthcare Department are the ones who take care of internal control of quality and safety of medical care [...
Social Media Use in Neurology: An Analysis of Alzheimer's Information on TikTok with Emphasis on Role of Healthcare Professionals
Social Media Use in Neurology: An Analysis of Alzheimer's Information on TikTok with Emphasis on Role of Healthcare Professionals
Abstract Introduction Alzheimer's disease (AD) is the most common neurodegenerative cause of dementia. Social media has become a major source of information for patients and famili...
Nonlinear optimal control for robotic exoskeletons with electropneumatic actuators
Nonlinear optimal control for robotic exoskeletons with electropneumatic actuators
Purpose To provide high torques needed to move a robot’s links, electric actuators are followed by a transmission system with a high transmission rate. For instance, gear ratios of...
L26/P-428 Are ART laboratories ready for sustainability? Lessons from a French national survey
L26/P-428 Are ART laboratories ready for sustainability? Lessons from a French national survey
Abstract Study question What is the current state of eco-responsible initiatives in ART laboratories? Results from a nati...
Analisis Pemantapan Mutu Internal Pada Pemeriksaan Trombosit Dan Leukosit Menggunakan Metode Sigma Metric Di Puskesmas X
Analisis Pemantapan Mutu Internal Pada Pemeriksaan Trombosit Dan Leukosit Menggunakan Metode Sigma Metric Di Puskesmas X
Pemantapan mutu internal (PMI) di laboratorium krusial dilakukan untuk pengawasan dan pencegahan kesalahan hasil pemeriksaan, salah satu PMI dilakukan pada pemeriksaan trombosit da...

Back to Top