Collaborative study for the evaluation of enzyme-linked immunosorbent assays used to measure human antibodies to Bordetella pertussis antigens
View through CrossRef
Acellular pertussis vaccines are being evaluated in multiple clinical studies, and human immunogenicity data will likely be pivotal in the appraisal of vaccine responses between populations and the responses to different vaccine combinations. Antibody response to pertussis antigens is also used in the diagnosis of pertussis. An international study was designed to assess the comparability of data generated in different laboratories by enzyme-linked immunosorbent assays (ELISAs). Thirty-three participating laboratories were asked to quantitate specific antibody to pertussis toxin (PT), filamentous hemagglutinin (FHA), pertactin (PRN), or fimbrial proteins (FIM) in 21 samples. Samples were to be assayed in triplicate in five independent assays by each ELISA routinely performed in the laboratory to assess intra-assay, interassay, and population variability. The mean sample values were used to compare quantitative results among the laboratories. Thirteen of the 32 laboratories which submitted evaluable data for an assay to measure antibodies to PT, 12 of 30 laboratories with assays for FHA, 10 of 17 laboratories with assays for PRN, and 6 of 13 laboratories with assays for FIM maintained a coefficient of variation below 20% for 75% of the samples tested. Assays that measure antibodies to FIM appear to be less precise than the other assays. Precision varied among laboratories that used similar methods. The relative values of intra- and interassay variabilities were not consistent for a given assay within a laboratory, indicating that the sources of these variability components may be unrelated. Precision and agreement appeared less reliable for samples with low antibody levels. Ranking and regression analyses suggest that some laboratories generated comparable quantitative results, although direct comparison or combination of results from different laboratories remains difficult to support. Calibration to the U.S. Reference Pertussis Antisera appears to have been successful at standardizing the results in some laboratories. Statistical analyses are affected by assay precision and are not necessarily reliable sole predictors of biologically relevant differences in quantitative results. If results from different laboratories must be compared, appropriate studies of precision and quantitative agreement should be conducted to support the specific comparisons.
American Society for Microbiology
Title: Collaborative study for the evaluation of enzyme-linked immunosorbent assays used to measure human antibodies to Bordetella pertussis antigens
Description:
Acellular pertussis vaccines are being evaluated in multiple clinical studies, and human immunogenicity data will likely be pivotal in the appraisal of vaccine responses between populations and the responses to different vaccine combinations.
Antibody response to pertussis antigens is also used in the diagnosis of pertussis.
An international study was designed to assess the comparability of data generated in different laboratories by enzyme-linked immunosorbent assays (ELISAs).
Thirty-three participating laboratories were asked to quantitate specific antibody to pertussis toxin (PT), filamentous hemagglutinin (FHA), pertactin (PRN), or fimbrial proteins (FIM) in 21 samples.
Samples were to be assayed in triplicate in five independent assays by each ELISA routinely performed in the laboratory to assess intra-assay, interassay, and population variability.
The mean sample values were used to compare quantitative results among the laboratories.
Thirteen of the 32 laboratories which submitted evaluable data for an assay to measure antibodies to PT, 12 of 30 laboratories with assays for FHA, 10 of 17 laboratories with assays for PRN, and 6 of 13 laboratories with assays for FIM maintained a coefficient of variation below 20% for 75% of the samples tested.
Assays that measure antibodies to FIM appear to be less precise than the other assays.
Precision varied among laboratories that used similar methods.
The relative values of intra- and interassay variabilities were not consistent for a given assay within a laboratory, indicating that the sources of these variability components may be unrelated.
Precision and agreement appeared less reliable for samples with low antibody levels.
Ranking and regression analyses suggest that some laboratories generated comparable quantitative results, although direct comparison or combination of results from different laboratories remains difficult to support.
Calibration to the U.
S.
Reference Pertussis Antisera appears to have been successful at standardizing the results in some laboratories.
Statistical analyses are affected by assay precision and are not necessarily reliable sole predictors of biologically relevant differences in quantitative results.
If results from different laboratories must be compared, appropriate studies of precision and quantitative agreement should be conducted to support the specific comparisons.
Related Results
Optimization of sample preparation for culture-independent sequencing of Bordetella pertussis
Optimization of sample preparation for culture-independent sequencing of Bordetella pertussis
Bordetella pertussis
, the aetiological agent of whooping cough, is re-emerging globally despite widespread vaccination.
...
Pertussis in infants, in their mothers and other contacts in Casablanca, Morocco
Pertussis in infants, in their mothers and other contacts in Casablanca, Morocco
Abstract
Background
In recent decades, there has been a marked increase in the number of reported cases of pertussis around the world, and pertussis continues to be a frequently oc...
Genomic evaluation of
Bordetella spp
. originating from Australia
Genomic evaluation of
Bordetella spp
. originating from Australia
Abstract
Bordetella pertussis
is the primary causative agent of pertussis, a highly infectious respiratory disease associated w...
Pertussis in Poland in 2022
Pertussis in Poland in 2022
IntroductionThe epidemiological situation of pertussis in Poland in 2022 was influenced by the cancellation of the COVID-19 epidemic and the introduction of an epidemic threat. Dec...
Long-term human serum antibody responses after immunization with whole-cell pertussis vaccine in France
Long-term human serum antibody responses after immunization with whole-cell pertussis vaccine in France
Three hundred sixty children were tested for pertussis serology 0.5 to 1.58 months after complete whole-cell pertussis vaccination. An immunoblot assay was used to detect serum ant...
The Hidden Problem of Cross-Reactivity: Challenges in HIV Testing During the COVID-19 Era: A Systematic Review
The Hidden Problem of Cross-Reactivity: Challenges in HIV Testing During the COVID-19 Era: A Systematic Review
Abstract
Introduction
Human immunodeficiency virus (HIV) and Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV2) surface glycoproteins, including shared epitope motifs, sho...
PERTUSSIS INCIDENCE AND THE EFFECT OF REVACCINATION OF PRESCHOOL AND SCHOOL CHILDREN
PERTUSSIS INCIDENCE AND THE EFFECT OF REVACCINATION OF PRESCHOOL AND SCHOOL CHILDREN
The review is devoted to the analysis of pertussis incidence of children in the age group of 5–7, as well as strategies of DTP immunization with the help of the drugs in foreign co...
Rising cases of pertussis in Albania: should we review our vaccination strategies?
Rising cases of pertussis in Albania: should we review our vaccination strategies?
Since January 2024, in Albania, we have noted an increased number of visits because of Bordetella pertussis affecting all age groups. The increased numbers reflect increased circul...