Operating Room Waste Generated From Corneal and Conjunctival Surgeries

View through CrossRef
Purpose: The purposes of this study were to bring awareness to the surgical waste generated from corneal and conjunctival surgeries and to compare those findings with the waste generated from cataract surgeries. Methods: This was an observational prospective pilot cohort study at a tertiary corneal/anterior segment private practice. All waste related to cataract, cornea, and conjunctival surgical procedures (including anesthesia waste and corneal tissue storage) was weighed. The primary outcome was total waste generated while other outcomes included surgical setting (ambulatory surgical center, hospital, and minor operating room) and comparison of corneal/conjunctival surgeries with cataract surgery. Results: Surgical waste data were collected from 119 surgeries (82 corneal/conjunctival surgeries and 37 cataract surgeries). Hospital surgeries produced more waste than ambulatory surgical center and minor operating room surgeries. Penetrating keratoplasty (2.22 kg, P = 0.483) and Descemet stripping only (2.11 kg, P = 0.326) procedures generated comparable mean waste with cataract surgery (2.07 kg) while endothelial keratoplasties produced more (P < 0.001, 0.002). (Deep) anterior lamellar keratoplasty results depended on the surgical setting. All conjunctival surgeries produced less waste than cataract surgery. Conclusions: In comparison with cataract surgery, keratoplasties overall produced comparable or more waste while conjunctival surgeries produced less waste. The surgical setting and type of anesthesia played a substantial role in the amount of waste generated. Assessing waste production from different ophthalmic surgeries may increase awareness of the negative environmental impact of surgical waste and promote practice or legal changes to improve environmental sustainability.
Title: Operating Room Waste Generated From Corneal and Conjunctival Surgeries
Description:
Purpose: The purposes of this study were to bring awareness to the surgical waste generated from corneal and conjunctival surgeries and to compare those findings with the waste generated from cataract surgeries.
Methods: This was an observational prospective pilot cohort study at a tertiary corneal/anterior segment private practice.
All waste related to cataract, cornea, and conjunctival surgical procedures (including anesthesia waste and corneal tissue storage) was weighed.
The primary outcome was total waste generated while other outcomes included surgical setting (ambulatory surgical center, hospital, and minor operating room) and comparison of corneal/conjunctival surgeries with cataract surgery.
Results: Surgical waste data were collected from 119 surgeries (82 corneal/conjunctival surgeries and 37 cataract surgeries).
Hospital surgeries produced more waste than ambulatory surgical center and minor operating room surgeries.
Penetrating keratoplasty (2.
22 kg, P = 0.
483) and Descemet stripping only (2.
11 kg, P = 0.
326) procedures generated comparable mean waste with cataract surgery (2.
07 kg) while endothelial keratoplasties produced more (P < 0.
001, 0.
002).
(Deep) anterior lamellar keratoplasty results depended on the surgical setting.
All conjunctival surgeries produced less waste than cataract surgery.
Conclusions: In comparison with cataract surgery, keratoplasties overall produced comparable or more waste while conjunctival surgeries produced less waste.
The surgical setting and type of anesthesia played a substantial role in the amount of waste generated.
Assessing waste production from different ophthalmic surgeries may increase awareness of the negative environmental impact of surgical waste and promote practice or legal changes to improve environmental sustainability.

Related Results

Hydrodissection in the Construction of Conjunctival Flaps in Dogs
Hydrodissection in the Construction of Conjunctival Flaps in Dogs
Background: Hydrodissection is a minimally invasive procedure that consists of injecting fluid into an anatomical space to facilitate dissection during surgery. Although this proce...
Water Trash Collector
Water Trash Collector
In today day to day life, approximately 71% of the Earth's surface is covered by Without affecting significant role that technology plays in our modern world, environmental and wat...
Alteration of corneal biomechanical properties in patients with dry eye disease
Alteration of corneal biomechanical properties in patients with dry eye disease
Purpose To evaluate the association between symptoms and signs of dry eye diseases (DED) with corneal biomechanical parameters. Methods This cross-sectional study enrolled 81 par...
Surface modification treatments to enhance the performance of titanium backplate in keratoprosthesis
Surface modification treatments to enhance the performance of titanium backplate in keratoprosthesis
(English) The cornea is the outermost layer of the eye, essential for vision as it provides protection and contributes 80% of the eye’s refractive power. Its transparency and lack ...
Corneal densitometry changes in keratoconus patients after intrastromal corneal ring segments implantation
Corneal densitometry changes in keratoconus patients after intrastromal corneal ring segments implantation
BackgroundKeratoconus (KC) is an ectatic corneal disorder characterized by progressive corneal thinning with myopic astigmatism. Intrastromal corneal ring segments (ICRS) have been...
PENGETAHUAN MAHASISWA TATA BUSANA TENTANG ZERO WASTE PATTERN
PENGETAHUAN MAHASISWA TATA BUSANA TENTANG ZERO WASTE PATTERN
Textile waste is one of the 2nd largest types of waste in the world. The increasing amount of textile waste will have an impact on the environment. There has not been much developm...

Back to Top