Javascript must be enabled to continue!
Pullout strength of monocortical and bicortical screws in meta -physeal and diaphyseal regions of the canine humerus
View through CrossRef
Summary
Objective: Monocortical screws are commonly employed in locking plate fixation, but specific recommendations for their placement are lacking and use of short monocortical screws in metaphyseal bone may be contra indicated. Objectives of this study were to evaluate axial pullout strength of two different lengths of monocortical screws placed in various regions of the canine humerus compared to bicortical screws, and to derive cortical thickness and bone density values for those regions using quantitative computed tomography analysis (QCT).
Methods: The QCT analysis was performed on 36 cadaveric canine humeri for six regions of interest (ROI). A bicortical, short monocortical, or 50% transcortical 3.5 mm screw was implanted in each ROI and axial pullout testing was performed.
Results: Bicortical screws were stronger than monocortical screws in all ROI except the lateral epicondylar crest. Short monocortical metaphyseal screws were weaker than those placed in other regions. The 50% transcortical screws were stronger than the short monocortical screws in the condyle. A linear relationship between screw length and pull-out strength was observed.
Clinical significance: Cortical thickness and bone density measurements were obtained from multiple regions of the canine humerus using QCT. Use of short monocortical screws may contribute to failure of locking plate fixation of humeral fractures, especially when placed in the condyle. When bicortical screw placement is not possible, maximizing monocortical screw length may optimize fixation stability for distal humeral fractures.
Title: Pullout strength of monocortical and bicortical screws in meta -physeal and diaphyseal regions of the canine humerus
Description:
Summary
Objective: Monocortical screws are commonly employed in locking plate fixation, but specific recommendations for their placement are lacking and use of short monocortical screws in metaphyseal bone may be contra indicated.
Objectives of this study were to evaluate axial pullout strength of two different lengths of monocortical screws placed in various regions of the canine humerus compared to bicortical screws, and to derive cortical thickness and bone density values for those regions using quantitative computed tomography analysis (QCT).
Methods: The QCT analysis was performed on 36 cadaveric canine humeri for six regions of interest (ROI).
A bicortical, short monocortical, or 50% transcortical 3.
5 mm screw was implanted in each ROI and axial pullout testing was performed.
Results: Bicortical screws were stronger than monocortical screws in all ROI except the lateral epicondylar crest.
Short monocortical metaphyseal screws were weaker than those placed in other regions.
The 50% transcortical screws were stronger than the short monocortical screws in the condyle.
A linear relationship between screw length and pull-out strength was observed.
Clinical significance: Cortical thickness and bone density measurements were obtained from multiple regions of the canine humerus using QCT.
Use of short monocortical screws may contribute to failure of locking plate fixation of humeral fractures, especially when placed in the condyle.
When bicortical screw placement is not possible, maximizing monocortical screw length may optimize fixation stability for distal humeral fractures.
Related Results
PROXIMAL HUMERUS FRACTURES, ANATOMY, EPIDEMIOLOGY, MECHANISMS OF ACTION, CLASSIFICATION, CLINICAL PRESENTATION, IMAGING PRESENTATION, DIFFERENTIAL DIAGNOSIS, TREATMENT AND COMPLICATIONS
PROXIMAL HUMERUS FRACTURES, ANATOMY, EPIDEMIOLOGY, MECHANISMS OF ACTION, CLASSIFICATION, CLINICAL PRESENTATION, IMAGING PRESENTATION, DIFFERENTIAL DIAGNOSIS, TREATMENT AND COMPLICATIONS
Introduction: Proximal humerus fractures (PHF) make up 5 to 6% of all fractures presented in adults. Approximately 67 to 85% of proximal humerus fractures are managed non-surgicall...
Experimental study on the pullout characteristics of toothed warp knitted geogrid in different sand fillers
Experimental study on the pullout characteristics of toothed warp knitted geogrid in different sand fillers
In order to investigate the pullout characteristics of a toothed geogrid, a commercialized warp-knitted geogrid was combined with rigid angle aluminum to form a qualified toothed g...
Variables Associated With Loss of Fixation of Retrograde Rami Screws in Minimally Displaced Lateral Compression Type 1 Pelvic Ring Injuries
Variables Associated With Loss of Fixation of Retrograde Rami Screws in Minimally Displaced Lateral Compression Type 1 Pelvic Ring Injuries
OBJECTIVES:
To evaluate variables associated with loss of fixation of retrograde rami screws in the treatment of stress-positive minimally displaced lateral compression...
Abstract 1772: A naturally occurring canine model of peripheral T-cell lymphoma, not otherwise specified
Abstract 1772: A naturally occurring canine model of peripheral T-cell lymphoma, not otherwise specified
Abstract
Despite being the most common subtype of human peripheral T-cell lymphoma (PTCL), PTCL-not otherwise specified (PTCL-NOS) remains a poorly understood diagno...
Stiffness Comparisons of SOP Interlocking Plate Configurations in 3D Printed Canine Lumbosacral Vertebrae
Stiffness Comparisons of SOP Interlocking Plate Configurations in 3D Printed Canine Lumbosacral Vertebrae
There are no published biomechanical studies evaluating the effect of stabilization techniques on the stability of the 3D printed models of the canine lumbosacral junction. The p...
Biomechanical analysis of four external fixation pin insertion techniques
Biomechanical analysis of four external fixation pin insertion techniques
Having multiple external fixation pin designs and insertion techniques has led to debate as to which combination creates the stiffest construct. This study sought to biomechanicall...
Spontaneous Resolution of Pediatric Varus Ankle Deformity: A Case Report
Spontaneous Resolution of Pediatric Varus Ankle Deformity: A Case Report
Introduction: Distal tibia fractures are a common cause of physeal injuries that can subsequently cause deformity in pediatric populations. Limited literature exists supporting tre...
Expectant Management of a Posteriorly Displaced Medial Clavicular Physeal Fracture in an Adolescent
Expectant Management of a Posteriorly Displaced Medial Clavicular Physeal Fracture in an Adolescent
Introduction: Sternoclavicular joint (SCJ) disruptions are rare, with posterior dislocations even less common. In pediatric patients, these injuries primarily manifest as medial cl...

