Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Screw Coating as a Solution to Solve Screw Loosening Complications: An In Vitro Study

View through CrossRef
Background: This study aimed to evaluate the influence of a screw coating on the screw preload and removal torque value (RTV) with and without the application of a cyclic load (CL) to make screws with greater untightening resistance to prevent screw loosening. Methods: Ninety complexes composed of implants, abutments, and prosthetic screws were examined and tested under CL oral conditions (n = 45) and non-CL conditions (nCL, n = 45). Each group was divided into three subgroups (n = 15): a control group (CG) without a screw coating, a GapSeal®-coated screw group (GG), and a polytetrafluoroethylene (PTFE) tape-wrapped screw group (PG). All screws were tightened at 30 Ncm, and the preload was recorded. In the nCL group, the screws were untightened to record the RTV. In the CL group, the screws were tightened, subjected to a CL in distillated water at a temperature of 37 °C, and then untightened to record the RTV. Micro-Ct analysis was conducted on two samples from each group before CL. SEM analyses of two samples per subgroup before and after CL were also performed. Results: The preload in the PG was significantly lower under nCL (29.92 Ncm) compared with CG (30.95 Ncm) and GG (31.19 Ncm) and also under a CL (PG: 30.92 Ncm) compared with CG (31.72 Ncm) and GG (31.42 Ncm). The RTVs of the PG were significantly lower under nCL (15.30 Ncm) compared with CG (27.98 Ncm) and GG (28.46 Ncm). Under CL, the RTVs of the PG were significantly higher (31.50 Ncm) compared with CG (26.00 Ncm) and GG (27.44 Ncm). Conclusions: Wrapping the screw with PTFE tape significantly reduced the preload but resulted in a significantly greater RTV under CL conditions in the simulated oral environment, suggesting that this could be a solution to decrease the risk of screw loosening.
Title: Screw Coating as a Solution to Solve Screw Loosening Complications: An In Vitro Study
Description:
Background: This study aimed to evaluate the influence of a screw coating on the screw preload and removal torque value (RTV) with and without the application of a cyclic load (CL) to make screws with greater untightening resistance to prevent screw loosening.
Methods: Ninety complexes composed of implants, abutments, and prosthetic screws were examined and tested under CL oral conditions (n = 45) and non-CL conditions (nCL, n = 45).
Each group was divided into three subgroups (n = 15): a control group (CG) without a screw coating, a GapSeal®-coated screw group (GG), and a polytetrafluoroethylene (PTFE) tape-wrapped screw group (PG).
All screws were tightened at 30 Ncm, and the preload was recorded.
In the nCL group, the screws were untightened to record the RTV.
In the CL group, the screws were tightened, subjected to a CL in distillated water at a temperature of 37 °C, and then untightened to record the RTV.
Micro-Ct analysis was conducted on two samples from each group before CL.
SEM analyses of two samples per subgroup before and after CL were also performed.
Results: The preload in the PG was significantly lower under nCL (29.
92 Ncm) compared with CG (30.
95 Ncm) and GG (31.
19 Ncm) and also under a CL (PG: 30.
92 Ncm) compared with CG (31.
72 Ncm) and GG (31.
42 Ncm).
The RTVs of the PG were significantly lower under nCL (15.
30 Ncm) compared with CG (27.
98 Ncm) and GG (28.
46 Ncm).
Under CL, the RTVs of the PG were significantly higher (31.
50 Ncm) compared with CG (26.
00 Ncm) and GG (27.
44 Ncm).
Conclusions: Wrapping the screw with PTFE tape significantly reduced the preload but resulted in a significantly greater RTV under CL conditions in the simulated oral environment, suggesting that this could be a solution to decrease the risk of screw loosening.

Related Results

Coating Processes of Pharmaceutical Applicability: A Glimpse
Coating Processes of Pharmaceutical Applicability: A Glimpse
Presentation of manuscript is aiming to furnish glimpse on coating processes. Coating is process of snugly covering substrate surface with coating materials (CoM). In due course co...
The Nasser–Gavvala–Shirodkar–Botchu Classification: A Classification System for Loosening of Endoprosthetic Replacements
The Nasser–Gavvala–Shirodkar–Botchu Classification: A Classification System for Loosening of Endoprosthetic Replacements
Objectives: The indications for femoral endoprosthesis replacement (EPR) use in limb reconstruction have broadened over the last decade. Despite its success, loosening remains the ...
Time-dependent behaviour of bone accentuates loosening in the fixation of fractures using bone-screw systems
Time-dependent behaviour of bone accentuates loosening in the fixation of fractures using bone-screw systems
AimsLoosening is a well-known complication in the fixation of fractures using devices such as locking plates or unilateral fixators. It is believed that high strains in the bone at...
Study on Positioning Accuracy of Aerostatic Lead Screw
Study on Positioning Accuracy of Aerostatic Lead Screw
The aerostatic lead screw is a non-contact type lead screw in which the contact surface of a male screw and a female screw is supported by a pressurized air film. It is characteriz...
Bolt Loosening Behavior of Bolted Joints Under Repeated Transverse Loads
Bolt Loosening Behavior of Bolted Joints Under Repeated Transverse Loads
The objective of the paper is to examine bolt loosening behavior in a bolted joint under transverse loading both experimentally and numerically. Bolt loosening tests were carried o...
Design of Elastic Screw Fasteners under Tensile Load
Design of Elastic Screw Fasteners under Tensile Load
This paper presents an equivalent stress approach in the design of screw fasteners under tensile load. Design equations are formulated for sizing and verifying screw fastener selec...
Biomechanical analysis of pedicle screw density in spinal instrumentation for scoliosis treatment: first results
Biomechanical analysis of pedicle screw density in spinal instrumentation for scoliosis treatment: first results
Clinical studies reveal remarkable variation in screw patterns, or screw density in spinal instrumentation. Screw density may have a great impact on blood loss, operative time, rad...

Back to Top