Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Diagnostic accuracy of an oscillometric blood pressure monitor for atrial fibrillation screening

View through CrossRef
Objective Atrial fibrillation is the most common arrhythmia of clinical significance and hypertension is one of its major risk factors. This study aimed to evaluate the diagnostic accuracy of an automated oscillometric blood pressure (BP) monitor with the function of atrial fibrillation detection for atrial fibrillation screening. Materials and methods Patients attending outpatient cardiology clinics were recruited for atrial fibrillation screening by the BP monitor with triplicate BP measurements for atrial fibrillation detection. Furthermore, a single-lead ECG was recorded simultaneously for comparison as the reference standard. The diagnostic test’s evaluation index were analyzed, including sensitivity, specificity, and receiver operator characteristic (ROC) analysis. Results A total of 295 participants were analyzed including 166 males and 129 females, with an average age of 72.5 ± 5.9 years. The sensitivity and specificity for atrial fibrillation detection by the device were 1.000 and 0.904, respectively, with the area under the ROC curve of 0.952 (95% confidence interval: 0.929–0.975, P < 0.001). Furthermore, the device had a Kappa-value of 0.781 (P < 0.001) with the single-lead ECG in detecting atrial fibrillation. Conclusion The automated oscillometric BP monitor (G.LAB MD41A0) with atrial fibrillation detection function has high sensitivity and specificity with good accuracy for atrial fibrillation screening, which could be used as a reliable screening tool for the early detection of atrial fibrillation with potential benefits.
Title: Diagnostic accuracy of an oscillometric blood pressure monitor for atrial fibrillation screening
Description:
Objective Atrial fibrillation is the most common arrhythmia of clinical significance and hypertension is one of its major risk factors.
This study aimed to evaluate the diagnostic accuracy of an automated oscillometric blood pressure (BP) monitor with the function of atrial fibrillation detection for atrial fibrillation screening.
Materials and methods Patients attending outpatient cardiology clinics were recruited for atrial fibrillation screening by the BP monitor with triplicate BP measurements for atrial fibrillation detection.
Furthermore, a single-lead ECG was recorded simultaneously for comparison as the reference standard.
The diagnostic test’s evaluation index were analyzed, including sensitivity, specificity, and receiver operator characteristic (ROC) analysis.
Results A total of 295 participants were analyzed including 166 males and 129 females, with an average age of 72.
5 ± 5.
9 years.
The sensitivity and specificity for atrial fibrillation detection by the device were 1.
000 and 0.
904, respectively, with the area under the ROC curve of 0.
952 (95% confidence interval: 0.
929–0.
975, P < 0.
001).
Furthermore, the device had a Kappa-value of 0.
781 (P < 0.
001) with the single-lead ECG in detecting atrial fibrillation.
Conclusion The automated oscillometric BP monitor (G.
LAB MD41A0) with atrial fibrillation detection function has high sensitivity and specificity with good accuracy for atrial fibrillation screening, which could be used as a reliable screening tool for the early detection of atrial fibrillation with potential benefits.

Related Results

[RETRACTED] Guardian Blood Balance –Feel the difference Guardian Blood Balance makes! v1
[RETRACTED] Guardian Blood Balance –Feel the difference Guardian Blood Balance makes! v1
[RETRACTED]Guardian Blood Balance Reviews (Works Or Hoax) Does Guardian Botanicals Blood Balance AU Really Works? Read Updated Report! Diabetes and Hypertension is such a health p...
Adiponectin and Lone atrial fibrillation
Adiponectin and Lone atrial fibrillation
Objective: Lone atrial fibrillation is an idiopathic arrhythmia seen in younger individuals without any secondary disease. Adiponectin is an endogenous adipocytokine that increases...
RELATIONSHIP BETWEEN ATRIAL FIBRILLATION CARDIOVERSION AND F
RELATIONSHIP BETWEEN ATRIAL FIBRILLATION CARDIOVERSION AND F
Objectives To investigate the relationship between atrial fibrillation cardioversion and f wave in electrocardiogram, providing an ordinary and noninvasive method...
Left atrial strain parameters are able to predict presence of atrial fibrillation
Left atrial strain parameters are able to predict presence of atrial fibrillation
Abstract Background Three-dimensional speckle-tracking echocardiography allows evaluation of left atrial function, left atrial f...
REMODELLING OF CONNEXIN 43 IN ATRIAL MYOCARDIUM OF PATIENTS WITH ATRIAL FIBRILLATION
REMODELLING OF CONNEXIN 43 IN ATRIAL MYOCARDIUM OF PATIENTS WITH ATRIAL FIBRILLATION
Objectives Remodelling of connexins was found accompanying with atrial fibrillation. The aim of the study is to investigate whether it is the remodelling of conne...
Left atrial function assessment by speckle tracking echocardiography in low-risk atrial fibrillation patients
Left atrial function assessment by speckle tracking echocardiography in low-risk atrial fibrillation patients
Objective: To compare the left atrial function utilising speckle tracking echocardiography in patients with low-risk and high-risk non-valvular atrial fibrillation.Methods: The des...

Back to Top