Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Protective Barriers and Radiant Exposure Delivered from Light-curing Units

View through CrossRef
SUMMARY Objective To evaluate the influence of different protective barriers as a function of the photoactivation distances on the radiant exposure of several light-curing units (LCU). The influence of the protective barriers on the degree of conversion of an adhesive resin was also evaluated. Methods Five LCUs were evaluated: Valo Cordless—used in standard mode (Ultradent, South Jordan, USA); Radii-cal—used in continuous mode (SDI, Bayswater, AU); Emitter D—used in continuous mode (Schuster, Santa Maria, BR); Bluephase N—used in high-intensity mode (Ivoclar Vivadent, Schaan, LI); and Rainbow Curing Light—used in continuous mode (Axdent, Guangdong, CN). For each LCU, radiant exposure was measured with a spectrometer (MARC Resin Calibrator) using three different protective barriers (low-density polyethylene, polyvinyl chloride, or Radii-cal barrier sleeves) and five photoactivation distances (0, 2, 5, 10, and 20 mm). The degree of conversion of an adhesive resin (Adper Scotchbond Multi-Purpose, 3M ESPE, St. Paul, USA) was measured through Fourier-transform infrared spectroscopy. The translucency parameter of protective barriers was measured with a spectrophotometer. For all statistical tests, a significance level of α = 0.05 was set. Results For all LCUs tested, radiant exposure was found to be significantly influenced by both protective barriers and curing distance (p≤0.001). In general terms, all the protective barriers significantly decreased the radiant exposure. Radii-cal barrier sleeves were the protective barrier that most decreased the radiant exposure. Irrespective of the protective barrier used, none of the LCU equipment reached the required minimum radiant exposure of 16 J/cm2 at 10 mm of curing distance. The degree of conversion was not effected by either LCU or a protective barrier (p≥0.211). Conclusions Protective barriers and photoactivation distance reduced the radiant exposure emitted by different LCUs.
Title: Protective Barriers and Radiant Exposure Delivered from Light-curing Units
Description:
SUMMARY Objective To evaluate the influence of different protective barriers as a function of the photoactivation distances on the radiant exposure of several light-curing units (LCU).
The influence of the protective barriers on the degree of conversion of an adhesive resin was also evaluated.
Methods Five LCUs were evaluated: Valo Cordless—used in standard mode (Ultradent, South Jordan, USA); Radii-cal—used in continuous mode (SDI, Bayswater, AU); Emitter D—used in continuous mode (Schuster, Santa Maria, BR); Bluephase N—used in high-intensity mode (Ivoclar Vivadent, Schaan, LI); and Rainbow Curing Light—used in continuous mode (Axdent, Guangdong, CN).
For each LCU, radiant exposure was measured with a spectrometer (MARC Resin Calibrator) using three different protective barriers (low-density polyethylene, polyvinyl chloride, or Radii-cal barrier sleeves) and five photoactivation distances (0, 2, 5, 10, and 20 mm).
The degree of conversion of an adhesive resin (Adper Scotchbond Multi-Purpose, 3M ESPE, St.
Paul, USA) was measured through Fourier-transform infrared spectroscopy.
The translucency parameter of protective barriers was measured with a spectrophotometer.
For all statistical tests, a significance level of α = 0.
05 was set.
Results For all LCUs tested, radiant exposure was found to be significantly influenced by both protective barriers and curing distance (p≤0.
001).
In general terms, all the protective barriers significantly decreased the radiant exposure.
Radii-cal barrier sleeves were the protective barrier that most decreased the radiant exposure.
Irrespective of the protective barrier used, none of the LCU equipment reached the required minimum radiant exposure of 16 J/cm2 at 10 mm of curing distance.
The degree of conversion was not effected by either LCU or a protective barrier (p≥0.
211).
Conclusions Protective barriers and photoactivation distance reduced the radiant exposure emitted by different LCUs.

Related Results

Radiant Heat Loss versus Radiant Heat Gain in Premature Neonates under Radiant Warmers
Radiant Heat Loss versus Radiant Heat Gain in Premature Neonates under Radiant Warmers
Premature infants nursed on open radiant warmer beds are exposed to short-wavelength infrared power density distributed evenly over the bed surface. Additionally, infants’ sides ar...
Improving Light‐Curing Instruction in Dental School
Improving Light‐Curing Instruction in Dental School
Delivering an inadequate amount of light to a light‐cured resin will result in a resin that is inadequately cured. This study measured the radiant exposure that students delivered ...
Microstructure and durability characteristics of self-curing concrete
Microstructure and durability characteristics of self-curing concrete
Efficient curing of concrete requires high water demand which is not available in many practical situations. Therefore, the need of self-curing concrete becomes more demanding. In ...
PENGARUH PERAWATAN BETON (CURING) TERHADAP KUAT TEKAN BETON NORMAL
PENGARUH PERAWATAN BETON (CURING) TERHADAP KUAT TEKAN BETON NORMAL
Abstract— Concrete is a mixture consisting of sand, small stones, cement, and water that forms a solid mass. To produce good-quality concrete, concrete work control is needed, and ...
Design and analysis of dual-curing systems
Design and analysis of dual-curing systems
Dual-curing processing is a method to prepare thermoset materials through two polymerization reactions carried out simultaneously or sequentially. In these processes, a firm under...
Experimental Study on Influencing Factors of Mixing Solidification Strength of Marine Soft Soil
Experimental Study on Influencing Factors of Mixing Solidification Strength of Marine Soft Soil
It is a common problem that the soft soil solidified strength by mixing is low. In order to search for the sensitive factors that affect the solidified strength, a certain marine s...
REKAYASA OVEN PORTABEL-HORISONTAL PADA PENGOLAHAN TEMBAKAU VIRGINIA
REKAYASA OVEN PORTABEL-HORISONTAL PADA PENGOLAHAN TEMBAKAU VIRGINIA
<p>Oven portabel-horisontal (4m x 8m x 4m) untuk pengovenan daun tembakau Virginia menjadi krosok fc (flue-cured) telah direkayasa di Balai Penelitian Tanaman Tembakau dan Se...
Plastcementer
Plastcementer
English summary Resin cements 532 – 7. Tooth-coloured indirect restorations are becoming increasingly popular as alternatives to amalga...

Back to Top