Estimation of the Number of Active Sweat Glands Through Discrete Sweat Sensing

View through CrossRef
Sweat is a biomarker-rich fluid with potential for continuous patient monitoring via wearable devices. However, biomarker concentrations vary with the sweat rate per gland, posing a challenge for sweat sensing. To address this, we propose an algorithm to compute both the number of active sweat glands and their individual sweat rates. We developed models of sweat glands and a discrete sweat-sensing device to sense sweat volume. Our algorithm estimates the number of active glands by decomposing the signal into patterns generated by the individual sweat glands, allowing for the calculation of individual sweat rates. We assessed the algorithm’s accuracy using synthetic datasets for varying physiological parameters (sweat rate and number of active sweat glands) and device layouts. The results show that device layout significantly affects accuracy, with error rates below 0.2% for low and medium sweat rates (below 0.2 nL min−1 per gland). However, the method is not suitable for high sweat rates. The suitable sweat rate range can be adapted to different needs through the choice of device. Based on our findings, we provide recommendations for optimal device layouts to improve accuracy in estimating active sweat glands. This is the first study to focus on estimating the sweat rate per gland, which essential for accurate biomarker concentration estimation and advancing sweat sensing towards clinical applications.
Title: Estimation of the Number of Active Sweat Glands Through Discrete Sweat Sensing
Description:
Sweat is a biomarker-rich fluid with potential for continuous patient monitoring via wearable devices.
However, biomarker concentrations vary with the sweat rate per gland, posing a challenge for sweat sensing.
To address this, we propose an algorithm to compute both the number of active sweat glands and their individual sweat rates.
We developed models of sweat glands and a discrete sweat-sensing device to sense sweat volume.
Our algorithm estimates the number of active glands by decomposing the signal into patterns generated by the individual sweat glands, allowing for the calculation of individual sweat rates.
We assessed the algorithm’s accuracy using synthetic datasets for varying physiological parameters (sweat rate and number of active sweat glands) and device layouts.
The results show that device layout significantly affects accuracy, with error rates below 0.
2% for low and medium sweat rates (below 0.
2 nL min−1 per gland).
However, the method is not suitable for high sweat rates.
The suitable sweat rate range can be adapted to different needs through the choice of device.
Based on our findings, we provide recommendations for optimal device layouts to improve accuracy in estimating active sweat glands.
This is the first study to focus on estimating the sweat rate per gland, which essential for accurate biomarker concentration estimation and advancing sweat sensing towards clinical applications.

Related Results

Investigations into the puerperium of Beagle-breed female dogs
Investigations into the puerperium of Beagle-breed female dogs
The present thesis focusses on the study of the puerperium of female dogs, with the general objective to increase available knowledge regarding the puerperium of that species and t...
(Invited) Carbon Nanotube-Based Fabric Sensor for Selective Sodium Detection in Sweat
(Invited) Carbon Nanotube-Based Fabric Sensor for Selective Sodium Detection in Sweat
Despite the recent advancements in sensor detection of biomarkers in sweat, there is no sensor capable of long-term detection in constricted or load-bearing applications where othe...
Wearable Fabric Sensor Using Functionalized MWCNT Nanocomposite Material
Wearable Fabric Sensor Using Functionalized MWCNT Nanocomposite Material
Despite the recent advancements in sensor detection of biomarkers in sweat, there is no sensor capable of long-term detection in constricted or load-bearing applications where othe...
(Invited) Wearable Flexible Microfluidic Biosensor for Sweat Monitoring
(Invited) Wearable Flexible Microfluidic Biosensor for Sweat Monitoring
As we enter the post-pandemic era, our lives have certainly become more convenient than before, due to the advancement and elimination of technologies that became practical or wide...
Wearable sweat sensing for prolonged, semicontinuous, and nonobtrusive health monitoring
Wearable sweat sensing for prolonged, semicontinuous, and nonobtrusive health monitoring
AbstractTogether with the upcoming market for wearable consumer technologies, noninvasive and continuous health monitoring has become a new trend in the healthcare landscape. In re...
Collegiate soccer players consistently underestimate practice sweat losses regardless of practice sweat loss volume
Collegiate soccer players consistently underestimate practice sweat losses regardless of practice sweat loss volume
Soccer play in hot environments can result in major fluid deficit. If competitors are unsure of their sweat losses, accurate fluid intake needs during and between training bouts ca...
Emerging Evidence of IgG4-Related Disease in Pericarditis: A Systematic Review
Emerging Evidence of IgG4-Related Disease in Pericarditis: A Systematic Review
Abstract Introduction Immunoglobulin G4-related disease (IgG4-RD) is a recently identified immune-mediated condition that is debilitating and often overlooked. While IgG4-RD has be...
Strategi Komunikasi Digital Opinion Leader Medical Pocari Sweat Dalam Eksistensinya Di Tengah Pandemi Covid-19
Strategi Komunikasi Digital Opinion Leader Medical Pocari Sweat Dalam Eksistensinya Di Tengah Pandemi Covid-19
Penelitian yang dilakukan pada narasumber oleh pihak PT. Outsuka bertujuan untuk mengetahui lebih dalam tentang Strategi Komunikasi Digital Opinion Leader Medical Pocari Sweat Dala...

Back to Top