Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Spectra of clinical CT scanners using a portable Compton spectrometer

View through CrossRef
Purpose:Spectral information of the output of x‐ray tubes in (dual source) computer tomography (CT) scanners can be used to improve the conversion of CT numbers to proton stopping power and can be used to advantage in CT scanner quality assurance. The purpose of this study is to design, validate, and apply a compact portable Compton spectrometer that was constructed to accurately measure x‐ray spectra of CT scanners.Methods:In the design of the Compton spectrometer, the shielding materials were carefully chosen and positioned to reduce background by x‐ray fluorescence from the materials used. The spectrum of Compton scattered x‐rays alters from the original source spectrum due to various physical processes. Reconstruction of the original x‐ray spectrum from the Compton scattered spectrum is based on Monte Carlo simulations of the processes involved. This reconstruction is validated by comparing directly and indirectly measured spectra of a mobile x‐ray tube. The Compton spectrometer is assessed in a clinical setting by measuring x‐ray spectra at various tube voltages of three different medical CT scanner x‐ray tubes.Results:The directly and indirectly measured spectra are in good agreement (their ratio being 0.99) thereby validating the reconstruction method. The measured spectra of the medical CT scanners are consistent with theoretical spectra and spectra obtained from the x‐ray tube manufacturer.Conclusions:A Compton spectrometer has been successfully designed, constructed, validated, and applied in the measurement of x‐ray spectra of CT scanners. These measurements show that our compact Compton spectrometer can be rapidly set‐up using the alignment lasers of the CT scanner, thereby enabling its use in commissioning, troubleshooting, and, e.g., annual performance check‐ups of CT scanners.
Title: Spectra of clinical CT scanners using a portable Compton spectrometer
Description:
Purpose:Spectral information of the output of x‐ray tubes in (dual source) computer tomography (CT) scanners can be used to improve the conversion of CT numbers to proton stopping power and can be used to advantage in CT scanner quality assurance.
The purpose of this study is to design, validate, and apply a compact portable Compton spectrometer that was constructed to accurately measure x‐ray spectra of CT scanners.
Methods:In the design of the Compton spectrometer, the shielding materials were carefully chosen and positioned to reduce background by x‐ray fluorescence from the materials used.
The spectrum of Compton scattered x‐rays alters from the original source spectrum due to various physical processes.
Reconstruction of the original x‐ray spectrum from the Compton scattered spectrum is based on Monte Carlo simulations of the processes involved.
This reconstruction is validated by comparing directly and indirectly measured spectra of a mobile x‐ray tube.
The Compton spectrometer is assessed in a clinical setting by measuring x‐ray spectra at various tube voltages of three different medical CT scanner x‐ray tubes.
Results:The directly and indirectly measured spectra are in good agreement (their ratio being 0.
99) thereby validating the reconstruction method.
The measured spectra of the medical CT scanners are consistent with theoretical spectra and spectra obtained from the x‐ray tube manufacturer.
Conclusions:A Compton spectrometer has been successfully designed, constructed, validated, and applied in the measurement of x‐ray spectra of CT scanners.
These measurements show that our compact Compton spectrometer can be rapidly set‐up using the alignment lasers of the CT scanner, thereby enabling its use in commissioning, troubleshooting, and, e.
g.
, annual performance check‐ups of CT scanners.

Related Results

NuSTARobservations of heavily obscuredSwift/BAT AGNs: Constraints on the Compton-thick AGNs fraction
NuSTARobservations of heavily obscuredSwift/BAT AGNs: Constraints on the Compton-thick AGNs fraction
The evolution of the accretion history of the Universe has been studied in unprecedented detail owing to recent X-ray surveys performed byChandraandXMM-Newton. A focus on the most ...
ACCURACY AND PRECISION OF SIX DIGITAL SCANNERS IN FULL ARCH MAXILLARY SCANS: AN IN VITRO COMPARATIVE STUDY
ACCURACY AND PRECISION OF SIX DIGITAL SCANNERS IN FULL ARCH MAXILLARY SCANS: AN IN VITRO COMPARATIVE STUDY
The objective of this study is to evaluate the accuracy and precision of full arch maxillary digital scans produced by six digital scanners. Materials and Methods: A standard model...
Study of generalized Radon transforms and applications in Compton scattering tomography
Study of generalized Radon transforms and applications in Compton scattering tomography
Étude de transformées de Radon généralisées et applications en tomographie Compton Depuis l'avènement des premiers appareils imageurs par rayonnement ionisant initi...
Optimized linear wavenumber spectrometer based spectral-domain optical coherence tomography system
Optimized linear wavenumber spectrometer based spectral-domain optical coherence tomography system
In spectraldomain optical coherence tomography the sample is illuminated by a broadband light source, and the spectrum of the interference light between the light returned from the...
Comparative study of clinical indication-based DRLs with anatomical region-based DRLs in adult patients CT-scans in Yaounde - Cameroon.
Comparative study of clinical indication-based DRLs with anatomical region-based DRLs in adult patients CT-scans in Yaounde - Cameroon.
Background : CT-scan is the major source of population exposure in diagnostic x-rays radiology. DRLs is one of the main optimization tools, initially established by anatomical regi...
Design and Implementation of Matryoshka-type Neutron Spectrometer
Design and Implementation of Matryoshka-type Neutron Spectrometer
Abstract Aiming at portability and mobility, the design and implementation of a portable neutron spectrometer, namely the Matryoshka-type Neutron Spectrometer, was comple...
An Ultra-Portable Vis-NIR Spectrometer with an Integrated Light Source for Quality Analysis of Food and Agricultural Produce
An Ultra-Portable Vis-NIR Spectrometer with an Integrated Light Source for Quality Analysis of Food and Agricultural Produce
There is a growing demand for on-site quality analysis of food and agricultural produce along with detection of adulterants for selecting quality produce. Traditional laboratory me...
Polarized positron sources for the future linear colliders
Polarized positron sources for the future linear colliders
Sources de positrons polarisés pour les futurs collisionneurs linéaires Au cours des prochaines années les expériences au grand collisionneur de hadrons (LHC) au CE...

Back to Top