Energy and cooling performance of carbon-dioxide and hydrofluoroolefins blends as eco-friendly substitutes for R410A in air-conditioning systems
View through CrossRef
Air-conditioning and refrigeration systems are electrical appliances that use a huge amount of energy and contribute indirectly to global warming. Also, R410A which was initially developed as a substitute for ozone-depleting refrigerants in the air-conditioning systems has been phase-out due to its high global warming potential (GWP) and the resulting harmful effect on the climate. In addition to the issue of refrigerant high GWP, energy consumption is a significant issue. The energy efficiency of new refrigerants must then be considered in the search for alternative refrigerants to ensure that they do not lead to an increase in greenhouse gas generation at the power source. Therefore, this paper investigates the energy and cooling performance of four new multi-components and ecologically friendly refrigerant blends that contained carbon dioxide and hydrofluoroolefins in their compositions as substitutes for R410A in air-conditioning systems. Relevant thermodynamic equations and REFPROP software were employed for the computational analysis. The results indicated that the new blends (R445A, R455A, R470B and R470A) exhibited a desirable low compression ratio and high heat transfer for cooling applications. The blends also exhibited low compressor energy input and low specific cooling energy. R455A has an average coefficient of performance (COP) of 24.6% above that of the reference refrigerant (R410A). The cooling capacity per unit volume for R470B, R455A and R470A across a temperature range of 253 to 293 K are higher by 1.3, 6.0, and 12.6%, respectively than that of R410A. Generally, among all the four new substitute blends, the overall assessment revealed R455A as the best replacement for R410A in air-conditioning systems due to its superior performance in terms of its low compression ratio, compressor energy and specific cooling energy. R455A also has the highest COP and relatively high cooling capacity per unit volume.
Universitas Muhammadiyah Magelang
Title: Energy and cooling performance of carbon-dioxide and hydrofluoroolefins blends as eco-friendly substitutes for R410A in air-conditioning systems
Description:
Air-conditioning and refrigeration systems are electrical appliances that use a huge amount of energy and contribute indirectly to global warming.
Also, R410A which was initially developed as a substitute for ozone-depleting refrigerants in the air-conditioning systems has been phase-out due to its high global warming potential (GWP) and the resulting harmful effect on the climate.
In addition to the issue of refrigerant high GWP, energy consumption is a significant issue.
The energy efficiency of new refrigerants must then be considered in the search for alternative refrigerants to ensure that they do not lead to an increase in greenhouse gas generation at the power source.
Therefore, this paper investigates the energy and cooling performance of four new multi-components and ecologically friendly refrigerant blends that contained carbon dioxide and hydrofluoroolefins in their compositions as substitutes for R410A in air-conditioning systems.
Relevant thermodynamic equations and REFPROP software were employed for the computational analysis.
The results indicated that the new blends (R445A, R455A, R470B and R470A) exhibited a desirable low compression ratio and high heat transfer for cooling applications.
The blends also exhibited low compressor energy input and low specific cooling energy.
R455A has an average coefficient of performance (COP) of 24.
6% above that of the reference refrigerant (R410A).
The cooling capacity per unit volume for R470B, R455A and R470A across a temperature range of 253 to 293 K are higher by 1.
3, 6.
0, and 12.
6%, respectively than that of R410A.
Generally, among all the four new substitute blends, the overall assessment revealed R455A as the best replacement for R410A in air-conditioning systems due to its superior performance in terms of its low compression ratio, compressor energy and specific cooling energy.
R455A also has the highest COP and relatively high cooling capacity per unit volume.
Related Results
A comparative study of the flow boiling heat transfer characteristics of R410A and its alternative R447A in a horizontal smooth tube
A comparative study of the flow boiling heat transfer characteristics of R410A and its alternative R447A in a horizontal smooth tube
The ternary mixture R447A is an ideal substitute of R410A due to its low
global warming potential (GWP) and similar physical properties with
R410A. In this paper, the flow-boiling ...
Experimental Study of Performance Analysis of Split Air Conditioning Unit by Replacing Refrigerant R410A with R32 and R290
Experimental Study of Performance Analysis of Split Air Conditioning Unit by Replacing Refrigerant R410A with R32 and R290
The world phasedown of high global warming potential (GWP) refrigerants has created a need for low-GWP replacements that have equal or better performance in air conditioning system...
Co-benefits of efficient and climate friendly cooling in China
Co-benefits of efficient and climate friendly cooling in China
The cooling sector plays a pivotal role in the global economy but significantly contributes to global warming. In 2022, cooling-related emissions accounted for 13% of global greenh...
Unpacking contemporary English blends: Morphological structure, meaning, processing
Unpacking contemporary English blends: Morphological structure, meaning, processing
<p>It is not coincidental that blend words (e. g. nutriceutical ← nutricious + pharmaceutical, blizzaster ← blizzard + disaster) are more and more often used in media sources...
Laboratory tests of a prototype carbon dioxide ground-source air conditioner
Laboratory tests of a prototype carbon dioxide ground-source air conditioner
Environmental concerns are driving regulations to reduce the use of hydrofluorocarbons (HFCs) with high global warming potential (GWP) as refrigerants in heat pumps. CO2 is an attr...
Physical Property Calculation and Refrigeration Cycle Analysis of Mixed Refrigerant R32/R290
Physical Property Calculation and Refrigeration Cycle Analysis of Mixed Refrigerant R32/R290
The adoption of eco-friendly refrigerants in air conditioning systems is crucial for advancing low-carbon architecture. The current refrigerant R410A, with its high global warming ...
Architecture and adaptation
Architecture and adaptation
«The architectural work transcends the architect, goes beyond the moment in which its construction takes place, and therefore can be contemplated under the changing lights of histo...
Analysis of the dielectric properties of R410A Gas as an alternative to SF
6
for high‐voltage applications
Analysis of the dielectric properties of R410A Gas as an alternative to SF
6
for high‐voltage applications
Electric power industry is extensively using gas‐insulated systems for the transmission and distribution of electrical energy. In high‐voltage technology, the gas insulation is dom...