Enhanced red and near infrared detection in flow cytometry using avalanche photodiodes

View through CrossRef
AbstractPolychromatic flow cytometry enables detailed identification of cell phenotype using multiple fluorescent parameters. The photomultiplier tubes (PMTs) used to detect fluorescence in current instruments limit the sensitivity in the long wavelength spectral range. We demonstrate the flow cytometric applications of silicon avalanche photodiodes (APDs), which have improved red sensitivity and a working fluorescence detection range beyond 1,000 nm. A comparison of the wavelength‐dependent performance of the APD and PMT was carried out using pulsed light‐emitting diode sources, calibrated test beads, and biological samples. A breadboard flow cytometer test bench was constructed to compare the performance of PMTs and APD detectors. The APD used an additional amplifier stage to match the internal gain of the PMT. The resolution of the APD and PMT was compared for flow cytometry applications using a pulsed light‐emitting diode source over the 500–1060 nm spectral range. These measurements showed the relative changes in the signal‐to‐noise performance of the APD and PMT over a broad spectral range. Both the APD and PMTs were used to measure the signal‐to‐noise response for a set of six peak calibration beads over the 530–800 nm wavelength range. CD4‐positive cells labeled with antibody‐conjugated phycoerythrin or 800 nm quantum dots were identified by simultaneous detection using the APD and the PMT. The ratios of the intensities of the CD4− and CD4+ populations were found to be similar for both detectors in the visible wavelengths, but only the APD was able to separate these populations at wavelengths above 800 nm. These measurements illustrate the differences in APD and PMT performance at different wavelengths and signal intensity levels. While the APD and PMT show similar signal‐to‐noise performance in the visible spectral range, the dark noise of the APD detector reduces the sensitivity at low signal levels. At wavelengths longer than 650 nm, the high quantum efficiency of the APD contributes to better signal‐to‐noise performance. The APD detector provides enhanced performance in the long wavelength region and may be used to extend the working range of the flow cytometer beyond 1,000 nm. © 2008 International Society for Advancement of Cytometry
Title: Enhanced red and near infrared detection in flow cytometry using avalanche photodiodes
Description:
AbstractPolychromatic flow cytometry enables detailed identification of cell phenotype using multiple fluorescent parameters.
The photomultiplier tubes (PMTs) used to detect fluorescence in current instruments limit the sensitivity in the long wavelength spectral range.
We demonstrate the flow cytometric applications of silicon avalanche photodiodes (APDs), which have improved red sensitivity and a working fluorescence detection range beyond 1,000 nm.
A comparison of the wavelength‐dependent performance of the APD and PMT was carried out using pulsed light‐emitting diode sources, calibrated test beads, and biological samples.
A breadboard flow cytometer test bench was constructed to compare the performance of PMTs and APD detectors.
The APD used an additional amplifier stage to match the internal gain of the PMT.
The resolution of the APD and PMT was compared for flow cytometry applications using a pulsed light‐emitting diode source over the 500–1060 nm spectral range.
These measurements showed the relative changes in the signal‐to‐noise performance of the APD and PMT over a broad spectral range.
Both the APD and PMTs were used to measure the signal‐to‐noise response for a set of six peak calibration beads over the 530–800 nm wavelength range.
CD4‐positive cells labeled with antibody‐conjugated phycoerythrin or 800 nm quantum dots were identified by simultaneous detection using the APD and the PMT.
The ratios of the intensities of the CD4− and CD4+ populations were found to be similar for both detectors in the visible wavelengths, but only the APD was able to separate these populations at wavelengths above 800 nm.
These measurements illustrate the differences in APD and PMT performance at different wavelengths and signal intensity levels.
While the APD and PMT show similar signal‐to‐noise performance in the visible spectral range, the dark noise of the APD detector reduces the sensitivity at low signal levels.
At wavelengths longer than 650 nm, the high quantum efficiency of the APD contributes to better signal‐to‐noise performance.
The APD detector provides enhanced performance in the long wavelength region and may be used to extend the working range of the flow cytometer beyond 1,000 nm.
© 2008 International Society for Advancement of Cytometry.

Related Results

Singenetic Avalanche In The Ukrainian Carpathians
Singenetic Avalanche In The Ukrainian Carpathians
Purpose. Study of natural conditions of formation and passage of avalanche situation until the avalanche’s going within the North-Eastern macro-slope of Chorohora and Borzhava land...
Near-field observations of snow-avalanches propagating over a fiber-optic array
Near-field observations of snow-avalanches propagating over a fiber-optic array
<p>We present and evaluate array processing techniques and algorithms for the characterization of snow avalanche signals recorded with Distributed Acoustic Sensing (D...
Dynamics of the deadly snow avalanche of January 18, 2017 at Rigopiano (Central Italy)
Dynamics of the deadly snow avalanche of January 18, 2017 at Rigopiano (Central Italy)
On January 2017, a snow avalanche devastated a Resort-hotel in the municipality of Rigopiano in Abruzzo (Central Italy), unfortunately, burying alive 40 people. In a dramatic rescu...
Développement de photodiodes InGaAs petit pas pixel pour la détection du SWIR
Développement de photodiodes InGaAs petit pas pixel pour la détection du SWIR
Dans le contexte actuel où l’utilisation des capteurs d’image est en pleine croissance et diversification, ce travail de thèse porte sur le développement d’un capteur d’image petit...
Avalanche flow regime transitions in a changing climate
Avalanche flow regime transitions in a changing climate
<p>In the near future, climate change will impact the snow cover in Alpine regions. Higher precipitations and warmer temperatures are expected at lower altitude, lead...
Non-climatic factors affecting glacier mass balance (on the example of avalanche nourishment)
Non-climatic factors affecting glacier mass balance (on the example of avalanche nourishment)
<p>Glacier mass balance is affected by non-climatic factors such as topography, debris cover and geometric parameters of glaciers themselves, avalanche activity, volc...

Back to Top