Modeling of the Radiological Behavior During LOCA in Open Pool Type Reactor

View through CrossRef
This study aims to model the radiological consequences that result from loss of coolant accident in open pool research reactor of 22 MW power. The loss of coolant accident results from rupture in the cooling systems of the reactor and consequently results in decreasing the water level in the reactor pool. Decreasing the water level, that represents the shielding material above the reactor core, results in increasing the dose rate in the top region in the reactor pool as well as the reactor building. LOCA normally results in shutting down the reactor due to the radioprotection system provided in the upper region of the reactor pool. A failure in shutdown systems of the reactor during LOCA is rare but expected and it represents the worst case. So, evaluating LOCA from the radiological point of view must be investigated for the safe shutdown mode as well as the failure of shutdown case. The study also includes occurring LOCA for shutdown reactor taking the decay time into consideration. <br><br>ORIGEN-S module from scale system was used to estimate the delayed neutrons and gamma rays from the core for the shutdown mode. KENO-VI module from Scale system was used to estimate the prompt neutrons and gamma rays generated from the core for the failure case. Then, MAVRIC/Scale module was used to estimate the dose rate at the top point of the reactor pool for the two cases during LOCA.<br><br>Studying the dose rate during LOCA aims to determine the water level that verifies the radiological safety limit at the top point of the reactor pool for the two cases. The calculations introduced a relationship between the water level that verifies the permissible radiological limit (WL) and the decay time (DT) in the range between 0 to 30 d.
Elsevier BV
Title: Modeling of the Radiological Behavior During LOCA in Open Pool Type Reactor
Description:
This study aims to model the radiological consequences that result from loss of coolant accident in open pool research reactor of 22 MW power.
The loss of coolant accident results from rupture in the cooling systems of the reactor and consequently results in decreasing the water level in the reactor pool.
Decreasing the water level, that represents the shielding material above the reactor core, results in increasing the dose rate in the top region in the reactor pool as well as the reactor building.
LOCA normally results in shutting down the reactor due to the radioprotection system provided in the upper region of the reactor pool.
A failure in shutdown systems of the reactor during LOCA is rare but expected and it represents the worst case.
So, evaluating LOCA from the radiological point of view must be investigated for the safe shutdown mode as well as the failure of shutdown case.
The study also includes occurring LOCA for shutdown reactor taking the decay time into consideration.
<br><br>ORIGEN-S module from scale system was used to estimate the delayed neutrons and gamma rays from the core for the shutdown mode.
KENO-VI module from Scale system was used to estimate the prompt neutrons and gamma rays generated from the core for the failure case.
Then, MAVRIC/Scale module was used to estimate the dose rate at the top point of the reactor pool for the two cases during LOCA.
<br><br>Studying the dose rate during LOCA aims to determine the water level that verifies the radiological safety limit at the top point of the reactor pool for the two cases.
The calculations introduced a relationship between the water level that verifies the permissible radiological limit (WL) and the decay time (DT) in the range between 0 to 30 d.

Related Results

ANALISIS KONDISI TERAS REAKTOR DAYA MAJU AP1000 PADA KECELAKAAN SMALL BREAK LOCA
ANALISIS KONDISI TERAS REAKTOR DAYA MAJU AP1000 PADA KECELAKAAN SMALL BREAK LOCA
ABSTRAK ANALISIS KONDISI TERAS REAKTOR DAYA MAJU AP1000 PADA KECELAKAAN SMALL BREAK LOCA. Kecelakaan yang diakibatkan oleh kehilangan pendingin (loss of coolant accident / LOCA) da...
PARAMETRIC STUDY OF LOCA IN TRIGA-2000 USING RELAP5/SCDAP CODE
PARAMETRIC STUDY OF LOCA IN TRIGA-2000 USING RELAP5/SCDAP CODE
A postulated loss of coolant accident (LOCA) shall be analyzed to assure the safety of a research reactor. The analysis of such accident could be performed using best estimate ther...
ANALISIS PENGATURAN POSISI CONTROL RODS PADA KONSEP REAKTOR DAYA EKSPERIMENTAL INDONESIA PASCA REACTOR SCRAM
ANALISIS PENGATURAN POSISI CONTROL RODS PADA KONSEP REAKTOR DAYA EKSPERIMENTAL INDONESIA PASCA REACTOR SCRAM
ANALISISPENGATURAN POSISI CONTROL RODS PADA KONSEP REAKTOR DAYA EKSPERIMENTAL INDONESIA PASCA REACTOR SCRAM POST REACTOR SCRAM CONTROL RODS POSITION ADJUSTMENT ANALYSIS FOR THE IN...
Eliminación biológica de nutrientes en un ARU de baja carga orgánica mediante el proceso VIP
Eliminación biológica de nutrientes en un ARU de baja carga orgánica mediante el proceso VIP
El objetivo principal de esta tesis doctoral es profundizar en el conocimiento de los procesos biológicos responsables de la eliminación simultánea de nitrógeno y fósforo en un ARU...
Reservoir Characterization and Simulation of the Kisbey Frobisher-Alida Pool in Southeast Saskatchewan
Reservoir Characterization and Simulation of the Kisbey Frobisher-Alida Pool in Southeast Saskatchewan
Abstract The Kisbey Frobisher-Alida pool, located in southeast Saskatchewan, was discovered in 1985. The pool consists of multi-layer complex geology, with the Ki...
Development of New MHI LOCA Analysis Code: MCOBRA/RELAP5-GOTHIC
Development of New MHI LOCA Analysis Code: MCOBRA/RELAP5-GOTHIC
Mitsubishi Heavy Industries, Ltd. (MHI) has developed the safety analysis code system, MCOBRA/RELAP5-GOTHIC, for large break LOCA, small break LOCA and containment integrity analys...
Multidimensional Reveal of Nitrogen Regulation on Comammox
Multidimensional Reveal of Nitrogen Regulation on Comammox
Abstract Background The discovery of complete ammonia oxidizer (comammox) was groundbreaking. Comammox can use ammonia as the sole nitrogen source and turn it to nitrate. M...
Seismic Application in Horizontal Well Drilling - Brazeau River Nisku D Pool
Seismic Application in Horizontal Well Drilling - Brazeau River Nisku D Pool
Abstract Since 1992, two 300–400 m long horizontal wells have been drilled in the Brazeau River Nisku D pool at a true vertical depth of 3200 m. The pool has been...

Back to Top