Formaldehyde monitoring in office buildings located in tropical climates of India

View through CrossRef
Abstract Indoor air pollution is a result of complex phenomenon that occurs due to constantly changing interaction of various indoor and outdoor environmental factors. Volatile Organic Compounds (VOCs) are the major pollutants in air conditioned indoors, perhaps having a large subset of hazardous compounds. In this study, formaldehyde (HCHO) was monitored at 30 minute interval using portable photoelectric absorptiometric sensors along with comfort parameters like air temperature, relative humidity and air flow rate at six newly constructed or renovated office buildings located in composite, temperate and warm-humid climatic zones (in various parts of India). Results show that formaldehyde emissions exceeded the limits suggested by LEED guidelines (27 ppb) in all the buildings except in the ones where low emitting green interiors were used. Furniture and interior decorative work were found to be the primary sources of formaldehyde emission than other parameters. A logarithmic relationship (R2=0.65) was established between HCHO and respective age of the building/refurbished time. The analysis also presents that in a scenario of green interiors (low HCHO concentration) and the humidity levels above 60%, the trend of HCHO concentration with indoor moisture exhibits certain time delays in reaching equilibrium due to slow conditioning of HCHO molecules and indoor moisture. The study provides a rational analysis on HCHO emissions in Indian office buildings, which is important to understand possible sources and their effects on HCHO concentration in office indoors. The study data helps to implement required measures to control indoor humidity levels or necessary HCHO mitigation strategies during design and operation process of the air-conditioned office buildings.
Title: Formaldehyde monitoring in office buildings located in tropical climates of India
Description:
Abstract Indoor air pollution is a result of complex phenomenon that occurs due to constantly changing interaction of various indoor and outdoor environmental factors.
Volatile Organic Compounds (VOCs) are the major pollutants in air conditioned indoors, perhaps having a large subset of hazardous compounds.
In this study, formaldehyde (HCHO) was monitored at 30 minute interval using portable photoelectric absorptiometric sensors along with comfort parameters like air temperature, relative humidity and air flow rate at six newly constructed or renovated office buildings located in composite, temperate and warm-humid climatic zones (in various parts of India).
Results show that formaldehyde emissions exceeded the limits suggested by LEED guidelines (27 ppb) in all the buildings except in the ones where low emitting green interiors were used.
Furniture and interior decorative work were found to be the primary sources of formaldehyde emission than other parameters.
A logarithmic relationship (R2=0.
65) was established between HCHO and respective age of the building/refurbished time.
The analysis also presents that in a scenario of green interiors (low HCHO concentration) and the humidity levels above 60%, the trend of HCHO concentration with indoor moisture exhibits certain time delays in reaching equilibrium due to slow conditioning of HCHO molecules and indoor moisture.
The study provides a rational analysis on HCHO emissions in Indian office buildings, which is important to understand possible sources and their effects on HCHO concentration in office indoors.
The study data helps to implement required measures to control indoor humidity levels or necessary HCHO mitigation strategies during design and operation process of the air-conditioned office buildings.

Related Results

Sustainable High-rises
Sustainable High-rises
With the aim to limit the number of ineffective designs, this dissertation has investigated the impact of architectural design strategies on improving the energy performance of and...
Hidden formaldehyde in cosmetic products
Hidden formaldehyde in cosmetic products
AbstractBackgroundFormaldehyde is a common cause of contact allergy. Hidden formaldehyde, that is, formaldehyde in products without formaldehyde releasers, has previously been dete...
Assessing energy rating premiums in the performance of green office buildings in Australia
Assessing energy rating premiums in the performance of green office buildings in Australia
Purpose– Green office buildings have recently taken on increased significance in institutional property portfolios in Australia and globally. The key issue from an institutional in...
Freshness and Contamination with Formalin of Mackerel marketed in Dar es Salaam
Freshness and Contamination with Formalin of Mackerel marketed in Dar es Salaam
Abstract Background Fish constitutes a nutritious food that deteriorates quickly when poorly preserved. Several biochemicals, including formaldehyde, naturally accumulate i...
Fabrication and excellent formaldehyde Gas sensing properties of Yb-doped In2O3 nanotubes
Fabrication and excellent formaldehyde Gas sensing properties of Yb-doped In2O3 nanotubes
Pure and Yb-doped In2O3 nanotubes have been successfully fabricated by using the single-capillary electrospinning method, followed by calcination. The morphological and structural ...
Formaldehyde Exposure and Human Health Risks
Formaldehyde Exposure and Human Health Risks
Abstract This chapter primarily focuses on the human health effects of formaldehyde inhalation exposure. It summarizes significant published findings and recently...
Current Perspectives on Cystic Echinococcosis: A Systematic Review
Current Perspectives on Cystic Echinococcosis: A Systematic Review
Abstract Introduction: Hydatidosis, a zoonotic disease caused by the larval stage of Echinococcus granulosus, is a significant public health concern with notable economic impact. I...

Back to Top