Determination of free formaldehyde in cosmetics products through derivatization with 2,4-DNPH using an optimized and validated HPLC-PDA method

View through CrossRef
AbstractFormaldehyde plays a significant role in the global economy due to its unique chemical properties and widespread use in both the medical field and various industrial sectors. However, formaldehyde (HCHO) is classified as a persistent organic pollutant and is known to be harmful. Exposure to formaldehyde, both direct and prolonged, can cause severe health issues and potentially lead to death. It is recognized as a human carcinogen by numerous organizations and can negatively impact the endocrine system, as well as having mutagenic or teratogenic effects. Formaldehyde has been detected in various matrices at levels exceeding those permitted by international health regulatory bodies. Chromatography, particularly high-performance liquid chromatography (HPLC) coupled with detection methods, is an analytical technique frequently used to determine volatile organic molecules, including formaldehyde. This investigation aimed to develop and validate an assay method to identify and quantify formaldehyde in cosmetic products using HPLC-PDA. The chosen isocratic system consisted of a ZORBAX RX-C8 column (250 mm × 4.6 mm; 5 μm) and a mobile phase mixture of acetonitrile and water in a 55:45 (v/v) ratio, with a flow rate of 1.5 mL min−1. Formaldehyde was detected at 353 nm after derivatization with a 0.1N 2,4-dinitrophenylhydrazine solution, with a retention time of approximately 5.0 min and a total run time of 7.0 min for formaldehyde. The method was validated according to ICH Q2 (R1) guidelines. The validation parameters demonstrated high selectivity, precision (RSD <2%), accuracy (mean recovery of 101.3%), linearity (r > 0.995 in the 1,000–2,400 ppm range), and a limit of quantification (LOQ) of 0.1 ppm. The validated analytical method was applied to 35 cosmetic products. None of these products were labeled as containing formaldehyde, although 6 imported products were labeled as containing formaldehyde-releasing preservatives. The results indicated that 88.6% of the samples tested positive for formaldehyde, with free formaldehyde levels ranging from 20 to 981 ppm. All samples contained formaldehyde levels below the 2000 ppm threshold.
Title: Determination of free formaldehyde in cosmetics products through derivatization with 2,4-DNPH using an optimized and validated HPLC-PDA method
Description:
AbstractFormaldehyde plays a significant role in the global economy due to its unique chemical properties and widespread use in both the medical field and various industrial sectors.
However, formaldehyde (HCHO) is classified as a persistent organic pollutant and is known to be harmful.
Exposure to formaldehyde, both direct and prolonged, can cause severe health issues and potentially lead to death.
It is recognized as a human carcinogen by numerous organizations and can negatively impact the endocrine system, as well as having mutagenic or teratogenic effects.
Formaldehyde has been detected in various matrices at levels exceeding those permitted by international health regulatory bodies.
Chromatography, particularly high-performance liquid chromatography (HPLC) coupled with detection methods, is an analytical technique frequently used to determine volatile organic molecules, including formaldehyde.
This investigation aimed to develop and validate an assay method to identify and quantify formaldehyde in cosmetic products using HPLC-PDA.
The chosen isocratic system consisted of a ZORBAX RX-C8 column (250 mm × 4.
6 mm; 5 μm) and a mobile phase mixture of acetonitrile and water in a 55:45 (v/v) ratio, with a flow rate of 1.
5 mL min−1.
Formaldehyde was detected at 353 nm after derivatization with a 0.
1N 2,4-dinitrophenylhydrazine solution, with a retention time of approximately 5.
0 min and a total run time of 7.
0 min for formaldehyde.
The method was validated according to ICH Q2 (R1) guidelines.
The validation parameters demonstrated high selectivity, precision (RSD <2%), accuracy (mean recovery of 101.
3%), linearity (r > 0.
995 in the 1,000–2,400 ppm range), and a limit of quantification (LOQ) of 0.
1 ppm.
The validated analytical method was applied to 35 cosmetic products.
None of these products were labeled as containing formaldehyde, although 6 imported products were labeled as containing formaldehyde-releasing preservatives.
The results indicated that 88.
6% of the samples tested positive for formaldehyde, with free formaldehyde levels ranging from 20 to 981 ppm.
All samples contained formaldehyde levels below the 2000 ppm threshold.

Related Results

Hidden formaldehyde in cosmetic products
Hidden formaldehyde in cosmetic products
AbstractBackgroundFormaldehyde is a common cause of contact allergy. Hidden formaldehyde, that is, formaldehyde in products without formaldehyde releasers, has previously been dete...
The development of a novel universal coating for urological implants
The development of a novel universal coating for urological implants
Urology employs various implants, such as urinary catheters, ureteral stents, and ureteral access sheaths (UASs), to manage diseases associated with the urinary tract system. These...
Patent Ductus Arteriosus Response to Treatment by Course and Associations with Perinatal and Clinical Factors
Patent Ductus Arteriosus Response to Treatment by Course and Associations with Perinatal and Clinical Factors
Objective The objective of this study is to examine patent ductus arteriosus (PDA) response by treatment course and investigate associations with postmenstrual age (PMA), chronolog...
Freshness and Contamination with Formalin of Mackerel marketed in Dar es Salaam
Freshness and Contamination with Formalin of Mackerel marketed in Dar es Salaam
Abstract Background Fish constitutes a nutritious food that deteriorates quickly when poorly preserved. Several biochemicals, including formaldehyde, naturally accumulate i...
Formaldehyde Exposure and Human Health Risks
Formaldehyde Exposure and Human Health Risks
Abstract This chapter primarily focuses on the human health effects of formaldehyde inhalation exposure. It summarizes significant published findings and recently...
Investigation of Gentamicin Release from Polydopamine Nanoparticles
Investigation of Gentamicin Release from Polydopamine Nanoparticles
Polydopamine (PDA), being highly reactive in nature, has acquired great attention in multi-disciplinary fields. Owing to its fascinating properties, including its biocompatible, no...
Fabrication and excellent formaldehyde Gas sensing properties of Yb-doped In2O3 nanotubes
Fabrication and excellent formaldehyde Gas sensing properties of Yb-doped In2O3 nanotubes
Pure and Yb-doped In2O3 nanotubes have been successfully fabricated by using the single-capillary electrospinning method, followed by calcination. The morphological and structural ...

Back to Top