Javascript must be enabled to continue!
Deposition of poly(diphenylamine‐co‐o‐chloroaniline) by pulse potentiostatic method: Growth equation and characterization
View through CrossRef
AbstractElectrochemical copolymerization of diphenylamine (DPA) with o‐chloroaniline (OCA) was performed in aqueous 4M sulfuric acid using the pulse potentiostatic method (PPSM). By employing the tunable parameters in PPSM, polymeric films were deposited under different conditions. Cyclic voltammetry was used for evaluating the characteristics of the deposited polymeric films. A suitable growth equation for the deposition of polymer, relating the charge associated for the film deposition and the pulse parameters in PPSM, was deduced. Various surface parameters are evaluated. The formation of copolymer during PPSM deposition was revealed through critical analysis of the results. The characteristic differences between the individual homopolymers, poly(diphenylamine) and poly(o‐chloroaniline) and the copolymer, poly(diphenylamine‐co‐o‐chloroaniline), were brought out. The copolymer was also synthesized through a chemical method and characterized through infrared and ultraviolet‐visible spectroscopic analysis. © 2003 Wiley Periodicals, Inc. J Appl Polym Sci 88: 389–397, 2003
Title: Deposition of poly(diphenylamine‐co‐o‐chloroaniline) by pulse potentiostatic method: Growth equation and characterization
Description:
AbstractElectrochemical copolymerization of diphenylamine (DPA) with o‐chloroaniline (OCA) was performed in aqueous 4M sulfuric acid using the pulse potentiostatic method (PPSM).
By employing the tunable parameters in PPSM, polymeric films were deposited under different conditions.
Cyclic voltammetry was used for evaluating the characteristics of the deposited polymeric films.
A suitable growth equation for the deposition of polymer, relating the charge associated for the film deposition and the pulse parameters in PPSM, was deduced.
Various surface parameters are evaluated.
The formation of copolymer during PPSM deposition was revealed through critical analysis of the results.
The characteristic differences between the individual homopolymers, poly(diphenylamine) and poly(o‐chloroaniline) and the copolymer, poly(diphenylamine‐co‐o‐chloroaniline), were brought out.
The copolymer was also synthesized through a chemical method and characterized through infrared and ultraviolet‐visible spectroscopic analysis.
© 2003 Wiley Periodicals, Inc.
J Appl Polym Sci 88: 389–397, 2003.
Related Results
Macroeconomic and Social Precursors of Suicide Rates in the Philippines: A Quantitative Analysis (Preprint)
Macroeconomic and Social Precursors of Suicide Rates in the Philippines: A Quantitative Analysis (Preprint)
BACKGROUND
Suicide is a complex, serious and multifaceted public health issue that poses significant challenges to societies worldwide. In fact, it represen...
Poly(2-chloroaniline) and poly(aniline-co-2-chloroaniline) films on ZnFe alloy plating
Poly(2-chloroaniline) and poly(aniline-co-2-chloroaniline) films on ZnFe alloy plating
Purpose
The purpose of this paper is to evaluate and compare the protective, anticorrosion behaviors and electrochemically synthesis of poly(2-chloroaniline) (P...
The Potentiostatic Technique for Corrosion Studies
The Potentiostatic Technique for Corrosion Studies
Abstract
One of the most widely used electrochemical corrosion testing methods is the constant potential, or "potentiostatic," technique. This paper is designed as a...
Pulse Potential Deposition - an Experimental Protocol for Growth of High Quality Thin Films Via Surface Limited Red-Ox Replacement Reaction
Pulse Potential Deposition - an Experimental Protocol for Growth of High Quality Thin Films Via Surface Limited Red-Ox Replacement Reaction
Pulse Current Deposition method for growth of thin films and functional coatings has been in use in academia and industry for quite some time [[1]]. However, with few exemptions [[...
Pulse diagnostics of the Tibetan medical tradition: the experience of objectification of the basic principles of pulse diagnostics using a pulse diagnostic device.
Pulse diagnostics of the Tibetan medical tradition: the experience of objectification of the basic principles of pulse diagnostics using a pulse diagnostic device.
The study shows the experience of objectification of the basic characteristics of pulse waves in the diagnosis of the pulse of the Tibetan medical tradition. An experienced doctor ...
Helical Periodicity of DNA, Poly(dA)·Poly(dT) and Poly(dA‐dT)·Poly(dA‐dT) in Solution
Helical Periodicity of DNA, Poly(dA)·Poly(dT) and Poly(dA‐dT)·Poly(dA‐dT) in Solution
Helical periodicity of DNA, poly(dA)·poly(dT) and poly(dA‐dT)·poly(dA‐dT) has been measured in solution by using the band shift method of Wang [Wang, J. (1979) Proc. Natl Acad. Sci...
Pulse selection algorithm for NM64 neutron detector
Pulse selection algorithm for NM64 neutron detector
Abstract
We propose an algorithm to sepearate pile-up pulses in neutron detectors by utilizing a standard pulse. For this method to be effective, the data must consi...
Preparation, optimization, and modification of urea‐formaldehyde resin for used as a plugging agent in fractured and caved oil and gas reservoirs
Preparation, optimization, and modification of urea‐formaldehyde resin for used as a plugging agent in fractured and caved oil and gas reservoirs
AbstractBased on the requirements of resin‐based plugging agents on initial viscosity, gel time and cost, the urea‐formaldehyde resin Poly‐UF was synthesized via aqueous solution p...

