Javascript must be enabled to continue!
Integrated electrical modeling of circulating tumor cells for enhanced dielectrophoretic trapping and electroporation
View through CrossRef
Abstract
This study presents a comprehensive computational and experimental investigation of the integrated dielectrophoresis (DEP) and electroporation framework for the selective manipulation and controlled treatment of circulating tumor cells (CTCs), white blood cells (WBCs), and platelets (PLTs) within a unified microfluidic platform. A multiphysics mathematical model, implemented in COMSOL Multiphysics, is developed to simulate the complete sequence of DEP-driven cell trapping followed by pulsed electric field electroporation, capturing the dynamic processes of membrane charging, pore nucleation, growth, and resealing under short-duration 2 µs electric pulses. The key electroporation parameters, including transmembrane potential, pore radius, pore density, and membrane conductivity, are systematically characterized for each cell type to define cell-specific optimal pulse protocols that maximize treatment efficacy while preserving cell viability and minimizing thermal effects. The DEP mechanism provides stable spatial confinement of target cells between electrode pairs, enabling precise and reproducible exposure to calibrated electric fields with reduced off-target perturbations. Comparative computational analysis across the three cell types reveals that the requisite electric field strength must be tailored to cell dimensions, with 1–4 kV/cm identified as appropriate for CTCs and WBCs and 10–40 kV/cm required for platelets owing to their substantially smaller diameter and correspondingly higher membrane charging threshold. The simulation results demonstrate spatially heterogeneous pore dynamics and electric displacement field distributions across the cell membrane, with the most pronounced effects concentrated at the hyperpolarized pole, underscoring the critical influence of cell geometry and electric field distribution on electroporation outcomes. To experimentally validate the computational predictions, a dedicated microfluidic platform integrating microfabricated electrode arrays with real-time impedance sensing and optical monitoring was developed and applied to THP-1 monocytic cells as a representative model system. The device comprises a central impedance sensor defining the active sensing zone and surrounding focusing electrodes with lateral dimensions of
$$L = w = 600$$
µm and an inter-electrode spacing of 200 µm, electrically routed through via connections for independent excitation and measurement. Impedance spectroscopy was performed over a frequency range of
$$10^{3}$$
–
$$10^{6}$$
Hz under applied voltages from 1 to 25 V across the 200 µm sensing gap. The impedance magnitude (|
Z
|) exhibited a clear monotonic decrease with increasing applied voltage, with the most pronounced reductions observed in the mid-frequency range (10–100 kHz), confirming enhanced membrane permeability and increased effective conductivity of the cell suspension under stronger electric fields. The reactive impedance component (
$$X_s$$
) demonstrated progressive suppression of negative reactance with increasing voltage, indicating systematic loss of membrane capacitive behavior, while the series resistance (
$$R_s$$
) decreased and stabilized at higher voltages, reflecting a transition from capacitance-dominated to conductivity-dominated electrical transport.
Springer Science and Business Media LLC
Title: Integrated electrical modeling of circulating tumor cells for enhanced dielectrophoretic trapping and electroporation
Description:
Abstract
This study presents a comprehensive computational and experimental investigation of the integrated dielectrophoresis (DEP) and electroporation framework for the selective manipulation and controlled treatment of circulating tumor cells (CTCs), white blood cells (WBCs), and platelets (PLTs) within a unified microfluidic platform.
A multiphysics mathematical model, implemented in COMSOL Multiphysics, is developed to simulate the complete sequence of DEP-driven cell trapping followed by pulsed electric field electroporation, capturing the dynamic processes of membrane charging, pore nucleation, growth, and resealing under short-duration 2 µs electric pulses.
The key electroporation parameters, including transmembrane potential, pore radius, pore density, and membrane conductivity, are systematically characterized for each cell type to define cell-specific optimal pulse protocols that maximize treatment efficacy while preserving cell viability and minimizing thermal effects.
The DEP mechanism provides stable spatial confinement of target cells between electrode pairs, enabling precise and reproducible exposure to calibrated electric fields with reduced off-target perturbations.
Comparative computational analysis across the three cell types reveals that the requisite electric field strength must be tailored to cell dimensions, with 1–4 kV/cm identified as appropriate for CTCs and WBCs and 10–40 kV/cm required for platelets owing to their substantially smaller diameter and correspondingly higher membrane charging threshold.
The simulation results demonstrate spatially heterogeneous pore dynamics and electric displacement field distributions across the cell membrane, with the most pronounced effects concentrated at the hyperpolarized pole, underscoring the critical influence of cell geometry and electric field distribution on electroporation outcomes.
To experimentally validate the computational predictions, a dedicated microfluidic platform integrating microfabricated electrode arrays with real-time impedance sensing and optical monitoring was developed and applied to THP-1 monocytic cells as a representative model system.
The device comprises a central impedance sensor defining the active sensing zone and surrounding focusing electrodes with lateral dimensions of
$$L = w = 600$$
µm and an inter-electrode spacing of 200 µm, electrically routed through via connections for independent excitation and measurement.
Impedance spectroscopy was performed over a frequency range of
$$10^{3}$$
–
$$10^{6}$$
Hz under applied voltages from 1 to 25 V across the 200 µm sensing gap.
The impedance magnitude (|
Z
|) exhibited a clear monotonic decrease with increasing applied voltage, with the most pronounced reductions observed in the mid-frequency range (10–100 kHz), confirming enhanced membrane permeability and increased effective conductivity of the cell suspension under stronger electric fields.
The reactive impedance component (
$$X_s$$
) demonstrated progressive suppression of negative reactance with increasing voltage, indicating systematic loss of membrane capacitive behavior, while the series resistance (
$$R_s$$
) decreased and stabilized at higher voltages, reflecting a transition from capacitance-dominated to conductivity-dominated electrical transport.
Related Results
Complex Collision Tumors: A Systematic Review
Complex Collision Tumors: A Systematic Review
Abstract
Introduction: A collision tumor consists of two distinct neoplastic components located within the same organ, separated by stromal tissue, without histological intermixing...
Abstract 819: Investigating the impacts of membrane potential on nano-electroporation efficacy
Abstract 819: Investigating the impacts of membrane potential on nano-electroporation efficacy
Abstract
Electroporation has been shown to be an effective method of intracellular drug delivery and tissue ablation, however it faces significant challenges not onl...
EPD Electronic Pathogen Detection v1
EPD Electronic Pathogen Detection v1
Electronic pathogen detection (EPD) is a non - invasive, rapid, affordable, point- of- care test, for Covid 19 resulting from infection with SARS-CoV-2 virus. EPD scanning techno...
Supplementary Data from Targeted BiTE Expression by an Oncolytic Vector Augments Therapeutic Efficacy Against Solid Tumors
Supplementary Data from Targeted BiTE Expression by an Oncolytic Vector Augments Therapeutic Efficacy Against Solid Tumors
<p>Supplementary Methods, Supplementary Figures S1-S15 Fig. S1. Purification and binding specificity of MV-encoded BiTEs. (A) Purification of MV-expressed BiTEs. Vero cells w...
Giant Sacrococcygeal Teratoma in Infant: Systematic Review
Giant Sacrococcygeal Teratoma in Infant: Systematic Review
Abstract
Introduction
Sacrococcygeal teratoma (SCT) is a rare embryonal tumor that occurs in the sacrococcygeal region, with an incidence of about 1 in 35,000 to 40,000 live births...
Analytical Formulation of the Electric Field Induced by Electrode Arrays: Towards Automated Dielectrophoretic Cell Sorting
Analytical Formulation of the Electric Field Induced by Electrode Arrays: Towards Automated Dielectrophoretic Cell Sorting
Dielectrophoresis is defined as the motion of an electrically polarisable particle in a non-uniform electric field. Current dielectrophoretic devices enabling sorting of cells are ...
Comparison of Chemical and Hysteresis CO2 Trapping in the Nugget Formation
Comparison of Chemical and Hysteresis CO2 Trapping in the Nugget Formation
Abstract
The Moxa Arch Anticline is a regional-scale northwest-trending uplift in western Wyoming and it has been chosen for CO2 capture and storage. The Nugget Sand...
Optimizing the electroporation parameters forHeterometopus palaeformis (strain RAJCA) v1
Optimizing the electroporation parameters forHeterometopus palaeformis (strain RAJCA) v1
Cell viability after incubation with different electroporation buffers, Phosphate buffered saline (PBS) is used as an electroporation buffer for many eukaryotic cells. However, we...